Abstract
Over the past two decades there has been a substantial rise in the adoption of diabetes therapeutic technology among children, adolescents and younger adults with type 1 diabetes, and its use is now also advocated for older individuals. Older people with diabetes are more prone to experience hypoglycaemia because of numerous predisposing factors and are at higher risk of hypoglycaemic events requiring third-party assistance as well as other adverse sequelae. Hypoglycaemia may also have long-term consequences, including cognitive impairment, frailty and disability. Diabetes in older people is often characterised by marked glucose variability related to age-associated changes such as variable appetite and levels of physical activity, comorbidities and polypharmacotherapy. Preventing hypoglycaemia and mitigating glucose excursions may have considerable positive impacts on physical and cognitive function and general well-being and may even prevent or improve frailty. Technology for older people includes continuous glucose monitoring systems, insulin pumps, automated insulin delivery systems and smart insulin pens. Clinical trials and real-world studies have shown that older people with diabetes benefit from technology in terms of glucose management, reductions in hypoglycaemic events, emergency department attendance and hospital admissions, and improvement in quality of life. However, ageing may bring physical impairments and other challenges that hinder the use of technology. Healthcare professionals should identify older adults with diabetes who may benefit from therapeutic technology and then adopt an individualised approach to education and follow-up for individuals and their caregivers. Future research should explore the impact of diabetes technology on outcomes relevant to older people with diabetes.
Graphical Abstract
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
Diabetes prevalence is increasing worldwide, with global prevalence rates among people aged 65 years and above already exceeding 20%, and with the highest rate (~24%) observed in those aged 75–79 years [1, 2]. In the UK, over a quarter of people with type 1 diabetes and nearly three-quarters of people with type 2 diabetes are aged 60 years and above [3]. The number of older adults with type 1 diabetes is growing progressively due to a reduction in diabetes-related complications and increased life expectancy [4]. Many people with type 1 diabetes now live long healthy lives, even into their eighth decade and beyond [5].
Older adults with diabetes are more susceptible than younger people to recurrent hypoglycaemia and glucose excursions, which can accelerate physical and cognitive decline and increase the risk of adverse events [6]. Technology plays an important role in glucose management and avoidance of hypoglycaemia among older people with diabetes and also appears to improve quality of life and other health-related outcomes [7].
In this article, we review recent evidence on the benefits of available diabetes technology among older people, identify challenges related to its use, describe the assessment process for older people being considered for use of technology and, finally, highlight areas for future research in this field.
Hypoglycaemia in older people
Diabetes in older people is characterised by marked heterogeneity reflecting factors such as functional status, cognitive status, comorbidities, frailty, duration of diabetes, capacity for self-care, level of family/caregiver support and life expectancy [8]. Given these medical complexities, guidelines for diabetes in older people emphasise that treatment strategies and goals should be individualised following consideration of clinical, psychological, functional and social factors [9].
The ADA recommends glycaemic targets according to an individual’s health status, which can range from ‘healthy’ to ‘complex’ and ‘very complex’ [9]. The ADA also recommends ‘relaxed’ HbA1c targets for older people with a complex or very complex health status, in order to prevent hypoglycaemia [9]. However, HbA1c levels are not associated with hypoglycaemia risk in the older population with diabetes on insulin therapy, and less stringent HbA1c goals do not preclude the risk of hypoglycaemia [10].
As people with diabetes age, they become more prone to hypoglycaemia and their hypoglycaemia awareness may decline, putting them at risk of events requiring third-party assistance. Age per se, through impaired counter-regulatory responses and changes in pharmacokinetics and pharmacodynamics, contributes to the decline in hypoglycaemia awareness [11].
In older people, hypoglycaemia often presents with atypical symptoms, mimicking neurological conditions, or with disorientation or sudden behavioural changes [6] and is one of the most common causes of falls, fractures, cardiac arrythmias and emergency department and hospital attendances [11,12,13]. Unsurprisingly, the rate of annual hospitalisations due to hypoglycaemia in older people is estimated to be double that for younger individuals and this implies an economic burden for healthcare systems [6].
Recurrent hypoglycaemia is also emerging as a risk factor for geriatric syndromes (particularly cognitive impairment and depression) and appears to be associated with significant morbidity, frailty and disability [6]. The relationship between hypoglycaemia and cognitive impairment is well established and bidirectional. In turn, cognitive impairment in older people with diabetes is commonly associated with impaired awareness of hypoglycaemia and glucose variability. In a population-based prospective cohort study of 783 older people with diabetes, over the 12 year follow-up period, individuals who experienced a severe hypoglycaemia event were twice as likely to develop dementia, and individuals who developed dementia were three times more likely to have a subsequent severe hypoglycaemia event [12].
Hypoglycaemia also affects the quality of life of older people. Individuals who experience frequent hypoglycaemia or hypoglycaemia fear tend to avoid activities such as physical exercise and this worsens the feeling of anxiety and leads to social isolation [13]. Minimising the risk of and fear of hypoglycaemia is therefore a key aim in the management of diabetes in older people, in order to improve health-related outcomes and quality of life. However, relaxing HbA1c goals does not preclude the risk of hypoglycaemia and may worsen outcomes for older people with diabetes.
Glucose variability and risk of adverse clinical events
For decades, HbA1c has been the gold standard parameter for assessing glycaemic management in people with diabetes; however, it does not take into consideration excursions in blood glucose levels known as glucose variability, and in the older population may not reflect mean glucose levels equivalent to those for younger adults because of comorbidities that affect the lifespan of red blood cells [14, 15]. Thus, there are major shortcomings with using HbA1c as the sole parameter for measuring glycaemic goals in older people.
Glucose variability is receiving particular attention as a parameter for assessing glycaemic management as it can increase both the risk of hypoglycaemia and fluctuations in the hyperglycaemia range [16]. Several studies have shown that glucose variability has more deleterious effects than sustained hyperglycaemia in the development of diabetes-related complications and is associated with an increased risk of mortality [17, 18]. It is thought that glucose variability accelerates the ageing process and the progression of CVD through enhanced oxidative stress, low-grade inflammation and endothelial dysfunction [19, 20]. Attenuated glucose variability in the absence of diabetes has been linked to healthy ageing and longevity [21]. Compared with young adults with diabetes, older people with diabetes appear to have a higher degree of glucose variability, which predicts severe and nocturnal hypoglycaemia [22].
There are two types of glucose variability: (1) long-term glucose variability, based on serial measurements over a long period of time and involving HbA1c, serial fasting plasma and postprandial glucose measurements; and (2) short-term glucose variability, represented by within-day and between-day glucose variability [23]. The most popular metrics for glucose variability are the % CV, which is correlated with risk of hypoglycaemia, and the SD, which is highly correlated with most measures of glucose variability, including mean amplitude of glycaemic excursion, IQR, mean of daily differences and average daily risk range [23].
Table 1 describes the main studies that have examined the relationship between glucose variability and adverse events in older people with diabetes. In a study including 130 adults with type 1 diabetes aged ≥65 years, those with high glucose variability (>36% CV) spent more time in hypoglycaemia (both <3.9 and <3.0 mmol/l) than those with low glucose variability (≤36% CV; 84 vs 31 min/day, p<0.0001, and 46 vs 8 min/day, p<0.001, respectively). Importantly, when HbA1c was higher than the glucose management indicator, hypoglycaemia of longer duration was observed. % CV and the glucose management indicator are therefore better indicators for risk of hypoglycaemia than HbA1c [24].
There is a paucity of data on the effect of glucose variability on physical and cognitive function and frailty. Among people with type 2 diabetes, high glucose variability has been associated with cognitive impairment [25]. In the Taiwan diabetes study, visit-to-visit variations in fasting plasma glucose levels and HbA1c have been associated with Alzheimer’s disease [26]. Several studies have investigated the relationship between glucose variability and frailty. Chung et al divided 48 individuals with type 2 diabetes aged ≥65 years and using continuous glucose monitoring (CGM) into two groups: ‘healthy and pre-frail’ (n=24) and ‘frail’ (n=24). CGM was used for 6.9 days and the authors found higher CGM metrics (particularly post-lunch time above range) in the frail group (p<0.05) [27]. These findings may not reflect glucose variability per se as there were no differences between groups in % CV/mean amplitude of glycaemic excursion measurements. A study by Fung et al [28] showed a relationship between incremental frailty and increased dysglycaemia in older adults with type 2 diabetes on insulin, whereas Idrees et al demonstrated an association between frailty and hypoglycaemia in non-acute settings [29].
In older people, glucose variability can influence mortality risk. In a 5 year retrospective cohort study including data from 54,803 individuals aged ≥70 years with type 1 or type 2 diabetes, Forbes et al evaluated the effect of glucose variability on mortality risk by using a new metric for glucose variability and found that mortality risk increased with increasing glycaemic variability [30]. Ma et al explored the relationship between sarcopenia and glucose variability in a study including 280 individuals with type 2 diabetes aged ≥60 years who were divided into a sarcopenic group and a non-sarcopenic group and wore a continuous glucose monitor for 3 days [31]. The authors found lower prevalence of sarcopenia with higher time in range (TIR) values (40.48% for TIR≤50%, 20.41% for 50%<TIR≤70%, 8.47% for TIR>70%). However, parameters of glucose variability (CV, mean amplitude of glycaemic excursions) were not different between the two groups (CV p=0.872, mean amplitude of glycaemic excursions p=0.366) [31].
In another study, Zhang et al demonstrated that older people, when compared with middle-aged individuals, have a greater glucose variability which is associated with an increased risk of supraventricular and ventricular arrythmias [32]; these studies are described in Table 1.
Glucose variability can also impact individuals’ psychological well-being, whereas its attenuation can lead to improvements in quality of life [33].
In conclusion, the literature indicates that wide glucose variability is associated with negative health-related outcomes in older people with diabetes and its attenuation might positively impact quality of life and increase life expectancy.
Diabetes technology in older people
A key aim of current management approaches to diabetes in older people is to support them to achieve healthy glucose levels and minimise the risk of hypoglycaemia.
The use of technology by older people with diabetes is growing and has been shown to have a remarkable impact on their diabetes-related outcomes and quality of life. However, technology use comes with associated challenges that need to be addressed.
The use of diabetes technology in older adults is discussed in the following sections; under the umbrella term ‘diabetes technology’ we have included connected insulin pens, CGM, insulin pumps and automated insulin delivery (AID) systems.
Continuous glucose monitoring
Finger-prick blood glucose monitoring has long been a key component of the self-management of people living with diabetes. However, blood glucose monitoring provides a static view of the glucose profile and does not measure glucose excursions or undetected hypoglycaemia. Attenuating glucose variability and the risk of hypoglycaemia are major goals of diabetes management in older people. CGM, both real-time and ‘flash’ (the latter requiring manual swiping and now relatively obsolete), provides a dynamic view of glucose patterns, which is an advantage in older people at increased risk of hypoglycaemia. Many devices can also predict low and high glucose levels and give predictive warning alerts.
Most CGM devices have a ‘share’ feature that allows healthcare professionals, relatives and caregivers to review data remotely. Remote monitoring by healthcare and/or family members is a unique advantage of CGM in older people with diabetes and may be of particular value for those individuals living alone and for whom extra assistance is required. Diabetes technology also has the potential for seamless integration with other wearable devices aimed at tracking vital parameters. For example, the Dexcom and Freestyle Libre CGM systems allow users to share their glucose readings and alarms with up to 10 or 20 people, respectively. However, it is important to highlight that, although this feature can be valuable, some older adults may prefer not to share detailed insights, even with close family members such as spouses; this preference may vary depending on their level of comfort and degree of disability. Therefore, the decision to use the ‘share’ feature should be personalised according to the specific needs and preferences of each individual. However, there is evidence to suggest that older adults do not mind using the share feature with their caregivers [34].
Figure 1 illustrates some of the potential key benefits of CGM in older people with diabetes, and the text box ‘Case vignette: improved glucose levels and quality of life after escalation of diabetes technology’ provides an example of an individual who showed a profound improvement in quality of life with hypoglycaemia reduction after commencement of CGM as part of a clinical trial [35]. CGM has been shown to improve TIR and reduce time below range (TBR), and the risk of hypoglycaemia and hospitalisations [36]. CGM also has a positive impact on psychological outcomes, patient satisfaction and quality of life [36]. The Endocrine Society and the American Association of Clinical Endocrinology (AACE) recommend the use of CGM for people aged ≥65 years on insulin, even if they have physical and cognitive limitations [37, 38]. Consistent with these recommendations, the use of CGM in older people with type 1 and type 2 diabetes is gradually growing, as reported in a recent study from Germany using data from the Diabetes Prospective Follow-up Registry [39]. The benefits of technology shown in Fig. 1 also apply to pump therapy and include mitigation of glucose variability and reduction in hypoglycaemia risk. Clearly, there are many overlapping benefits between CGM and pump therapy in individuals with diabetes.
To date, the most robust evidence on the benefits of CGM for older adults derives from a few retrospective, qualitative and survey studies and RCTs, including a subanalysis of the DIAMOND study (Table 2). The DIAMOND study was a large RCT involving people with type 1 diabetes (aged 26–79 years) treated with insulin multiple daily injections that compared CGM with blood glucose monitoring [40]. This trial found that CGM was associated with greater reduction in HbA1c than blood glucose monitoring [40]. The seven studies included in Table 2 [41,42,43,44,45,46,47] found benefits of CGM in older people with diabetes, including reductions in HbA1c, less time above range, fewer episodes of hypoglycaemia or diabetic ketoacidosis, high levels of satisfaction, less TBR and more TIR.
CGM therefore has demonstrated benefits in terms of glycaemic outcomes, but there is still concern about its feasibility of use, as some technical aspects of CGM devices may impact older people’s confidence in their ability to manage them. Only one small study has demonstrated that the use of CGM is associated with high participant satisfaction and device acceptability and no additional distress [48].
CGM metric targets
In a consensus published in 2019, Battelino et al provide CGM targets for all older adults as well as people at high risk of severe hypoglycaemia due to duration of diabetes, duration of insulin treatment and impaired awareness of hypoglycaemia [49]. For this ‘high-risk’ group, the authors recommend a less stringent TIR (3.9–10.0 mmol/l glucose) target of >50% (vs >70% in general recommendations) and a TBR (<3.9 mmol/l glucose) target of <1% (vs <4% in general recommendations) [49], irrespective of frailty and functional status. Consensus CGM metric targets for older people with diabetes that take into consideration important factors such as comorbidities, health status and presence and severity of frailty are also needed. Trawley et al compared CGM data from older adults with type 1 diabetes collected during the run-in phase of the ORACL trial with the consensus-recommended CGM targets for all older adults with diabetes [50]. The authors highlighted that the recommended uniform TIR of >50% for all older adults (equating to an HbA1c of 67 mmol/mol [8.3%]) is inappropriately low for non-frail older adults using real-time CGM technology [50]. CGM targets should be revisited and personalised based on clinical aspects such as frailty, functional status and comorbidities, as well as the use or non-use of CGM or AID systems [50].
Bluetooth-enabled pens
In older people with diabetes, insulin dose errors, including missed insulin or double doses, are common and may account for suboptimal glycaemic management or unexplained glucose variability [51]. Advising insulin dose changes based on an incorrect assumption that an individual is following the prescribed insulin treatment can potentially lead to overtreatment and hypoglycaemia.
Bluetooth-enabled insulin pens, also known as smart pens, have been introduced to record insulin doses and time of administration. These pens can be extremely useful for older people who have mild memory impairment but who are otherwise capable of self-managing their diabetes (e.g. for reducing risk of hypoglycaemia and improving insulin treatment adherence). The concomitant use of smart pens and CGM has the potential to improve adherence to intended insulin dosing, detect accidental incorrect dosing and reduce the risk of problematic hypoglycaemia [52]. A downside of these pens is the need to replace the insulin cartridge, which may be a complex task for individuals with impaired dexterity without caregiver assistance.
Available smart pens can record and store data about insulin doses and injection timing and produce downloadable reports [53]. Through a ‘share’ function, caregivers and relatives can monitor treatment adherence. Smart pens also represent an excellent option for care home residents who are able to self-manage their diabetes under supervision. However, despite the proven benefits of smart pens in terms of TIR improvement and reduction in hypoglycaemia frequency, they have not yet been fully implemented in clinical practice [52].
Insulin pumps and AID systems
Insulin pump therapy can be a viable option for selected older adults who meet the clinical criteria. Indications for insulin pump therapy for older adults are the same as those for younger adults [54]. Although there is a large body of evidence demonstrating the efficacy of insulin pump therapy among younger adults with type 1 diabetes [54], evidence among older people is limited [55, 56]. A small number of studies and retrospective analyses have shown that insulin pump therapy is safe and effective in improving glycaemic management and reducing the risk of hypoglycaemia among adults with type 1 diabetes aged >60 years, but there are very minimal data from older groups and from individuals with medical complexity and physical and cognitive impairments. Clinicians must be mindful of comorbidities, and their treatments, which can contribute to type 1 diabetes management complexity, such as emergency management when insulin pump delivery interruption occurs [57].
Insulin pump therapy for older people is associated with benefits beyond glycaemic management and hypoglycaemia and has a positive impact on daily life (Table 3) [58,59,60,61,62,63]. Insulin pump therapy can also reduce the risk of hypoglycaemia and hospitalisation in both younger and older people, as demonstrated by a retrospective study in a Polish population [64].
The body of evidence on the use and benefits of diabetes technology is even more limited for AID systems (Table 3). Currently available AID systems, also referred to as hybrid closed-loop therapy, include an insulin pump and linked CGM device. The CGM measures interstitial glucose levels and an algorithm housed in the pump or in a mobile app adjusts the amount of insulin delivered according to the glucose levels. These current AID systems are considered to be ‘hybrid’ systems, as some information from the user (e.g. meal carbohydrate content) is still required to be entered manually.
The limited literature on the advantages of AID in older people suggests the need for further work. In a small study including 18 older adults with type 1 diabetes (mean ± SD age 74.1 ± 7.1 years) conducted by Pintaudi et al [58], the use of AID resulted in improvements in HbA1c at 1 year (mean ± SD 60 ± 11 mmol/mol [7.6% ± 3.1%] at baseline vs 53.2 ± 6.0 mmol/mol [7.0% ± 2.7%] at 1 year, p=0.01; mean difference 7 ± 10 mmol/mol [2.8% ± 3.1%]) and TIR at 48 weeks (p<0.0001) compared with baseline.
Two key randomised AID trials including individuals with type 1 diabetes aged >60 years have been recently published. The ORACL trial, a two-centre Australian study including 30 individuals with type 1 diabetes aged >60 years, compared a first-generation AID system (MiniMed 670G) with SAP therapy [59]. Compared with SAP therapy, using an AID system resulted in reduction in time spent in hypoglycaemia (<3.9 mmol/l) by a median of 0.5 percentage points (95% CI 0.3, 1.1; p=0.0005) [59]. There was a threefold reduction in nocturnal hypoglycaemia with AID and this effect was still detectable during actigraphy-measured sleep periods [65]. It is worth highlighting that in the trial only 20% of participants had mild cognitive impairment (none had moderate or severe cognitive impairment) and one-third had impaired awareness of hypoglycaemia. Only 20% were pre-frail and none was frail [59].
In a similar multinational, randomised, open-label crossover study conducted by Boughton et al [62], 37 people with type 1 diabetes aged ≥60 years (median [IQR] age 68 [63–70] years) were randomised to either an AID device (CamAPS FX) or SAP therapy for a period of 16 weeks. AID improved TIR by 8.6% through a reduction in time spent with glucose levels >16.7 mmol/l. There were no differences in time spent in hypoglycaemia (<3.9 mmol/l) between the two treatments [62]. Possible limitations of this trial were enrolling participants who were not necessarily representative of the heterogeneity of older people with type 1 diabetes and not screening for impairments in dexterity, vision, hearing or cognition. A trial subanalysis explored patient-reported outcomes [66]. Findings included significant improvements in diabetes distress overall (and with improvements in the powerlessness and physician distress subscales), in addition to improvement in trust in glucose monitoring [66].
A few additional small studies and RCTs have also shown benefits of insulin pump therapy in older people with type 2 diabetes [67, 68].
In young adults with type 1 diabetes the use of AID is associated with quality of life benefits, including a reduction in diabetes-related psychological burden and an improvement in sleep [69]. This would be an important advantage in older people as they tend to have disrupted sleep because of hyper- or hypoglycaemia and fear of hypoglycaemia. However, to date, the findings on the effects of AID on sleep quality have been disappointing. In the ORACL trial, sleep quality recorded daily was worse in those participants using the first-generation AID system (p=0.006) [65]. Similarly, in a post hoc analysis of the RCT conducted by Boughton et al [62], the use of the CamAPS FX device did not produce any improvement in sleep traits [63]. Lack of effect of an AID (vs SAP) on sleep parameters was also reported by Bisio et al in a small pilot trial [70].
Current-generation AID systems, with CGM no longer requiring calibration and algorithms with greater automation than in earlier systems, can now be used effectively in clinical care, even for older individuals with extensive comorbidities and suboptimal system interactions, such as missing meal announcements. However, to date, AID clinical trials have largely excluded such individuals.
Challenges related to the use of technology in older people
The use of technology holds promise to improve multiple outcomes in older people with diabetes, but its implementation is accompanied by many barriers that need to be overcome [71]. Figure 2 lists the key barriers to the use of technology in older people with diabetes.
Ageing is commonly associated with cognitive and physical decline and dexterity and visual impairments that interfere with diabetes self-care and do not allow the effective and safe use of technology devices unless the person with diabetes is supported by a relative or caregiver [71]. In a retrospective analysis by Toschi et al demonstrating the benefits of AID in older adults in terms of TIR and TBR, physical issues (dexterity and visual problems) and cognitive challenges were barriers to use for a few participants [60].
The text box ‘Case vignette: comorbidities and cognitive decline limiting the use of diabetes therapeutic technology’ provides an example where an individual’s comorbidities, cognitive decline and social situation were no longer conducive to the safe use of diabetes technology.
Personal preference and living circumstances are also important considerations. Some older individuals with diabetes are more inclined than others to use technology, and the level of available support, such as from a carer or family member, and/or proximity to specialised/tertiary centres where medical staff have expertise in the field of technology are relevant factors. Frail, non-independent individuals may need to live in care homes, where staff are less likely to possess the necessary skills to manage CGM devices and pumps. All of these factors can potentially result in age-related inequities.
Structural discrimination may also have a negative impact on access to technology [71]. Some groups of older people from ethnic minorities or with low incomes, limited education and low levels of health literacy may be socially marginalised and face barriers to internet and broadband access. Tackling these structural inequities necessitates reforms in both physical and social environments to promote equality across populations [71].
Among older adults, there can also be substantial variation in technology and digital literacy [7]. Technology literacy is defined as the ability to use technology devices safely and can be potentially enhanced by targeted education [7]. Digital literacy is defined as the ability to locate and consume, create and communicate digital content [7]. Older individuals may also have variable e-health literacy, a characteristic bridging health and technology [7]. As explained by Norman and Skinner, e-health literacy is the ‘ability to seek, find, understand, and appraise health information from electronic sources and apply the knowledge gained to addressing and solving a health problem’ [72].
CGM devices provide a large amount of data requiring interpretation and numeracy skills. Regardless of the level of literacy, data can be overwhelming for an older person with cognitive impairment and can trigger anxiety leading to rushed actions, insulin dosing errors and consequent hypoglycaemia.
Some procedures involved in the use of technology may represent complex tasks for older people. As a result of these difficulties, for instance, the infusion set may be left in place for longer than recommended, or the infusion set items may be reused or the pump discontinued. In addition, there is concern that older people may not be able to deal with issues related to pump function or, in the worst-case scenario, with pump failure, as problem-solving skills are known to decline with ageing.
There also challenges related to time constraints within health organisations. Because of cognitive impairment and medical complexity, the review of an older person and training of a family member or caregiver on the use of technology may require lengthy consultations and frequent follow-up. Another aspect to consider is the training of healthcare professionals on the use of technology. Older people with diabetes, particularly those who are frail, are often under the care of community diabetes specialist services. In this setting, clinicians are not always proficient in using CGM and other technology devices. Furthermore, diabetes specialists may not be familiar with tools for assessing cognition, mood, physical function and frailty and this raises the question whether older people with diabetes should be managed within dedicated multidisciplinary clinics.
Because of these barriers to the use of technology by older people, despite the advantages of CGM devices and pumps, most healthcare professionals prefer to continue with multiple daily injections. The lack of guidance on how to support older people with declining self-care skills in the use of technology may further amplify this attitude.
Assessment of older people for use of diabetes technology
Diabetes self-management requires lifelong commitment to numerous highly complex tasks including glucose monitoring, insulin dose adjustments and administration, hypoglycaemia management, self-coordination and planning. All of these tasks, requiring problem-solving and cognitive skills, are essential to achieve successful health-related outcomes.
Ageing and diabetes both increase the risk of comorbidities, including cognitive impairment, depression, visual acuity reduction and impaired dexterity, which can potentially cause physical and mental decline and frailty and interfere with individuals’ self-care abilities [73]. A list of domains to be assessed in older people before and while using technology is provided in Fig. 1, and some key assessments [74,75,76] are described in Table 4, which also includes key outcome measures relating to the potential positive impact of technology in older people with diabetes.
Areas for future research and improvement
The emerging body of evidence regarding the efficacy and safety of diabetes technology use among the older population is largely limited to individuals without comorbidities who are cognitively intact and living in their own homes. We have identified the following areas for future research and further development (Fig. 3):
-
real-world observational studies and RCTs exploring the impact of CGM, pumps and AID on outcomes of interest to the ageing population (geriatric syndromes and life expectancy) and including individuals with a broad spectrum of frailty
-
identification of strategies for implementing diabetes technology alongside other technology (blood pressure monitoring, cardiac monitoring, oxygen monitoring) to support frail older people at home and in long-term facilities, to avoid hospitalisations and readmissions
-
research aimed at adapting diabetes technology to older people with diabetes, frailty and disability, for both people who manage independently and those needing assistance
-
research on the efficacy, safety and cost-effectiveness of the use of diabetes technology in all living settings including care homes
-
guidelines on the use of diabetes technology in older people with diabetes and cognitive and physical impairments
-
recommendations on CGM-based metrics for older people, stratified by health status, comorbidities, frailty and life expectancy
-
training on the use of technology for care homes staff looking after residents with diabetes
-
interventions to improve e-literacy among older people with diabetes
-
development of pumps and AID systems that can be operated remotely either by a caregiver or a relative.
We must also remain cognisant that most glucose sensors, and all current pumps, are worn externally; therefore, the available skin ‘real estate’ is a major factor in decisions around the use of technology. Ageing skin has high rates of dermatological conditions and may have less resilience to the adhesives/piercing required, which may limit its usage for many individuals. If people are on anti-platelet agents or anti-coagulants, bruising can be a major issue at insertion sites [77, 78]. Future research could focus on developing alternative adhesive materials or insertion techniques to address these challenges and improve the acceptance and usability of technology.
Conclusions
Given the improvement in life expectancy of adults with diabetes, clinicians will soon face the challenge of providing care to more older people with long-duration type 1 diabetes or type 2 diabetes treated with insulin and co-existing long-term conditions. The heterogeneity characterising this group of individuals is a key factor in the pronounced glucose variability observed, as well as the increased risk of hypoglycaemia, effects of medical comorbidities and their ability to use diabetes technology. Individually tailored adoption of CGM devices, pumps and AID systems appears to be the most sensible strategy to improve TIR and reduce the risk of hypoglycaemia and hyperglycaemia in this group, which, in turn, could improve physical and cognitive function and quality of life; however, further well-designed research is needed to confirm these benefits.
While technology holds promise for enhancing the lives of older adults, it is important to be mindful of its limitations and potential pitfalls. Certain characteristics, such as advanced age, limited digital literacy, cognitive decline and physical impairments, should be considered when implementing technology solutions for older individuals. Additionally, factors such as privacy concerns, reluctance to adopt new technologies and the need for personalised support and training should also be considered when designing technology interventions for this population. By acknowledging these challenges and incorporating appropriate caveats, technology developers and healthcare professionals can ensure that technology is effectively used to support older adults while minimising potential risks and drawbacks.
Implementation of technology should be considered after a careful and comprehensive assessment of each individual, looking at multiple domains including social context and living setting. Training and education should be provided to family members and caregivers of frail older people with disability to support their use of diabetes technology.
Abbreviations
- AID:
-
Automated insulin delivery
- CGM:
-
Continuous glucose monitoring
- SAP:
-
Sensor-augmented pump
- TBR:
-
Time below range
- TIR:
-
Time in range
References
Sun H, Saeedi P, Karuranga S et al (2022) IDF Diabetes Atlas: Global, regional and country-level diabetes prevalence estimates for 2021 and projections for 2045. Diabetes Res Clin Pract 183:109119. https://doi.org/10.1016/j.diabres.2021.109119
Ong KL, Stafford LK, McLaughlin SA et al (2023) Global, regional, and national burden of diabetes from 1990 to 2021, with projections of prevalence to 2050: a systematic analysis for the Global Burden of Disease Study 2021. The Lancet 402(10397):203–234. https://doi.org/10.1016/S0140-6736(23)01301-6
Barron E, Bakhai C, Kar P et al (2020) Associations of type 1 and type 2 diabetes with COVID-19-related mortality in England: a whole-population study. Lancet Diabetes Endocrinol 8(10):813–822. https://doi.org/10.1016/S2213-8587(20)30272-2
Miller RG, Secrest AM, Sharma RK, Songer TJ, Orchard TJ (2012) Improvements in the life expectancy of type 1 diabetes: the Pittsburgh Epidemiology of Diabetes Complications study cohort. Diabetes 61(11):2987–2992. https://doi.org/10.2337/db11-1625
Huo L, Harding JL, Peeters A, Shaw JE, Magliano DJ (2016) Life expectancy of type 1 diabetic patients during 1997–2010: a national Australian registry-based cohort study. Diabetologia 59:1177–1185. https://doi.org/10.1007/s00125-015-3857-4
Abdelhafiz AH, Rodriguez-Manas L, Morley JE, Sinclair AJ (2015) Hypoglycemia in older people - a less well recognized risk factor for frailty. Aging Dis 6(2):156–167. https://doi.org/10.14336/AD.2014.0330
Huang ES, Sinclair A, Conlin PR et al (2023) The growing role of technology in the care of older adults with diabetes. Diabetes Care 46(8):1455–1463. https://doi.org/10.2337/dci23-0021
Bellary S, Kyrou I, Brown JE, Bailey CJ (2021) Type 2 diabetes mellitus in older adults: clinical considerations and management. Nat Rev Endocrinol 17(9):534–548. https://doi.org/10.1038/s41574-021-00512-2
ElSayed NA, Aleppo G, Aroda VR et al (2023) 13. Older adults: standards of care in diabetes-2023. Diabetes Care 46(Suppl 1):S216–S229. https://doi.org/10.2337/dc23-S013
Munshi MN, Segal AR, Suhl E et al (2011) Frequent hypoglycemia among elderly patients with poor glycemic control. Arch Intern Med 171(4):362–364. https://doi.org/10.1001/archinternmed.2010.539
Meneilly GS, Cheung E, Tuokko H (1994) Altered responses to hypoglycemia of healthy elderly people. J Clin Endocrinol Metab 78(6):1341–1348. https://doi.org/10.1210/jcem.78.6.8200936
Yaffe K, Falvey CM, Hamilton N et al (2013) Association between hypoglycemia and dementia in a biracial cohort of older adults with diabetes mellitus. JAMA Intern Med 173(14):1300–1306. https://doi.org/10.1001/jamainternmed.2013.6176
Munshi M, Slyne C, Adam A et al (2022) Impact of diabetes duration on functional and clinical status in older adults with type 1 diabetes. Diabetes Care 45(3):754–757. https://doi.org/10.2337/dc21-2000
Munshi MN, Segal AR, Slyne C, Samur AA, Brooks KM, Horton ES (2015) Shortfalls of the use of HbA1C-derived eAG in older adults with diabetes. Diabetes Res Clin Pract 110(1):60–65. https://doi.org/10.1016/j.diabres.2015.07.012
Dubowitz N, Xue W, Long Q et al (2014) Aging is associated with increased HbA1c levels, independently of glucose levels and insulin resistance, and also with decreased HbA1c diagnostic specificity. Diabet Med 31(8):927–935. https://doi.org/10.1111/dme.12459
Monnier L, Colette C, Owens DR (2008) Glycemic variability: the third component of the dysglycemia in diabetes. Is it important? How to measure it? J Diabetes Sci Technol 2(6):1094–1100. https://doi.org/10.1177/193229680800200618
Nusca A, Tuccinardi D, Albano M et al (2018) Glycemic variability in the development of cardiovascular complications in diabetes. Diabetes Metab Res Rev 34(8):e3047. https://doi.org/10.1002/dmrr.3047
Echouffo-Tcheugui JB, Zhao S, Brock G, Matsouaka RA, Kline D, Joseph JJ (2019) Visit-to-visit glycemic variability and risks of cardiovascular events and all-cause mortality: the ALLHAT study. Diabetes Care 42(3):486–493. https://doi.org/10.2337/dc18-1430
Torimoto K, Okada Y, Mori H, Tanaka Y (2013) Relationship between fluctuations in glucose levels measured by continuous glucose monitoring and vascular endothelial dysfunction in type 2 diabetes mellitus. Cardiovasc Diabetol 12:1. https://doi.org/10.1186/1475-2840-12-1
Chang CM, Hsieh CJ, Huang JC, Huang IC (2012) Acute and chronic fluctuations in blood glucose levels can increase oxidative stress in type 2 diabetes mellitus. Acta Diabetol 49(Suppl 1):S171-177. https://doi.org/10.1007/s00592-012-0398-x
Ji SH, Dong C, Chen R et al (2022) Effects of variability in glycemic indices on longevity in chinese centenarians. Front Nutr 9:955101. https://doi.org/10.3389/fnut.2022.955101
Klimontov VV, Myakina NE (2017) Glucose variability indices predict the episodes of nocturnal hypoglycemia in elderly type 2 diabetic patients treated with insulin. Diabetes Metab Syndr 11(2):119–124. https://doi.org/10.1016/j.dsx.2016.08.023
Rodbard D (2018) Glucose variability: a review of clinical applications and research developments. Diabetes Technol Ther 20(S2):S25–S215. https://doi.org/10.1089/dia.2018.0092
Toschi E, Slyne C, Sifre K et al (2020) The relationship between CGM-derived metrics, A1C, and risk of hypoglycemia in older adults with type 1 diabetes. Diabetes Care 43(10):2349–2354. https://doi.org/10.2337/dc20-0016
Chi H, Song M, Zhang J, Zhou J, Liu D (2023) Relationship between acute glucose variability and cognitive decline in type 2 diabetes: a systematic review and meta-analysis. PLoS One 18(9):e0289782. https://doi.org/10.1371/journal.pone.0289782
Li TC, Yang CP, Tseng ST et al (2017) Visit-to-visit variations in fasting plasma glucose and HbA(1c) associated with an increased risk of Alzheimer disease: Taiwan diabetes study. Diabetes Care 40(9):1210–1217. https://doi.org/10.2337/dc16-2238
Chung SM, Lee YH, Kim CO et al (2021) Daytime glycemic variability and frailty in older patients with diabetes: a pilot study using continuous glucose monitoring. J Korean Med Sci 36(27):e190. https://doi.org/10.3346/jkms.2021.36.e190
Fung E, Lui LT, Huang L et al (2021) Characterising frailty, metrics of continuous glucose monitoring, and mortality hazards in older adults with type 2 diabetes on insulin therapy (HARE): a prospective, observational cohort study. Lancet Healthy Longev 2(11):e724–e735. https://doi.org/10.1016/S2666-7568(21)00251-8
Idrees T, Zabala ZE, Moreno EM et al (2023) The effects of aging and frailty on inpatient glycemic control by continuous glucose monitoring in patients with type 2 diabetes. Diabetes Res Clin Pract 198:110603. https://doi.org/10.1016/j.diabres.2023
Forbes A, Murrells T, Mulnier H, Sinclair AJ (2018) Mean HbA(1c), HbA(1c) variability, and mortality in people with diabetes aged 70 years and older: a retrospective cohort study. Lancet Diabetes Endocrinol 6(6):476–486. https://doi.org/10.1016/S2213-8587(18)30048-2
Ma GC, Zou LL, Dai W, Wang ZZ, Cao YH (2023) The association between glucose fluctuation with sarcopenia in elderly patients with type 2 diabetes mellitus. Eur Rev Med Pharmacol Sci 27(5):1912–1920. https://doi.org/10.26355/eurrev_202303_31557
Zhang J, Yang J, Liu L et al (2021) Significant abnormal glycemic variability increased the risk for arrhythmias in elderly type 2 diabetic patients. BMC Endocr Disord 21(1):83. https://doi.org/10.1186/s12902-021-00753-2
Cox DJ, McCall A, Kovatchev B, Sarwat S, Ilag LL, Tan MH (2007) Effects of blood glucose rate of changes on perceived mood and cognitive symptoms in insulin-treated type 2 diabetes. Diabetes Care 30(8):2001–2002. https://doi.org/10.2337/dc06-2480
Allen NA, Litchman ML, Chamberlain J, Grigorian EG, Iacob E, Berg CA (2022) Continuous glucose monitoring data sharing in older adults with type 1 diabetes: pilot intervention study. JMIR Diabetes 7(1):e35687. https://doi.org/10.2196/35687
Grills CA, McAuley S (2022) Escalation of diabetes therapeutic technology to improve glycaemia and quality of life: a case from the ORACL trial. Aust Diabetes Educ 25(1)
Munshi MN (2023) Continuous glucose monitoring use in older adults for optimal diabetes management. Diabetes Technol Ther 25(S3):S56–S64. https://doi.org/10.1089/dia.2023.0111
Grunberger G, Sherr J, Allende M et al (2021) American association of clinical endocrinology clinical practice guideline: the use of advanced technology in the management of persons with diabetes mellitus. Endocr Pract 27(6):505–537. https://doi.org/10.1016/j.eprac.2021.04.008
LeRoith D, Biessels GJ, Braithwaite SS et al (2019) Treatment of diabetes in older adults: an endocrine society* clinical practice guideline. J Clin Endocrinol Metab 104(5):1520–1574. https://doi.org/10.1210/jc.2019-00198
Grammes J, Schmid S, Bozkurt L et al (2024) Continuous glucose monitoring in older adults with diabetes: data from the diabetes prospective follow-up (DPV) registry. Diabet Med 41(3):e15261. https://doi.org/10.1111/dme.15261
Beck RW, Riddlesworth T, Ruedy K et al (2017) Effect of continuous glucose monitoring on glycemic control in adults with type 1 diabetes using insulin injections: the DIAMOND randomized clinical trial. JAMA 317(4):371–378. https://doi.org/10.1001/jama.2016.19975
Ruedy KJ, Parkin CG, Riddlesworth TD, Graham C, Group DS (2017) Continuous glucose monitoring in older adults with type 1 and type 2 diabetes using multiple daily injections of insulin: results from the DIAMOND trial. J Diabetes Sci Technol 11(6):1138–1146. https://doi.org/10.1177/1932296817704445
Pratley RE, Kanapka LG, Rickels MR et al (2020) Effect of continuous glucose monitoring on hypoglycemia in older adults with type 1 diabetes: a randomized clinical trial. JAMA 323(23):2397–2406. https://doi.org/10.1001/jama.2020.6928
Bao S, Bailey R, Calhoun P, Beck RW (2022) Effectiveness of continuous glucose monitoring in older adults with type 2 diabetes treated with basal insulin. Diabetes Technol Ther 24(5):299–306. https://doi.org/10.1089/dia.2021.0494
Guerci B, Levrat-Guillen F, Vicaut E et al (2023) Reduced acute diabetes events after FreeStyle Libre system initiation in people 65 years or older with type 2 diabetes on intensive insulin therapy in France. Diabetes Technol Ther 25(6):384–394. https://doi.org/10.1089/dia.2023.0034
Reaven PD, Newell M, Rivas S, Zhou X, Norman GJ, Zhou JJ (2023) Initiation of continuous glucose monitoring is linked to improved glycemic control and fewer clinical events in type 1 and type 2 diabetes in the Veterans health administration. Diabetes Care 46(4):854–863. https://doi.org/10.2337/dc22-2189
Polonsky WH, Peters AL, Hessler D (2016) The impact of real-time continuous glucose monitoring in patients 65 years and older. J Diabetes Sci Technol 10(4):892–897. https://doi.org/10.1177/1932296816643542
Litchman ML, Allen NA (2017) Real-time continuous glucose monitoring facilitates feelings of safety in older adults with type 1 diabetes: a qualitative study. J Diabetes Sci Technol 11(5):988–995. https://doi.org/10.1177/1932296817702657
Larsen AB, Hermann M, Graue M (2021) Continuous glucose monitoring in older people with diabetes receiving home care-a feasibility study. Pilot Feasibility Stud 7(1):12. https://doi.org/10.1186/s40814-020-00754-3
Battelino T, Danne T, Bergenstal RM et al (2019) Clinical targets for continuous glucose monitoring data interpretation: recommendations from the international consensus on time in range. Diabetes Care 42(8):1593–1603. https://doi.org/10.2337/dci19-0028
Trawley S, Ward GM, Vogrin S et al (2022) Glucose profiles of older adults with type 1 diabetes using sensor-augmented pump therapy in Australia: pre-randomisation results from the ORACL study. Lancet Healthy Longev 3(12):e839–e848. https://doi.org/10.1016/S2666-7568(22)00266-5
Munshi MN, Slyne C, Greenberg JM et al (2019) Nonadherence to insulin therapy detected by bluetooth-enabled pen cap is associated with poor glycemic control. Diabetes Care 42(6):1129–1131. https://doi.org/10.2337/dc18-1631
Adolfsson P, Hartvig NV, Kaas A, Moller JB, Hellman J (2020) Increased time in range and fewer missed bolus injections after introduction of a smart connected insulin pen. Diabetes Technol Ther 22(10):709–718. https://doi.org/10.1089/dia.2019.0411
Sangave NA, Aungst TD, Patel DK (2019) Smart connected insulin pens, caps, and attachments: a review of the future of diabetes technology. Diabetes Spectr 32(4):378–384. https://doi.org/10.2337/ds18-0069
ElSayed NA, Aleppo G, Aroda VR et al (2023) 7. Diabetes technology: standards of care in diabetes-2023. Diabetes Care 46(Suppl 1):S111–S127. https://doi.org/10.2337/dc23-S007
Briganti EM, Summers JC, Fitzgerald ZA, Lambers LNJ, Cohen ND (2018) Continuous subcutaneous insulin infusion can be used effectively and safely in older patients with type 1 diabetes: long-term follow-up. Diabetes Technol Ther 20(11):783–786. https://doi.org/10.1089/dia.2018.0215
Boulet G, Halpern EM, Lovblom LE et al (2016) Prevalence of insulin pump therapy and its association with measures of glycemic control: results from the canadian study of longevity in type 1 diabetes. Diabetes Technol Ther 18(5):298–307. https://doi.org/10.1089/dia.2015.0216
Chakrabarti A, MacIsaac RJ, McAuley SA (2022) Insulin pump troubleshooting: a case vignette and systematic approach. Med J Aust 216(11):595–596. https://doi.org/10.5694/mja2.51559
Pintaudi B, Gironi I, Meneghini E et al (2023) Advanced hybrid closed loop system use in elderly with type 1 diabetes: effectiveness and safety in a prospective, observational, 1-year follow-up real-world study. Diabetes Obes Metab 25(7):2034–2037. https://doi.org/10.1111/dom.15055
McAuley SA, Trawley S, Vogrin S et al (2022) Closed-loop insulin delivery versus sensor-augmented pump therapy in older adults with type 1 diabetes (ORACL): a randomized, crossover trial. Diabetes Care 45(2):381–390. https://doi.org/10.2337/dc21-1667
Toschi E, Atakov-Castillo A, Slyne C, Munshi M (2022) Closed-loop insulin therapy in older adults with type 1 diabetes: real-world data. Diabetes Technol Ther 24(2):140–142. https://doi.org/10.1089/dia.2021.0311
Chakrabarti A, Mohammad Alipoor A, Sandra Segaran TR et al (2022) Exercise habits and glucose management among older adults with type 1 diabetes using insulin pumps. Acta Diabetol 59(6):865–868. https://doi.org/10.1007/s00592-022-01858-3
Boughton CK, Hartnell S, Thabit H et al (2022) Hybrid closed-loop glucose control compared with sensor augmented pump therapy in older adults with type 1 diabetes: an open-label multicentre, multinational, randomised, crossover study. Lancet Healthy Longev 3(3):e135–e142. https://doi.org/10.1016/S2666-7568(22)00005-8
Thabit H, Boughton C, Mubita W et al (2023) Impact of the CamAPS FX hybrid closed-loop insulin delivery system on sleep traits in older adults with type 1 diabetes. Diabetes Obes Metab 25(3):889–893. https://doi.org/10.1111/dom.14914
Matejko B, Cyganek K, Katra B et al (2011) Insulin pump therapy is equally effective and safe in elderly and young type 1 diabetes patients. Rev Diabet Stud 8(2):254–258. https://doi.org/10.1900/RDS.2011.8.254
Chakrabarti A, Trawley S, Kubilay E et al (2022) Closed-loop insulin delivery effects on glycemia during sleep and sleep quality in older adults with type 1 diabetes: results from the ORACL trial. Diabetes Technol Ther 24(9):666–671. https://doi.org/10.1089/dia.2022.0110
Schneider-Utaka AK, Hanes S, Boughton CK et al (2023) Patient-reported outcomes for older adults on CamAPS FX closed loop system. Diabet Med 40(9):e15126. https://doi.org/10.1111/dme.15126
Johnson SL, McEwen LN, Newton CA et al (2011) The impact of continuous subcutaneous insulin infusion and multiple daily injections of insulin on glucose variability in older adults with type 2 diabetes. J Diabetes Complications 25(4):211–215. https://doi.org/10.1016/j.jdiacomp.2010.09.005
Reznik Y, Cohen O, Aronson R et al (2014) Insulin pump treatment compared with multiple daily injections for treatment of type 2 diabetes (OpT2mise): a randomised open-label controlled trial. Lancet 384(9950):1265–1272. https://doi.org/10.1016/S0140-6736(14)61037-0
Kubilay E, Trawley S, Ward GM et al (2023) Lived experience of older adults with type 1 diabetes using closed-loop automated insulin delivery in a randomised trial. Diabet Med 40(4):e15020. https://doi.org/10.1111/dme.15020
Bisio A, Gonder-Frederick L, McFadden R et al (2022) The impact of a recently approved automated insulin delivery system on glycemic, sleep, and psychosocial outcomes in older adults with type 1 diabetes: a pilot study. J Diabetes Sci Technol 16(3):663–669. https://doi.org/10.1177/1932296820986879
Toschi E, Munshi MN (2020) Benefits and challenges of diabetes technology use in older adults. Endocrinol Metab Clin North Am 49(1):57–67. https://doi.org/10.1016/j.ecl.2019.10.001
Norman CD, Skinner HA (2006) eHealth literacy: essential skills for consumer health in a networked world. J Med Internet Res 8(2):e9. https://doi.org/10.2196/jmir.8.2.e9
Munshi M (2008) Managing the “geriatric syndrome” in patients with type 2 diabetes. Consult Pharm 23(Suppl B):12–16. https://doi.org/10.4140/TCP.sB.2008.1
Sinclair AJ, Abdelhafiz A, Dunning T et al (2018) An international position statement on the management of frailty in diabetes mellitus: summary of recommendations 2017. J Frailty Aging 7(1):10–20. https://doi.org/10.14283/jfa.2017.39
Sinclair AJ, Gadsby R, Hillson R, Forbes A, Bayer AJ (2013) Brief report: use of the Mini-Cog as a screening tool for cognitive impairment in diabetes in primary care. Diabetes Res Clin Pract 100(1):e23-25. https://doi.org/10.1016/j.diabres.2013.01.001
Yesavage JAS (1986) J. I. 9/Geriatric Depression Scale (GDS): recent evidence and development of a shorter version. Clin Gerontol 5(1–2):165–173. https://doi.org/10.1300/J018v05n01_09
Seirafi H, Farsinejad K, Firooz A et al (2009) Biophysical characteristics of skin in diabetes: a controlled study. J Eur Acad Dermatol Venereol 23(2):146–149. https://doi.org/10.1111/j.1468-3083.2008.02950.x
Sinikumpu SP, Jokelainen J, Haarala AK, Keranen MH, Keinanen-Kiukaanniemi S, Huilaja L (2020) The high prevalence of skin diseases in adults aged 70 and older. J Am Geriatr Soc 68(11):2565–2571. https://doi.org/10.1111/jgs.16706
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Acknowledgements
We thank M. Scivier (person living with diabetes) and the Great British Diabetes Online Community (#GBdoc), for their input on the section entitled ‘Challenges related to the use of technology in older people’.
Funding
No funding was received for this work. Related work undertaken by SAM’s research group has been supported by funding from Breakthrough T1D (formerly JDRF; grants 5-ECR-2017-371-A-N and 3-SRA-2018-667-M-R) and the Diabetes Australia Research Program.
Authors’ relationships and activities
The authors declare that there are no relationships or activities that might bias, or be perceived to bias, their work.
Contribution statement
GM and AJS designed and drafted the review. SAM and ST revised it critically for important intellectual content. All authors approved the final manuscript to be published.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Below is the link to the electronic supplementary material.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Maltese, G., McAuley, S.A., Trawley, S. et al. Ageing well with diabetes: the role of technology. Diabetologia (2024). https://doi.org/10.1007/s00125-024-06240-2
Received:
Accepted:
Published:
DOI: https://doi.org/10.1007/s00125-024-06240-2