1 Introduction

Salty crackers and sweet biscuits made from shortcrust pastry are one of the most popular snacks all over the world being also the most important segment of the global confectionery market. On the other hand, nowadays most consumers pay attention to food quality and safety, and the presence of chemical contaminants in food—besides microbiological hazards—is one of the basic evaluation criteria of food safety.

The basic ingredients of shortcrust pastry are flour, fats and/or oils, sugars, eggs, salt, flavourings or spices, and optionally leavening agents such as sodium bicarbonate (Zalewski 2009). Chemical reactions during baking like the Maillard reaction, lipid oxidation and caramelisation (Van Der Fels-Klerx et al. 2014) are essential for final sensorial attributes of the pastry, however, these reactions also lead to the formation of harmful components such as chloropropanols. 3-monochloropropane-1,2-diol (3-MCPD) is the most abundant chloropropanol found in foodstuff and a potential human carcinogen. The provisional maximum tolerable daily intake in the European Union is 2 μg kg−1 body weight (Hamlet et al. 2003).

In general, 3-MCPD in food can derive through 3 different pathways: acid hydrolysis, heat processing, and via 3-MCPD esters. Thus, it occurs in a wide range of other food items (Baer et al. 2010). In cereal products with a low water content (<15 %) and shortcrust pastry, 3-MCPD forms out of lipids and sodium chloride (natural or added) during baking at temperatures above 160 °C (Chung et al. 2008). White flour, salt and water alone are also sufficient to generate 3-MCPD, while sugar does seem to have a strong influence on the production of 3-MCPD (Baer et al. 2010). However, its presence turned out to be one of the factors in promoting 3-MCPD formation. Other components of the pastry (e.g baking agents) do not contribute to 3-MCPD formation during baking (Breitling-Utzmann et al. 2005). 3-MCPD can also generate from 3-MCPD esters present in fats, oils, or margarine used in shortcrust pastry production. In this case, free 3-MCPD is released under lipase-catalysed hydrolysis during storage and processing (Teng and Wang 2014). The presence of 3-MCPD may be due to its migration from certain types of epichlorohydrin-based paper and cellulose packaging (Chung et al. 2008). Hence, 3-MCPD was found in dried savoury and sweet foods containing salt and fat, such as crisp bread, salty crackers, biscuits, doughnuts (Svejkovská et al. 2006). Although the overall levels of 3-MCPD in bakery products are relatively low, the high amount of product consumption indicates a significant dietary source of 3-MCPD (Wenzl et al. 2007).

3-MCPD is not very stable in foods, and its amount is a result of the mass balance between formation and decomposition (Baer et al. 2010). The stability of 3-MCPD is very sensitive to both pH and temperature changes and to the decrease of moisture and the drop of pH; as seen at high temperatures in cereal systems that inhibit the decay reaction. It has been shown that the storage of simple model dough for one week prior cooking produced twice the amount of 3-MCPD compared to the freshly prepared doughs (Baer et al. 2010). However, in another study (Hamlet et al. 2003), the concentration of 3-MCPD in spiked dough kept at 3 °C over 24 h remained unchanged. It is also presumed that 3-MCPD can be removed by both hydrolysis and photolysis methods. Nonetheless, these findings were conducted only in water, for which it has been shown that the UV/H2O2 process takes 3-MCPD to nearly complete conversion within minutes, whereas hydrolysis at reasonable temperatures takes several months (Nienow et al. 2009). This kind of research has not been performed in food yet.

There is little information on whether packaging material for storage is associated to heat-induced 3-MCPD levels in ready-to-eat food products like crackers or biscuits. Apart from data reported by Pace and Hartman (2010) and Mezouari et al. (2015), existing data still remain unclear and incomplete in the literature. While we cannot exclude that 3-MCPD levels in food change products like biscuits and crackers are widely consumed throughout the world, these questions needed to be addressed.

Therefore, the aim of this study was to evaluate the degradation of free 3-MCPD in sweet biscuits and salty crackers during storage from 1 to 5 months. The investigation on the impact of packaging materials on 3-MCPD levels during storage was also performed. Finally, we checked the possibility of degradation of 3-MCPD upon sunlight exposure.

2 Materials and methods

2.1 Chemicals and reagents

Hexane, acetone and acetonitrile, HPLC grade for liquid chromatography LiChrosolv® were purchased from Merck KGaA, Darmstadt, Germany. Sodium chloride was purchased from Chempur SA, Piekary Śląskie, Poland. PSA (primary secondary amine), C18 (octadecyl) SPE Bulk Sorbent derived from Agilent Technologies, Santa Clara, California, USA. 3-monochloropropane-1,2-diol (3-MCPD), 3-monochloropropane-1,2-diol-d5 (3-MCPD-d5) (surrogate standard, applied to calculate the recovery), 3-monobromochloropropane-1,2-diol (3-MBPD) (syringe standard, used to compensate the possible changes of extract volume and analyte signal during GC–MS analysis), and phenylboronic acid (PBA) (derivatisation agent) were obtained from Sigma-Aldrich, Saint Louis, Missouri, USA. A sodium chloride solution of 200 mg mL−1 (20 %) was prepared in deionised water. Intermediate and working standard solutions of chloropropanols at concentration 2 µg mL−1 were prepared in 20 % NaCl solution. PBA solution was prepared by dissolving 5 g PBA in 20 mL mixture of acetone and water (19:1, v/v).

2.2 Instrumentation

The Varian 4000 GC/MS (Agilent Technologies, Santa Clara, California, USA) system consisting of a 3800 GC with a CP-8410 auto-injector (Bruker, Billerica, Massachusetts, USA) and a 4000 Ion Trap MS detector was used to perform the analyses. The injector was a CP-1177 Split/Splitless Capillary Injector, with a temperature of 180 °C, and an injection volume of 1.0 µL. Each injection was performed in triplicate. Chromatographic separations were conducted using a DB-5MS column (30 m × 0.25 mm × 0.25 μm; Agilent Technologies, Santa Clara, California, USA). The GC oven was operated with the following temperature program: initial temperature 60 °C (1.0 min)—6 °C min−1—190 °C (1.0 min)—30 °C min−1—280 °C (6.0 min). The analyses were carried out with a solvent delay of 8.0 min. Helium 5.0 (Linde Group, Munich, Germany) was used as the GC carrier gas at a flow rate of 1.0 mL min−1. The ion trap mass spectrometer was operated in the internal ionisation mode, scan from m/z 45 to 500. The emission current of the ionisation filament was set at 10 µA. The trap and the transfer line temperatures were set on 180 and 230 °C, respectively. Analyses were conducted in the selected ion monitoring mode (SIM) based on using one quantitative ion of PBA derivatives (147 for 3-MCPD and 3-MBPD, 150 for 3-MCPD-d5), qualitative ions (196 for 3-MCPD, 201 for 3-MCPD-d5 and 241 for 3-MBPD) and retention times (17.07, 17.14 and 18.29 for 3-MCPD-d5, 3-MCPD and 3-MBPD, respectively). Acquisition and processing data were performed using Varian Start Workstation software (Agilent Technologies, Santa Clara, California, USA) and NIST 2.0 library (National Institute of Standards and Technology, Gaithersburg, Maryland, USA). MS1 Minishaker (IKA, Königswinter, Germany), MPW 350 R Centrifuge (MPW Med. Instruments, Warsaw, Poland) were employed during the sample preparation. Accublock™ (Labnet, Edison, NJ, USA) with nitrogen 5.0 (Linde Group, Munich, Germany) was used to evaporate the solvent and concentrate the extracts.

2.3 Experimental setup

The research material consisted of fresh shortcrust pastry cookies with sugar (sweet butter biscuits) and salty crackers. The cookie ingredients (declared by the producer) and components important for 3-MCPD formation (fat, salt, sugar and water) are summarized in Table 1. The selection of the products was designed to verify the influence of sugar and salt presence on the 3-MCPD levels in the investigated products. However, due to the fact that the levels of 3-MCPD in cereal products are usually too low to observe significant changes during storage period, the tested samples were additionally enriched with a mixture of 3-MCPD to 40 µg kg−1.

Table 1 Ingredients and content of investigated samples

Based on the fact that paper as well as various plastic polymers, including polyethylenes, are the most common packaging materials for biscuits and crackers (Robertson 2011), we used standard paper and polyethylene bags for our experiments, both intended for contact with food. Crackers and biscuits were homogenized and divided into 2 parts. First part of the samples was fortified with the mixture of 3-MCPD in a suitable amount of hexane. After thorough blending of the mixtures, hexane was left to evaporate, and then the mixtures were blended once again. The second part of the samples were blank samples. In each variant of storage (9 in total), 5 replicates were prepared.

The samples were packed in appropriate paper or polyethylene packaging bags and stored for a suitable period of time (1, 3, 5 months). Additionally, we applied sunlight exposure to some samples, while the rest were wrapped tightly in aluminum foil to store away from light (Fig. 1). All samples stored in paper bags were additionally put into polyethylene bags in order to avoid air contact. The storage experiment took place in an air-conditioned laboratory and the storage conditions were established according to polish standard PN-A-74859:1994 (PKN 2016); which is 18 ± 2 °C and 45 % relative air humidity. After various storage time periods, the 3-MCPD content was analyzed and compared to the initial 3-MCPD levels prior storage.

Fig. 1
figure 1

Storage experiment setup

2.4 Determination of 3-MCPD

The analytical procedure for the validation process used in this study was described previously involving i.e. method linearity, limit of detection and quantification, precision, accuracy and uncertainty (Sadowska-Rociek et al. 2016). Briefly, the correlation coefficient of the calibration curve (range 0.5–50 ng mL−1) was higher than 0.99, limit of detection (LOD) and limit of quantification (LOQ), estimated on the basis of the signal of the background noise were lower than 3.1 and 9.3 μg kg−1, respectively. Repeatability (RSDr) and reproducibility (RSDR), both expressed as a relative standard deviation, were lower than 5.6 and 7.7 %, respectively. The method accuracy was determined with the recovery using spiked samples, because neither certified reference materials nor proficiency test programs for free 3-MCPD analysis in shortbread were available. The results were equal to 95.6 % for biscuits and 107.8 % for crackers. The relative expanded uncertainty (rUc) expressed as a percent value (p = 0.05; k = 2) was estimated to be 12.3 % for biscuits and 13.1 % for crackers. All parameters were with in good agreement with the values established by Commission Regulation No 836/2011.

1 g of the sample was weighted into a 50 mL centrifuge tube, spiked with 3-MCPD-d5 solution to the level of 40 µg kg−1, mixed and left to stand for 15 min at room temperature prior to extraction. Then, 5 mL of water and 10 mL of acetonitrile was added and the mixture was shaken vigorously for 1 min. Next, 1 g of NaCl was added, the sample was shaken vigorously for 1 min., and centrifuged for 15 min at 9000 rpm. 8 mL of the supernatant was transferred into a 15 mL glass vial and the extracts were kept in a freezer (−20 °C) overnight to freeze out the fat. Thereafter the extract was immediately filtrated to remove precipitated co-extractives. 6 mL of filtrate were transferred to the 15 mL PP tube containing 150 mg of PSA and 300 mg of C18 sorbents. The tubes were shaken for 2 min and centrifuged at 10.000 rpm for 15 min. A volume of 2 mL extract was transferred into a screw cup vial and the extract was evaporated under a stream of N2 to dryness. The residues were dissolved in 100 μL of 20 % NaCl aqueous solution and 25 μL 3-MBPD solution plus 25 μL PBA solutions were added. The mixture was heated up to 90 °C for 20 min. After cooling, 0.5 mL hexane was added, the mixture was shaken vigorously and 200 μL of upper hexane layer was transferred into an insert of an autosampler vial. The extracts were analyzed by GC–MS. Each sample was prepared in triplicates.

2.5 Standard preparation

A series of standard solutions were prepared to dilute standard 3-MCPD and 3-MCPD-d5 mixtures in hexane at the following concentrations: 0.5, 2, 5, 10, 30, 40, and 50 ng mL−1. An appropriate volume of standard solution was prepared in a similar way to the samples. Each standard contained 25 µl of 3-MBPD solution and was prepared in triplicates. The calibration curve was constructed by plotting integrated peak areas, divided by the area of 3-MBPD, against compound concentrations.

2.6 Statistical analysis

The effect of storage time, packaging material, and sunlight exposure on 3-MCPD was determined by one-way and multivariate analysis of variance (ANOVA). p values of ≤ 0.05 were considered as significant. Intergroup differences were defined by the multiple comparison method of Tukey. All analyses were performed using Statistica 12.0 software (StatSoft Inc., Tulsa, OK, USA).

3 Results and discussion

The storage experiment was performed for blank and spiked samples separately. The necessity of fortification resulted from a low level of 3-MCPD in the tested samples, which changes during the study would be difficult to observe and evaluate.

The content of 3-MCPD determined in all investigated samples are presented in Table 2. We observed a decreased in 3-MCPD levels during storage in all analyzed cracker and biscuit samples. However, for blank samples of biscuits the obtained results were mostly below the limit of quantification (LOQ), established at the level of 10 µg kg−1. The rate of this decrease varied in crackers and biscuits and depended on storage conditions. In order to facilitate the assessment of 3-MCPD changes, the level expressed as µg/kg was re-calculated in percentage, with respect to the initial value established as 100 %. The percentage values are shown in Figs. 2 and 3. Additionally, multivariate analysis of variance was performed for the evaluation of the influence of storage time and packaging material, with the exception for blank biscuit samples because the levels were below LOQ. One way ANOVA was used for the significance assessment of storage time in relation to initial samples and to estimate the significance of exposure to sunlight. All statistical results shows Table 2.

Table 2 Content of 3-monochloropropane-1,2-diol in analysed samples
Fig. 2
figure 2

Changes of free 3-MCPD in crackers

Fig. 3
figure 3

Changes of free 3-MCPD in biscuits

3.1 Impact of time

Generally, the impact of time on the 3-MCPD level varied for blank and spiked samples of crackers (Figs. 2, 3). The statistical analysis showed that the storage time had a substantial impact on the 3-MCPD level, mostly in crackers (both blank and spiked) packed in paper bags. After 1 month of storage, there was no statistically significant changes in 3-MCPD levels compared to the initial content. After 5 months of storage, a significant decrease was observed for all samples except of sample 5CL (5 months, stored in polyethylene bag, exposed to sunlight; explanation of sample acronyms were given in Fig. 1 and Table 2). Changes in 3-MCPD content between 1 and 3 months, 3 and 5 months, and 1 and 5 months of storage were generally not significant, except for the samples 3CP-5CP (paper packaging), but the latter was noticed only for spiked samples.

In biscuits, there was a statistically significant decrease in 3-MCPD after 1 month of storage in all spiked samples, except for sample 1BL (stored in polyethylene bag, exposed to sunlight). Significant differences in 3-MCPD levels after 3 and 5 months of storage were noticed for all spiked samples. Changes between 1 and 3 months, 3 and 5 months, and 1 and 5 months were not big, apart for the samples 1BL-3BL, and 3BL-5BL (polyethylene bags, exposure to sunlight). For blanks, these findings were applied only in sample 3BL. For the rest of the blank samples, the results were difficult to assess due to low levels of MCPD.

3.2 Impact of packaging

The decrease rate in 3-MCPD level was higher in samples stored in paper bags than for those stored in polyethylene bags. The packaging had a significant impact on 3-MCPD decrease in both blank and spiked crackers (1CD-1CP, 3CD-3CP, 5CD-5CP), but the latter only in blanks. In biscuits, these differences were significant in the spiked samples 1BD-1BP, 3BD-3BP, 5BD-5BP.

3.3 Impact of sunlight

Sunlight did not have an effect on 3-MCPD levels in crackers, while there was a significant impact of sunlight on the decay of 3-MCPD in biscuits (5BL-5BD), but only after 5 months. This could be due to the fact that it was springtime during the storage period of 3 and 5 months and with that, more sunny days that could have contributed to a faster breakdown of MCPD.

Taking all observations together, the main conclusion is the 3-MCPD instability after longer storage times. These findings confirm previous reports in the literature on 3-MCPD instability in food (Breitling-Utzmann et al. 2005). However, in our study we discovered that 3-MCPD degradation rate depended also on storage conditions and on the content of 3-MCPD in samples as well. In case of lower content of 3-MCPD in the samples (both blank samples of biscuits and crackers and spiked samples of biscuits), the 3-MCPD decay was faster, while for spiked crackers with higher 3-MCPD content, degradation has been proceeding more slowly. However, in spiked crackers and biscuits we added 3-MCPD artificially to the samples. The added 3-MCPD could be more stable in crackers, probably due to the presence of NaCl. In biscuits, the degradation of added compound was similar to the one occurred naturally in the samples.

Apart from the 3-MCPD amount and storage time, the 3-MCPD decrease in crackers was mainly effected by the paper packaging. As for biscuits, besides storage time and paper packaging, the sunlight exposure had also a great impact on the decrease of 3-MCPD levels, but only in longer storage times, including sunny days. The difference between the changes of 3-MCPD levels in crackers and biscuits during sunlight exposition was the only differentiating factor in these 2 sample groups. This effect could be based on the sample ingredients. Crackers and biscuits were composed of similar water and fat, but varied in salts and sugars. This suggests once again that the presence of NaCl is a crucial factor contributing to 3-MCPD stability with inhibiting its degradation during exposure to sunlight.

The faster 3-MCPD decay in samples stored in paper bags might be due to the fact that paper is more susceptible to the absorption of fat, and the glycerol from fat is a precursor in the formation of 3-MCPD. According to another hypothesis, fat samples might have contained bound 3-MCPD in the form of esters, which might have decomposed over time, generating free MCPD. Absorption of fat with 3-MCPD esters by paper packaging could have inhibited the process of releasing free MCPD, in opposite to polyethylene bag.

4 Conclusion

To our best knowledge, the present paper is the first study concerning the free 3-MCPD stability in stored food. We conclude from our data that 3-MCPD in ready-to-eat cereal products is unstable during longer storage periods and gradually gets degraded. The largest decrease in 3-MCPD content was observed after 5-month storage in a packaging paper. In case of biscuits the decay of 3-MCPD was also significantly influenced by sunlight exposure.

These findings may contribute to extend the knowledge of the degradation mechanism of 3-MCPD in stored food products, but the practical aspect of the presented research is the possibility of decrease of the 3-MCPD level, for example by storing shortcrust pastry products packed additionally in a paper, if possible.