1 Introduction

In recent decades, demands for micromanipulation have increased in industrial assembly fields due to the nature of technology progressing to micro scales components assembly. Micromanipulation is the study of positioning micro-objects ranging from 1 to 100 µm in size. These micro-sizes can be a challenge task to manoeuvre without the use of micromanipulator tools due to additional attractive forces, viewing difficulties, high precision, and accuracy requirements (Adriaens et al. 2000; Yuan et al. 2015; Duc et al. 2006). To improve product quality and lead times, the use of robotic automation is being investigated to support micromanipulation equipment. There are two major techniques used for micromanipulation known as contact and non-contact methods, examples of these technologies are the electromagnetic fields, piezoelectric materials, electrostatic forces, electro thermal effect, shape memory alloys, magnetic guiding systems, and optical technologies (Nikoobin and Niaki 2012). These technologies can be utilised in the form of probes, needles, grippers and contactless devices. These methods have various advantages and disadvantages and are all at different stages of continuous development within research domain. The following section will discuss and review these methods.

2 Microgrippers

Microgrippers are commonly developed in order to manipulate micro-objects, such as microwires and microspheres. It has been stated that microgrippers are often the most suggested technology in use for micromanipulation, often due to their reliable accuracy, low cost, wide jaw aperture, and variable applied force (Nikoobin and Niaki 2012). All microgrippers are developed with different structure designs and different actuator types to control the gripper. A standard microgripper normally consists of a pair of gripping jaws, an actuator mechanism, and an amplification method (Long et al. 2017). Microgrippers have two major classifications based on their structure; cantilever and flexible hinge, these will be evaluated initially below.

2.1 Structure types of microgrippers

There are two different groups of structural designs for a microgripper; cantilever or flexible hinge. Both of these methods are used to ensure that the arms of the grippers are capable of opening and reverting back to its original positions. The structure suitability is dependent on the shape and size of the object to be grasped. The design of cantilever microgrippers are built around each arm being fixed at the base, whilst a form of actuator forces the material to bend apart or together, causing the structure to flex (Haddab et al. 2000; Suzuki 1994; Du et al. 1999; Jain et al. 2015; Giouroudi et al. 2008). This form of structure results in a mechanical stress being distributed throughout the material as a force is applied to it. It is then the elastic potential energy within the material of the cantilever that ensures that the structure springs back to its original position. The flexible hinge structured microgripper are often more advanced and contain complex designs. They are commonly developed using computer modelling and mathematical analysis methods (Zubir et al. 2009). The design of the majority of flexible hinge microgrippers available are described as monolithic due to being manufactured out of a single material and are often produced using microfabrication techniques (Zubir et al. 2009). This is one advantage over cantilever structures as they are capable of being scaled down to a size of 33 mm × 9 mm × 3 mm and are capable of manipulation smaller sized objects, whereas cantilever structures can only be used to manipulate larger objects however they may apply excessive force to the object (Yang and Xu 2017; Kawamoto 2009). The most important element of this type of gripper are the flexible hinges themselves. These sections of the structure are comprised of thin sections of the material and hence the most susceptible to bending. These features ensure that the stresses of the structure are concentrated within certain point whilst the other sections of the structure remain rigid. This can be advantageous in various aspects of the microgripper use.

Various shapes of hinges have been studied in previous literature. Circular notch hinges are an increasingly popular design of flexible hinge as studied in previous literature (Liang et al. 2018; Wang et al. 2013a, 2015; Kyung et al. 2008; Nah and Zhong 2007; Shi et al. 2018; Keoschkerjan and Wurmus 2002). This type of flexible hinge contains many advantages including being capable of achieving a large defamation prior to exceeding the tensile yield limit of the material being used. The use of a circular hinge also ensures a more precise and constant point of rotation along its axis throughout the deflection process (Keoschkerjan and Wurmus 2002). The flexible circular hinges are designed to closely mimic ideal hinges thus creating maximum displacement at the tips due to the minimum stiffness of each hinge. This hinge design also ensures high position accuracy and repeatability of the movement of the jaws of the microgripper due to the circular structure of the hinges.

Another common shape is flexible leaf hinge which is capable of producing large displacements of the jaw tip, along with a reduced experienced stress along each hinge due to the larger area of where the stress is dispersed. However, due to the lack of circular rotation, the accuracy of the system decreases (Qingsong 2015; Beyeler et al. 2007; Qu et al. 2017). The advantages of the flexible leaf hinge do not however justify its use as the most important required feature is the accuracy. There are differences between the operating jaw angles of each structure type. Firstly, as a force is applied to the arms of a cantilever material the length of it bends, therefore the angle of each jaw will change whilst open and closed. In this situation, this angle change may be problematic, especially when attempting to manipulate objects with curved edges such as microwire or microspheres. The flat edges of a two-armed gripper may not be parallel to each other when closed around the object, causing an inadvertent force applied to it. This results in an insecure grasp of the object and may lead to its unintentional release. On the other hand, flexible hinge microgrippers are often a monolithic structure and are designed to ensure that the jaws remain parallel during the gripping process (Zubir et al. 2009). This is beneficial when attempting to manipulate a wide range of object shapes and sizes. A commonly used structure design to ensure this parallel movement is described as a parallelogram shaped flexible hinge structure. It often comprises of four flexible hinges and two rigid beams per arm. As the arm is actuated, the beams remain parallel and hence ensure that the jaws remain parallel. The flexible hinge designs have the advantage of a greater position repeatability and accuracy. Various types of monolithic flexible hinge grippers have been studied along with the different configurations available to produce a flexible hinge with a large jaw aperture (Nah and Zhong 2007; Beyeler et al. 2007; Qu et al. 2017; Cauchi et al. 2018). Prior research has suggested to employ the corner fillet hinge design to enable the maximum change in jaw tip displacement (Zubir et al. 2009). The advantages and disadvantages of both structures are displayed in Table 1. Along with the chosen structure of a microgripper, it is essential to consider a suitable technology which is used to apply force to the gripper to enable it to open and close. These are referred to as actuators and are further analysed in the next paragraph.

Table 1 Advantages and disadvantages of different microgripper structures

2.2 Actuator types of microgrippers

When developing a microgripper, the choice of actuator remains an important part of the process. The actuator is the component of the microgripper which applies force to the structure to enable the jaws to open and close. Throughout the development of microgrippers, various technologies have been trialled to find the most suitable type of actuator, such technologies include; piezoelectric (Fig. 1) electromagnetic (Fig. 2), electrostatic (Fig. 3), electro-thermal (Fig. 4), and shape memory alloys (SMA) (Fig. 5). A literature report published an algorithm which described the design process of a microgripper (Nikoobin and Niaki 2012). Within this report, the variables that were capable of affecting the design requirements of a microgripper were highlighted, such as jaw aperture, shape of jaw, and actuator type (Nikoobin and Niaki 2012). A state of the art review was published afterwards, which describes the use of different actuator types used within microgrippers (Jia and Xu 2013). Discoveries from the paper and other research are explained in the next five sections of this review. The types of actuators will be evaluated by comparing the advantages and disadvantages for each (Table 2).

Fig. 1
figure 1

Image of a monolithic microgripper actuated using stack piezoelectric material, developed by Haddab et al. (2000)

Fig. 2
figure 2

Image of a cantilever style microgripper actuated using an electromagnet, developed by (Giouroudi et al. 2008)

Fig. 3
figure 3

Electrostatic comb structure developed by Chen et al. (2009)

Fig. 4
figure 4

Electro-thermal U-shaped microgripper developed by Kolahdoozan et al. (2017)

Fig. 5
figure 5

Shape memory alloy actuated cantilever microgripper developed by Munasinghe et al. (2016)

Table 2 Comparison of the main advantages and disadvantages of different actuator types collaborated from the literature above

2.2.1 Electromagnetic microgrippers

Electromagnetic actuated microgrippers utilize electromagnets to open and close the jaw of the gripper. This type of microgripper is often utilized in the form of a cantilever style gripper as presented in Kim et al. (2005). The most common assembly of this actuator type is to place the electromagnet in the centre of two magnetic arms and jaws. Electrical current is conducted through the electromagnet and as it is increased, the magnetic arms are attracted towards it and the aperture size of the gripper tips decreases. Development and experimental trials have been carried out on this type of gripper. An electromagnetically actuated microgripper was developed that is capable of producing a maximum jaw gap of 250 µm (Liaw et al. 2008). Trials of the gripper consisted of testing the grasping technique on a 50 µm metal wire and a 125 µm glass fibre. Manipulation of both objects were successfully gripped without errors in release or accuracy. The gripping force of the system was adjustable with an alteration of the electromagnet current, producing a maximum gripping force of 130 µN (Liaw et al. 2008). However, concerns were noted about this system regarding to heating problems. While the microgripper was in operation its metallic components, manufactured using cold laser cutting, were noticed to increase in temperature from 27 to 38 °C over the course of a half hour where the length of the gripper arm increased by approximately 0.1 µm/°C (Liaw et al. 2008). This causes problems over time as the position and accuracy of the gripper may become unknown and will produce errors during the manipulation process. A similar gripper was developed with the intention of becoming an automated system for the purpose of manipulating a microwire (Ruiz et al. 2018). The gripper jaw had a cantilever structure using electromagnetic actuator. The gripper system was developed in order to manipulate a 50–70 µm diameter copper wire and move it to a desired position (Ruiz et al. 2018). The research trialled various arm lengths and jaw angles of microgripper and recognised the disadvantages of using a long tip as it reduces the clamping force available to grip the wire (Ruiz et al. 2018). Further experiments were carried out using different weight of objects at different orientations. The results concluded the microgripper’s capability of manipulating the copper wire as required. Despite these successes, one report claims that producing a microgripper with an electromagnetic actuator is not preferable due to the complexity of the structure and the negative interference from external electromagnetic fields (Haddab et al. 2000). An additional disadvantage was that these types of microgrippers are often heavier than others due to the components required and may slow down the manoeuvring process and reduce the systems precision (Haddab et al. 2000). These actuator types are agreed to be able to produce a large jaw movement and gripper force which is ideal for larger object. However, due to the structure and components required it is difficult to scale down and hence a limitation for micromanipulation (Kolahdoozan et al. 2017).

2.2.2 Piezoelectric microgripper

Piezoelectric materials are a type of material that is capable of changing its shape when an external electrical voltage is applied to it. This form of technology has recently been utilised to produce an actuator for use within microgrippers as shown in Wang et al. (2015), Liaw et al. (2008), Ruiz et al. (2018) and Conway and Kim (2004). These actuators have been researched for uses in many different industrial fields such as medicine, robotics, space exploration and semiconductor fabrication (Long et al. 2017; Zubir et al. 2009; Beyeler et al. 2007; Chen et al. 2009). Piezoelectric grippers have been proven to be a suitable end-effector type capable of precisely manipulating small objects (Rakotondrabe and Ivan 2011). When compared to other gripper technologies, piezoelectric gripper have advantages that include: compact design, light weight structure, low energy usage, unaffected by electromagnetic fields, predictable displacement, high precision, fast response time, large bandwidth, no slip effect, high gripping force and a high force to weight ratio (Xu 2014). Multi-layer piezoelectric materials are often used to produce a large jaw displacement and high force when compared to a single piece of piezo materials, therefore multi-layer stacking is used in the majority of piezoelectric actuators (Yang and Xu 2017; Wu and Xu 2018). Piezoelectric microgrippers have been proven to grip objects with a size as low as 15 μm (Haddab et al. 2000). The work was focused on developing a system that was capable of accurately grasping and manipulating microwires (Haddab et al. 2000). The report stated that the gripper was able to achieve a maximum jaw aperture size of 170 µm (Haddab et al. 2000). This size of jaw was suitable to grasp a large range of the wire diameters and micro-object sizes. The amplification ratio for the system was found to be 17.14 (Haddab et al. 2000). A three-stage, flexible hinge structure was designed to produce a large tip aperture (Wang et al. 2015). Each jaw of the gripper was capable of a 95 µm displacement and had a 22.8 amplification value from the input displacement of the piezoelectric actuator (Wang et al. 2015). The gripper was tested by successfully gripping a 25.4 µm diameter gold wire. The maximum jaw gap was 190 µm while applying a voltage of 100 V (Kawamoto 2009). Moreover, using the piezoelectric material to produce a cantilever style microgripper was suggested to reduce the weight and complexity of the structure although it would also reduce the applied force (El-Sayed et al. 2013). Each cantilever was structured as a bimorph, by bonding two layers of piezoelectric materials together and therefore flexed due to the expansion of one material. The aperture size of the gripper tips was measured using a non-contact proximity sensor and results demonstrated that the gripper was capable of handling an object with a width of 50 µm whilst the tip deflection reached a value of 520 µm (El-Sayed et al. 2013). Another similar gripper fabricated from an aluminium plate and capable of ensuring that the system had high precision and also that the jaws remain parallel by using the parallelogram flexible hinge structure. Through practical experimentation, it was established that the gripper had an amplification of 3.68 and the jaw aperture was able to reach 100 µm (Zubir et al. 2009). Wang et al., developed a monolithic piezoelectrically driven gripper which embedded a force and tip displacement sensor to supply feedback (Wang et al. 2013a). Each tip was able to move a maximum distance of 18 µm when a voltage of 200 V is applied (Wang et al. 2013a). The coarse displacement of the jaw gripper is altered by adjusting a screw attached to the gripper (Wang et al. 2013a; Nah and Zhong 2007). The amplification of the gripper was measured to be around 16 (Wang et al. 2013a). The gripper design created the ability to move the jaws parallel to each other whilst achieving a large jaw aperture of at least 230 μm (Wang et al. 2013a). The practicality of this microgripper was proven by grasping an optical fibre of this diameter (Wang et al. 2013a). One reported stated that the researchers successfully produced a flexible hinge style gripper that was capable of gasping and releasing object of a size range between 100 and 800 µm, which is a very large range compared to other grippers (Nah and Zhong 2007). However, this is due to the use of a pre-adjusting system and the microgripper had a maximum jaw tip displacement of 170 µm. The gripper with a monolithic design, had an amplification value of 3 and was designed to ensure that the jaws move in parallel to each other (Nah and Zhong 2007). The gripper was capable of grasping and releasing a 500 µm diameter Teflon wire (Nah and Zhong 2007). Furthermore, it was also detailed that the microgripper had the potential to be scaled down further, making it more suitable to manipulate objects with a size less than 100 µm, but this theory will need to be further proved experimentally (Nah and Zhong 2007). Manipulating object as small as 10 µm have be proven to be achievable through manipulating a 10 µm diameter polystyrene ball and a 100 µm diameter human hair proving that this design of microgripper is capable of grasping, not only cylindrical, but also spherical micro-objects of a very small size (Shi et al. 2018). A compliant microgripper capable of producing a jaw gap of 280 µm was developed in Xu (2014, 2018). The initial jaw gap of the gripper has the potential to be adjusted and was therefore experimentally capable of manipulating 300 µm diameter copper wire. The gripper could apply a force of around 20 mN to an object (Xu 2018). In the majority of reported work, it is displayed that as the jaw gap decreases, the force applied by the jaws also decreases. However, one researcher developed a piezoelectric actuated microgripper that was able to apply a constant force to an object (Xu 2014). The microgripper was able to apply the constant force by use of a passive stiffness mechanical structure which is triggered when the desired force on the object is reached (Xu 2018). The fabricated microgripper was able to produce a jaw aperture of 220 µm and produce a maximum of 530 mN of force on an object (Xu 2018). A recently published paper describes the design of a monolithic gripper that utilizes the movement of only one gripper jaw (Wang et al. 2015). This piezoelectric actuated microgripper has been developed in this manner to increase the precision of the gripper. When a conventional two moving jaw microgripper grasps hold of a micro-object, the jaws of the gripper often dis-align from a central position and thus effect the consistence and accuracy of the system (Liang et al. 2018). The single movable jaw structure comprises of a moveable jaw and a fixed jaw. During the gripping process the micro-object will be held by both jaws, however the fixed jaw will remain in a constant position before and after the process and hence is a relatable constant point of the jaw (Liang et al. 2018). The microgripper also comprises of three different amplification systems from the piezoelectric material to the gripper jaws, which converts a small displacement from the material to a large jaw tip displacement of 75 µm (Liang et al. 2018). Another survey reviewed a large quantity of various microgripper actuators and concluded that the piezoelectric actuated microgrippers studied were capable of producing jaw displacements between 16 and 8800 µm while the applied voltage ranged from 0 to 700 V for different microgrippers (Dochshanov et al. 2017). The force from the tips varied from 1 µN to 1.87 N. And the amplification factor of the studied systems ranged between 2.85 and 50 (Dochshanov et al. 2017). This displays that piezoelectrically actuated microgrippers can be used to manipulate a wide range of object sizes. Throughout the research of this type of technology, various limitations have been discovered including: hysteresis properties of the material, amplification discrepancies of the jaw aperture and inaccurate position placement of jaws (Shi et al. 2018; Beyeler et al. 2007; Qin et al. 2013; Grossard et al. 2009). One report presented the development of a monolithic piezoelectric gripper which had a maximum applied voltage of 150 V and a change in jaw tip position of 65 µm (Shi et al. 2018). These researchers noticed that the two jaw arms did not display the same displacement and stated that this could have been due to fabrication variation or incorrect alignment of the piezoelectric material (Shi et al. 2018). Another researcher declared that any fabrication inaccuracies such as this must be reduced to ensure that the microgripper jaws achieve a high accuracy (Ruiz et al. 2018). Limitations were also found in another survey where it was found that using a piezoelectric actuator, the jaw position movements were lower in comparison to other actuator types and a hysteresis issue also noted (Jia and Xu 2013). Another report produced a mathematical model that described the deflection and force values of a piezoelectric actuator (Grossard et al. 2009). They also proved the model experimentally by developing a microgripper with this actuator. The tip displacement of the microgripper prototype was said to be 1.5 mm with a force of 0.203 N, where the maximum applied voltage was 60 V (Grossard et al. 2009). It was also discovered that a hysteresis error in the tip of the gripper occurred causing the tips of the gripper to follow different paths whilst opening and closing. This error was successfully reduced by controlling the voltage with a proportional derivative controller which reduced the error of the path from 0.2 to 0.02 mm (Grossard et al. 2009). The same researchers continued their study in 2015 and trialled the microgripper to pick up a 1 mm diameter pin and place it into a hole (Jain et al. 2015). The hysteresis error was again studied and a deflection error of 116 µm was produced when comparing the opening and closing paths of the gripper (Jain et al. 2015). The proportional-derivative controller along with a laser position sensor was able to reduce this error and resulted in the successfully placement of the pin (Jain et al. 2015).

2.2.3 Electrostatic microgripper

Electrostatically actuated microgrippers are utilised by applying a positive and negative voltage to two elements of the microgripper which then attract or repel each other due to the electrostatic force created. The structure of these microgrippers are frequently found in literature to be in a comb formation, which consists of two interlocking combs (Kalaiarasi and Thilagar 2012). As a voltage is applied to the combs, an electrostatic charge is produced, and the combs either attract or repel. This structure is integrated with a set of jaw, which enables them to open or close. The structure is easy to fabricate, requires a low voltage, can produce a large tip deflection (e.g. 70 µm, Table 3) and has a faster response to a change of voltage in comparison to other methods, such as electro-thermal (Yang and Xu 2017). In the 2013 review by Jai and Xu, it was described that the benefits of using an electrostatically actuated microgripper are that it can obtain a large jaw aperture change whilst producing no hysteresis effects which produces a predictable response (Jia and Xu 2013). Another report researched electrostatically controlled microgrippers with the capability of manipulating a micro-object from 0 to 100 µm between the voltages of 0 and 33 V respectively (Yuan et al. 2015). This report developed a novel mechanism for the gripper to self-lock whilst operating, which enabled the gripper to hold an object for a long time without the need to apply voltage during these periods (Yuan et al. 2015). The benefit of this is to ensure that the gripper does not caused unnecessary stress or damage on the object and further reduces the amount of energy used by the microgrippers (Yuan et al. 2015). The system was trialled by successfully holding a metal wire with a diameter of 40.6 µm (Yuan et al. 2015). Electrostatically actuated grippers have been integrated with jaws where the applied force can be precisely controlled (Chen et al. 2009). This gripper was additionally developed to have three tweezers within the gripper to enable the system to grasp a wide range of object (Chen et al. 2009). The grippers themselves were controlled using electrostatic forces, the force sensors utilize piezoelectric materials to detect the force that is being applied to the object (Chen et al. 2009). Each arm tip is capable of a 25 µm deflection although the system as a whole can manipulate objects between 30 and 130 µm (Chen et al. 2009). The gripper was trialled on a variety of sized polystyrene microspheres of sizes between 30 and 80 µm (Chen et al. 2009). It was measured that a force of 350 μN and 100 μN were applied to the object, with the driving voltage of 75 V and 58 V respectively (Chen et al. 2009). In the medical industry, different types of piezoelectric actuated microgrippers have been developed and utilised. It was suggested that micro-technological devices such as microgrippers can be used to assist in minimally invasive surgery and other challenging scenarios regarding to technicality and small-scale sizes (Gaafar and Zarog 2017). One type of gripper developed in 2017 contained a comb structure described above and different types of materials were studied for use in the conducting and insulating components of the gripper (Gaafar and Zarog 2017). The applied voltage was of 100 V with the displacement of the two material types of 19.66 µm and 32.5 µm, this highlights that the choice of material is an important factor to consider (Gaafar and Zarog 2017). Another form of electrostatically actuated comb driven microgripper was developed in 2012 where the researchers simulated the grippers with various shapes of combs (Kalaiarasi and Thilagar 2012). The trialled shapes included a square notch, a 2 stepped notch, small v-shaped notch and large v-notch. From the shapes suggested, the large v-shaped notch produced the greatest jaw tip displacement of 6.66 µm and 21.25 µm with voltages of 14 V and 25 V respectively (Kalaiarasi and Thilagar 2012). However, the jaw displacement of this microgripper was significantly less than other structures, therefore it should be noted that the applied voltage in this design is furthermore less compared to others, resulting in a decrease in energy consumption. Another survey stated that the electrostatic actuated microgrippers reviewed, showed various jaw displacement ranges between 2.5 and 275 µm, with an applied voltage range between 0 and 185 V, a force from the jaws of 4 nN to 2.5 mN and an amplification factor between 4 and 5.9 (Verotti et al. 2017). The jaw displacement ranges of these electrostatically actuated microgrippers are able to achieve smaller jaw displacements compared to the piezoelectric actuated grippers as above. This suggests that electrostatic actuators are better suited to manipulate micro-objects within the range of 1–100 µm in compared to other microgripper actuator types. However, there are operational limitations such as requiring a high operating voltage to produce a high jaw displacement, unable to achieve high gripper forces and large structure sizes (Jia and Xu 2013).

Table 3 Various researched microgripper types with a comparison of their main characteristics

2.2.4 Electro-thermal microgripper

The method behind electro-thermal actuators is based on the phenomena that as current is passed through a conductor, it will cause it to increase heat and results in an expansion of the material. This is often utilized within microgrippers and is used to open and close its jaws. These microgripper types are often fabricated with a monolithic structure and usually created using the chip manufacturing process (Kolahdoozan et al. 2017; Wu and Xu 2018). It is also capable of producing cantilever structures using this method by utilizing bi-metallic strips. The advantages of using this form of actuator is the capability of producing a larger gripping force and jaw displacement while low voltages are applied (Jia and Xu 2013). With regards to materials used to manufacture the microgrippers, it has been stated that silicon, stainless steel and high grade aluminium alloys are common choices for electro-thermally actuated microgrippers (Nikoobin and Niaki 2012). Monolithic electro-thermal microgrippers often come in three structures: U, V and Z-shaped. The most common form is the U shaped structure and is designed so that each arm comprises of two parallel, but separately insulated beams, only one of which is heated by an applied current, due to this, the tip of the arm flexes away from the heated stem (Yang and Xu 2017; Chronis et al. 2005; Zhang et al. 2013; Zhang et al. 2011). It has been stated that grippers of this structure are capable of producing a displacement of up to 262 µm with an applied voltage of 1.94 V (Yang and Xu 2017). The V shaped structure contains a central component suspend from two thin lengths of material in a V shape (Yang and Xu 2017). As the material is heated, the central component will move a predictable distance. It has been stated that this structure is capable of achieving a movement of 173 µm with an applied voltage of 1 V (Yang and Xu 2017). The Z structure actuator utilises the same method as used in the V shape structure however the two suspending materials are shaped in a Z-notch formation and produces a linear movement of the central component capable of moving it 80 µm with an applied voltage of 6 V (Yang and Xu 2017). Another paper described the utilisation of the electro-thermal effect to actuate a novel design of microgripper which comprised a series of D-shaped loops placed consecutively between the actuator arms and the gripping tips (Bordatchev and Nikumb 2003). As a current was applied to the structure, the D-shaped loops would increase in temperature and hence expand, causing the jaw aperture to decrease. The microgripper was capable of producing a jaw aperture between 98.4 and 71.8 µm with applied current of 0.32–0.84 A respectively, although the writers stated that a larger gap would be achievable by improving the gripper design, however it was not stated what improvement would be implemented. To incorporate the high range capabilities of an electro-thermal actuator, but also utilize the high speed and precision accuracy of a piezoelectric actuator, a hybrid actuator microgripper has been previously fabricated (Rakotondrabe and Ivan 2010). The structure of the arm used a dual layer cantilever comprising of a piezoelectric layer and a passive layer. When heat is applied to it, it is capable of deflecting distances higher than 100 µm for each arm, resulting in a total jaw aperture of at least 200 µm. However, while actuated by the piezoelectric system, each arm was capable of deflecting a distance of approximately 15 µm. The system used the electro-thermal actuator to coarsely guide the cantilever tips to the object to be grasped, from there the piezoelectric actuator could finely adjusts the tips to hold the object. The disadvantages of the system is the complexity of having to provide a feedback system which incorporates data from both actuator types, however this was solved in the paper (Rakotondrabe and Ivan 2010). This report stated that electro-thermally actuated microgrippers produce a larger jaw displacement of around 55 µm and large gripping force whilst using low voltages of 1–8 V (Elsen et al. 2019). Results from the report showed that the response of displacement to the applied voltage was exponential (Qin et al. 2013). This type of microgripper often produces a non-linear opening and closing whilst using high temperatures, therefore the design of the structure needs to be carefully considered to ensure that the desired gripping aperture can be reached (Jia and Xu 2013). However, in many applications a linear response may not be required during operation times, hence this limitation would not be an issue. One of the main limitations of electro-thermally actuated grippers is with regard to the amount of heat generated by the gripper in order to alter its jaw aperture size (Jia and Xu 2013). This is often undesired as it may result in exerting heat to the object that is being manipulated and may subsequently cause damage. One paper explains the development of a novel design of electro-thermal gripper that is based on a U-shaped style of microgripper (Fu et al. 2012). The report states that the design presented is less complex than other electro-thermally actuated structures and also states that the structure is capable of achieving predictable jaw movement with a certain applied voltage (Fu et al. 2012). The jaw displacement for the gripper was said to be 10.072 µm while the voltage applied was between 1 and 10 V (Fu et al. 2012). It was also stated that the maximum temperature of the arms reached a value of 224 °C, although the temperature value at the tips was not able to be measured due to equipment limitation (Fu et al. 2012). The temperature of the tips must often be considered and measured during operation, as high temperature may cause damage to micro-objects during the manipulation process. An electro-thermal actuated microgripper produced was capable of achieving motion along two axis, which was stated as being a first in research (Qu et al. 2017). The gripper also integrated a capacitive force detection system capable of measuring the amount of force applied to the gripper jaws (Qu et al. 2017). The researchers also noted that heat conducting along the tip may also cause micro-object damage (Qu et al. 2017). Within the medical industry, microgrippers have been designed to manipulate red blood cells. An electro-thermal microgripper developed was able to produce a jaw displacement of 9 µm, which was said to be the value desired to manipulate the blood cells (Cauchi et al. 2018). The difficulty with attempting to use an electro-thermally actuated microgripper to manipulate biological matter is that the heat produced by the gripper has the potential to cause damage to the subject. It is also important to ensure that the maximum temperature produced by the microgripper does not reach the limiting temperature values of the materials of the microgripper itself, hence causing inherent damage. The gripper designed in this report was based on a U-shaped structure. To ensure that heat did not conduct through the gripping arms, each included a structure comprised of a thin sheet of material, the width of the gripper, which contained a matrix of holes throughout in order to dissipate heat. A simulation of the structure showed that although the maximum temperature of the structure reached 267 °C, the tips of the gripper remained at room temperature, proving that this structure would not apply excess heat to the micro-object (Cauchi et al. 2018). A survey stated that after reviewing a vast amount of electromagnetically actuated microgrippers, the jaw displacement range are found to be between 1.2 and 260 µm, the applied voltage is between 0.1 and 90 V, exerted force from jaws between 20 µN and 135 mN and amplification of 1.731–100 (Dochshanov et al. 2017).

2.2.5 Shape memory alloy microgripper

Shape memory alloys (SMA) can change their characteristic features when heat is applied. The material is capable of transforming its shape and size whilst at high temperatures and further returns to its original position when the heat is removed (Kawamoto 2009). This ability has been utilised for producing actuators for microgrippers as displayed in Kawamoto (2009). It has been shown that SMA actuated microgrippers are able to produce high jaw displacement values and gripping force. Although a delayed reaction is produced when voltages are applied in compare to other gripper types. One review has stated that using Nickel–Titanium material to create SMA actuated microgrippers has been proven to be very successful as it has the ability to produce a high gripping force and jaw tip displacement at temperatures around 60–80 °C (Fu et al. 2012; Choudhary and Kaur 2016). A microgripper actuator review from 2012 revealed that SMA actuators are commonly studied due to the high energy density available, resulting in the potential for the technology to be scaled down to microscales (Fu et al. 2012). One researcher developed a SMA actuated microgripper with three degrees of freedom and was capable of positioning the gripper jaws along the x and y axis (Abuzaiter et al. 2016). The structure consisted of three bimorph SMA sections. The first was connected to a base of the gripper and a strip of SMA material was able control the bending of the remaining structure along the x-axis. The second element, connected to the first, was another strip of SMA material which enabled the final section to be moved along the y-axis. The final section, the gripper itself, is made up of two SMA elements creating a cantilever-type gripper structure. These elements are able to flex and result in opening and closing of the gripper jaw and grasping hold of an object. Each SMA strip is controlled by independent circuits that conduct a current through each strip creating heat and subsequently flex (Abuzaiter et al. 2016). Experiments conducted trials using different thicknesses of SMA and silicon dioxide materials of the bimorph strip to achieve the greatest displacement (Abuzaiter et al. 2016). The maximum displacement of the first and second sections of the device reached 7.1 mm (Abuzaiter et al. 2016). The system was practically trialled and successfully manipulated a small object. Limitations of the developed microgripper included a time delay of approximately 10 s which occurred when actuating the bimorph strips. Furthermore there is a hysteresis issue when heating and cooling each strip (Abuzaiter et al. 2016). Another developed microgripper had an SMA actuator that was fabricated using nickel titanium material with silicon as presented in Lin et al. (2009). The materials were configured into a spring structure to produce a large jaw size of 120 µm. The springs were connected between a solid structure and to the middle section of cantilever arms. Using the same methods as previous reports, heat was applied to the SMA nickel titanium springs by supplying an electrical current which caused the springs to expand, resulting in the closure of gripper jaws (Lin et al. 2009). The silicon springs were put under tension and once the current supplied to the SMA springs is removed, the silicon springs caused the gripper jaws to open. This report stated that the advantages of using SMA actuators are that they supply high gripping forces, precision and response times (Lin et al. 2009). This last statement contradicts other reports that have stated slow actuator response times. However, this report has not stated the expected time delay of the developed microgripper. Researchers have also investigated the use of SMAs in the form of wire (Kyung et al. 2008; Jia and Xu 2013). This has been accomplished by creating a monolithic flexible hinge microgripper structure and utilizing SMA wires connected to the base. The gripper arms of the structure open and close the jaws as the temperature of the wire is altered (Kyung et al. 2008; Jia and Xu 2013). Another method utilizing SMA wires produced a cantilever type structure which was actuated by the wires (Raparelli et al. 2018). The research developed a gripping arm to have several staggered sections which were used to connect each separate length of SMA wire. This gripper was developed with this feature to produce a large jaw gap change. Another SMA wire actuated gripper was developed and manufactured (Wagner et al. 2008). The structure was manufactured out of silicon whilst a 50 µm diameter SMA wire was utilized to close the jaws. The design of the structure used a four-bar mechanism, this parallelogram linkage structure ensures a parallel movement of the gripper tips (Wagner et al. 2008). Due to the small dimensions required for the microgripper it is not desirable to use physical hinges for the mechanisms (Wagner et al. 2008). Therefore, the gripper structure was initially developed with flexible hinges, however in the finite element model it could be noted that the majority of the structure had no applied stresses and a vast amount of stress were produced at the hinges. It was stated that this was not preferred and to utilize the material, it would be ideal to ensure that the stresses were dissipated throughout the entire structure (Wagner et al. 2008). To achieve this, the structure was re-designed, and the flexible hinges were removed. Instead, the four bars of the structure were reduced in width to produce four thin beams, twice as thick as the original hinges (Wagner et al. 2008). After completing another finite element test on the amended structure, it displayed that the stresses were now distributed throughout the thin beams. This method increases the durability of the structure. The design of microgripper was theoretically able to produce a large jaw displacement range, however the SMA wires that were experimentally used were not the preferred choice and hence produced less force than required whilst actuating (Wagner et al. 2008). This inevitably lead to a smaller jaw tip displacement that expected. However, there are also various limitations related to this technology particularly when using Nickel–Titanium material for its fabrication. These limitations include inefficient energy usage, slow response, high heat during operation and hysteresis and fatigue issues (Choudhary and Kaur 2016; Nemat-Nasser and Guo 2006; Yang et al. 2017; Rubio et al. 2009). Another limitation of this system is that the response given by the material is often unpredictable, which often leads to the actuator producing unknown positions whilst between the open and closed states (Fu et al. 2012).

3 Robotic actuators in medical industry

3.1 Medical robotic systems

Surgical robots for use within the medical industry has been thoroughly reseachered over the past few decades. Extensive research has been conducted into use of various types of surgical robots along with medical tools and actuators associated with the system. An increasing amount of research has been conducted into mechanical medical grippers, particularly with regards to minimally invasive surgery (MIS) and the need to manipulate delicate parts of the body such as blood vessels which have a diameter of less than 1 mm. Medical microgrippers have been produced because of this and are particularly accurate and precise due to the medical nature. The majority of surgical robots are non-autonomous and currently require a surgeon to control the tools of the system. Robotic systems used for MIS comprise of a set of tools, often grippers, and a vision system which is controlled from a console situated away from the patient. Surgical robots have been developed in order aid surgeons during surgery and to reduce the amount of trauma induced to a patient. In 1995, a system called Zeus was developed which held various tools for an operation and was capable of mimicking the controls of the surgeon whilst increasing accuracy by reducing the surgeon’s tremors and converting the surgeon’s motions into small precise movements within the patient (Beasley 2012). One of the most commercially available robotic surgery systems is the Da Vinci system which was first available in the year 2000. This system contains three to four flexible arms that are used to control multiple types of tools to be used for MIS. The tools often include grippers which have two degrees of freedom (Beasley 2012). One report researched into the force response from various tools used by the system. It was discovered that whilst the different tool arms exerted the same gripping force, different tools exerted a wide range of forces, declaring that appropriate tools must be selected throughout an operation process depending on the task required (Mucksavage et al. 2011). Another system named Telelap ALF-X, comprises of four arms and is similar to the Da Vinci system, but also includes a haptic feedback system with an accuracy of 35 g (Beasley 2012). The benefit of the feedback system is that the surgeon can approximately detect the amount of force being applied by the grippers of tools and hence prevent damage to the patient. The system has been successfully trialled on animals and stated to have reduced operating times compared to other systems (Beasley 2012; Stark et al. 2012). The Raven surgical robot is a system similar to above and contains two tool arms and the system has seven degrees of freedom (Lum et al. 2009). This report tested the system using various experiments, predomintly for the study of the network effect on the system. When compared to traditional surgery methods, the above stated surgical robots have a reduced field of vision as the surgeon often views the procedure using only one or two cameras, also the remote end-effector system reduces the degrees of freedom that the surgeon can manipulate (Beasley 2012; Gomes 2011; Dogangil et al. 2010; Kuo and Dai 2009). It was found in a study that a large amount of errors caused by surgeons during traditional surgery were related to applying excess force to a patients tissue (Jin et al. 2016; Tang et al. 2004). Due to this, force sensors are commonly researched to integrate with the surgical robots as presented in the Teleap ALF-X system. The above stated systems are all non-autonomous and require surgeon control. The idea of autonomous force control has been disregarded by many as the intended force required within a patient is often variable and hence unknown (Harada et al. 2011). It seems that fully automated surgical robots will still require further research to be capable of assisting with surgical procedures. They currently would not be suitable due to the primitive systems that provide haptic feedback. Assisted robotic tools are more likely to be used as a surgeon would be on hand to conduct and analysis the procedure.

3.2 Types of grippers

Traditional methods for surgical operations use various tools that are often classified into six groups, cutting, grasping, haemostatic forceps, retractors, clamps and implants (Jin et al. 2016). Several of these tools involve a form of gripper to hold an internal part of the body. Various gripper types have been developed depending on the medical requirement, whether it involves grasping layers of tissue to manoeuvre or blood vessels to prevent blood loss. The surface of gripper jaws is often either smooth faced or tooth faced depending on the desired task. It has been stated that tooth formation grasping tools can cause an uneven distribution of force along a layer of tissue and hence result in additional force being applied in certain locations, often causing damage (Jin et al. 2016). It is suggested that numerical simulations are performed to assess the force applied by the gripper to ensure a uniform force is applied. A report by Xu et al. (2009) presented a design of a cable-actuated medical gripper capable of reaching high 40 N gripping force whilst also producing a wide jaw angle (Xu et al. 2009). These successes were reached by producing a hinge comprised of two slopes, one steep slope to produce the large gripping force, while the shallow slope ensured that the jaw can reach the wide angle (Xu et al. 2009). The jaw faces of the gripper were designed with teeth structures to increase the gripping force that could be applied. This type of design is advantages when attempting to grasp various objects with different sizes with different forces.

3.3 Transmission systems

Different forms of transmission systems have been studied for use in surgical robotic systems between controller and gripper, such transmission systems use include cable, fluid, smart material and magnetic. Each of these types have been stated to have multiple advantages and disadvantages with continuing research being conducted for each. Cable-actuated systems are capable of producing high gripping force however they often involve complicated and expensive fabrication processes, hysteresis issues and a short life-span of ten surgical procedures due to the repetitive bending of the system (Le et al. 2016). Fluid-actuated transmission systems are able to supply a high force particularly at microscale and also achieve large bending angles, on the other hand they also involve a complicated system, require a high power supply and have hysteresis issues (Le et al. 2016). Another form of actuator uses shape memory alloys which are capable of applying a large force and displacement, but also can apply the force along three axis (Le et al. 2016). This form of transmission however has a low frequency response to controls and is stated to have issues with accurate control (Le et al. 2016). The final actuator type reviewed uses a magnetic system which is capable of transferring motion wirelessly, however hysteresis and linearity issues do occur (Le et al. 2016). Therefore, it is not clear what the most recommended system to utilize is when producing a tele-operated surgical robotic system as each transmission method has various advantages and disadvantages associated to them. It is recommended that further research should be conducted to overcome or alleviate the disadvantages of the selected system (Le et al. 2016). Despite the amount of research studied in this area, it is important to note that these types of grippers are designed to handle biological material that are relatively large compared to microscale objects as discussed in previous chapters. For example, the smallest diameter of a human arteries is around 100 µm, which is stated as the maximum limit of microscale objects.

3.4 Magnetic guiding systems

Another method of object manipulation involves the use of a magnetic field to guide non-magnetic flexible wire by attaching a magnetic tip to the wire’s end. This method has been recently studied for use in the medical industry where minimally invasive surgery is become ever more researched. The method is used to accurately position a wire whilst inside of a patient. One paper studied into externally manipulating a wire whilst inside of a patient’s veins (Yeow et al. 2016). The system developed can adjust the angle of the flexible wire by using a robotically controlled magnetic field. As the flexible wire itself was non-magnetic, the tip of the wire was coated in a ferro-magnetic material and hence could be controlled by the magnetic field (Yeow et al. 2016). The magnetic field itself was produced by applying a current to several electromagnetic coils distributed around the manipulation zone (Yeow et al. 2016). The magnetic tip of the wire was able to be adjusted by altering the voltage applied to the coils (Yeow et al. 2016). The system was tested by measuring the deflection of the wire tip and comparing it to the input movement expected (Yeow et al. 2016). The measured deflection angle was found to be 20°, resulting in a deflection displacement of around 7 mm. One of the limitations with the system was that the size of the manipulation zone and the deflection angle were both limited by the applied magnetic field. It was stated that the flux density of their system was 20 mT, whereas other researchers used values around 100 mT (Yeow et al. 2016). By increasing the magnetic flux density, they would be able to increase the size of the work zone and the deflection of the wire (Yeow et al. 2016). This method is capable of adjusting the position of a wire on a fine scale. This type of system has the potential to be utilized in order to manipulate certain micro-objects e.g. wires. However, this research paper does not state the precision of the system and therefore may not be accurate enough to be able to manipulate micro-objects to a desired location as indicated. Another area of the medical industry where this form of technology has been researched for is related to the internal delivery of drugs to a specific location inside of a patients’ body (Shen et al. 2015). The research developed an electromagnetic field which was used to alter the position and alignment of microcapsules which contained both the drug required, but also iron particles which enabled the capsule to be positioned by the magnetic field (Shen et al. 2015). The electromagnetic field was created by using a system containing Helmoholz and Maxwell coil pairs which produce a uniform and gradient magnetic field respectively. This system successfully enabled to position the magnetic particles (Shen et al. 2015). The design of the drug delivery system had approximately a 21 mm3 manipulation zone due to the size of the coils, this system design could become unsuitable if larger components are required to be manipulated (Shen et al. 2015). The use of permanent magnets as a guiding system has also been researched for the medical industry (Schiemann et al. 2004). A guiding zone was reported by placing two magnets parallel to each other and on either side of the patient and were capable of producing a 0.1 T magnetic field (Schiemann et al. 2004). The magnets were able to be rotated and re-positioned to orientate the magnetic tip of the flexible wire. The tip of the wire comprised of a neodymium iron boron magnet due to its highly magnetic properties (Schiemann et al. 2004). The magnetic system was successfully able to rotate the tip of the wire in any direction. Although the angle of the tip was controlled using non-contact external magnetic fields, the progression of the wire into the patient is carried out manually. The magnetic field rotated the tip of the wire by an angle of 90° and it was calculated that a force of 0.56 g would be applied by the tip onto the internal walls of the patient (Schiemann et al. 2004). The paper concluded that the developed system was capable of accurate positioning of the magnetic tip of the wire whilst inside of an artificial test chambers, however the accuracy of the positioning of the tip was not specified. A complex system comprised of a series of eight electromagnets has also been developed (Kummer et al. 2010). The configuration of the system was capable of producing a non-uniform magnetic field throughout the manipulation zone (Kummer et al. 2010). The system, named OctoMag, was designed to control microrobots inside of a patient, whilst also to be used to manipulate a magnetic tipped wire, similar to the systems presented previously in this section. It is capable of manipulating an isolated microrobot by five degrees of freedom, not only its orientation, but also its position within the manipulation zone (Kummer et al. 2010). It utilizes a vision system as a form of feedback, to monitor the accurate location and orientation of the magnetic object. It was stated in the report that the Octomag system had the potential to be reduced in size and could be used for micromanipulation under a microscope (Kummer et al. 2010). During experimentation conducted with the microrobots it was said stated that a variation of 29.77 µm was present. Another successful magnetic navigation system has been described in Chun et al. (2007). The system includes two permanent magnets situated on either side of the patient. The magnets were able to create a 0.08 T uniform field across the patient and steer a tethered wire with a magnetised tip through the body (Chun et al. 2007). In the paper, it stated that different tip structures were trialled which included various number of magnets along the tip. It was concluded that the constructed tip which comprised of four magnets was the most controllable tether and therefore the most successful during tests (Chun et al. 2007).

3.5 Probe technology

The use of probe structures has also been studied to manipulation micro-objects. Many different technologies have been studied such as optical, mechanical, magnetic and electrostatic (Kawamoto 2009). The method of using an electrostatic force for manipulation has been successfully achieved by many researchers and is often intended for the manipulation of micro-particles such as biological cells and micro-mechanical and micro-electronic objects. One report concluded that tools for micromanipulation such as probes are preferred due to their simple design, whilst microgrippers involve a more complex design and are often delicate and expensive (Power and Yang 2015). Electrostatic probes are often capable of adhering to particles between the sizes of 10 µm to 1 mm (Kawamoto 2009; Takahashi et al. 2001). It has been stated that use of the probes are often limited to the manipulation of small spheres within this size as the adhesion forces, including van der Waals, electrostatic and liquid bridge forces are often larger than the gravitational forces that oppose them (Konno et al. 2005; Masuda et al. 2006; Saito et al. 2003). It is less common to be able to attract larger metallic micro objects as the electrostatic attraction is often weaker than the gravitational forces applied to it (Konno et al. 2005). It is stated that these adhesion forces occur between, the substrate and the particle and also the probe and the particle (Konno et al. 2005; Masuda et al. 2006). To ensure that the probe is capable of picking up the particle, the adhesion force between particle and probe must be larger than the sum of adhesion forces between substrate and particle and the gravitational force applied to the particle (Konno et al. 2005). These forces are affected by the materials and shape of the probe, particle and substrate (Konno et al. 2005). The force between the probe and the particle is enhanced by applying a voltage to the probe which increases the electrostatic force available (Konno et al. 2005). It is this force that ensures that the particle can be manipulated by the probe. The fabrication of the probes is typically manufactured from tungsten wire with a diameter of approximately 100 µm. The wire is often polished and coated in an insulating material to avoid the probe from short circuiting. Researchers have stated that the fabrication and operation of the probe is simple (Kawamoto and Tsuji 2011). Many configurations of probes have been developed and often consist of one, two or three metallic cores where a voltage is applied to. From this, a non-uniform electrostatic field is formed around the probe and generates a Coulomb force that is capable of attracting both non-conductive and conductive micro-particles towards it (Kawamoto 2009). It was established that for conductive micro-particles, the resistivity of the micro-particle material must be between 107 and 109 Ω cm while the voltage of the probe was 10 V (Kawamoto 2009). The probe is capable of releasing non-conductive particles by setting the voltage to zero (Kawamoto 2009). The same cannot be done for conductive particles as even after the voltage has reached zero the Coulomb adhesion force will still be present and will continue to attract the particle to the probe tip (Kawamoto 2009). The researchers investigated different elements of the probe and the particle to study what would influence the attraction forces of both. Such elements were the dimensions and voltage of the probe and dimensions and material of the micro-object. Even though that increasing the voltage increased the attraction forces, the voltage limit must be noted due to the insulated breakdown properties of the probe (Kawamoto 2009). The research results demonstrated that the duel-core probe, was capable of picking up non-conductive micro-particles with diameters of 150–2000 µm and a weight of about 1–1000 µg (Kawamoto 2009). Another configuration of probe, with a duel-core and a staggered tip, was capable of manipulating similar sized particles, with diameters of 100–1000 µm and a weight of 0.6–800 µg (Kawamoto 2009). The single tip probe configuration, which was coated in a gold layer was able to move much smaller particles, with diameters of 30–500 µm and a weight of 0.01–50 µg (Kawamoto 2009). The same researcher later demonstrated that the developed probe was able to pick up slightly conductive, non-spherical, lunar dust particles (Kawamoto and Tsuji 2011). The system was similar, if not identical to the probe developed in Kawamoto (2009). Another researcher carried out a similar electrostatic tip fabrication, but instead of using a tungsten wire they simply used a cantilever from an atomic force microscope due to it being an appropriate and repeatable shape and size (Denisyuk et al. 2014). This ensures that the experiment will be repeatable in the future. The experimentation of the cantilever probe was carried out on three different types of particles (Denisyuk et al. 2014). The particles were a mixture of spherical and octahedron in shape. During experimentation, it was noticed that the octahedron shaped particles could only be picked up while the probe was in contact with one of its vertices (Denisyuk et al. 2014). The researchers also produced a theoretical model of the manipulation of one of the particles. Using the model, they calculated that the probe was capable of attracting a particle while the distance between the probe tip and the particle was smaller than the diameter of the particle (Denisyuk et al. 2014). Another research that was conducted by previously was capable of manipulating 40–80 µm diameter gold spheres using a fine probe (Konno et al. 2005). This was accomplished by applying a 20–50 DC voltage to the probe (Konno et al. 2005). The spheres were then released by changing the voltage to zero. The researchers proved that their probe and system was capable of picking up the particle and also welding it to an additional particle by significantly increasing the voltage (Konno et al. 2005). As stated before, it was demonstrated that their developed probes were capable of manipulating micro-particles with a mass between 0.01 and 1000 µg (Kawamoto 2009). The mass of the wire is within the stated values which implies that this method would be capable of manipulating a variety of wire materials and sizes.

4 Summary

The aim of this review was to research an array of previously designed and developed micromanipulation tools and discuss the most suitable technology in order to manipulate specific objects required for the assembly of µ-wire. Robotic controlled micromanipulation tools such as previously mentioned microgrippers could be also be employed in order to achieve the high level of accuracy and repeatability required for assembly at this scale. The review has compared different micromanipulation tools currently available in order to manipulate micro-objects and specifies the most preferable solutions. A large variety of different micromanipulation techniques involving contact and contactless technologies have been summarised and evaluated. The majority of this review has focused on microgripper technologies, comparing the advantages and disadvantages of both their structure and actuator types as these are the fundamental components of determining the most suitable design for micromanipulation. After analysing, it became clear that high precision and repeatability were the most desirable characteristics of the manipulation tool. Robotic tools developed for the medical industry contain state-of-the-art technology, however they may not be suitable for this specific micromanipulation task due to the comparatively large scale of the objects that they are intended to grasp. Another manipulation technology studied utilized magnetic fields in order to orientate magnetic or magnetic-tipped wires (Power and Yang 2015). This form of technology is useful for guiding a wire through an intended path, although the system itself could not change the position of the object and only align it with the magnetic field, therefore would not be suitable for positioning certain µ-wire materials. Various technologies of probes were also studied, such as electrostatic; however, the system researched were only studied to have manipulated micro-objects that were near spherical in shape. The shape wire makes it more difficult to manipulate whilst using these technologies.

5 Conclusion

From the previously stated various microgripper actuator types, shape memory alloys actuated microgrippers previously developed have displayed large jaw displacement and high gripping force compared to other types (Kyung et al. 2008). The presented disadvantages such as high hysteresis error, large energy usage and a slow response time were agreed to not greatly impact the manipulation process of the given task (Yang et al. 2017). It seemed that this technology was the most suitable to manipulate µ-wire. The reviewed literature failed to include a suitable microgripper design that would be capable of grasping and positioning a micro-sized object such as µ-wire and larger sized objects. It is deemed that a solution to this problem must be addressed. Additionally, many microgrippers are found to be inaccurate, often due to the fabrication process which cause an undesired asymmetrical structure of microgripper (Liang et al. 2018). A solution to this issue has been previously presented while utilizing piezoelectric materials as a form of actuator (Liang et al. 2018), however, alternative actuation methods are being researched and there is potential for these to achieve a higher increase in grasp accuracy when used with specific microgripper designs. The microgripper design will need to ensure that a large range of objects can be grasped ranging from sizes of the µ-wire to different components such as PCBs. The developed microgripper must be versatile enough to assist with the manipulation of other micro-objects including those in other alternative industrial sectors.