Right ventricular volume unloading evaluated by tangential magnetocardiography

  • Original Article
  • Published:
The Japanese Journal of Thoracic and Cardiovascular Surgery Aims and scope Submit manuscript

Abstract

Objective: The evaluation of right ventricular volume overload in the presence of a right bundle branch block based solely on the results of an electrocardiogram is difficult. The purpose of this study was to purify acute right ventricular volume unloading from the tangential magnetocardiography.Methods: We measured the tangential (x-y plane) magnetocardiogram and electrocardiogram simultaneously in nine patients with a secundum atrial septal defect. The magnetocardiograms were obtained before surgical closure and during the immediate postoperative period using the 32-channel superconducting quantum interference device system in a magnetically shielded room.Results: The QRS duration on the surface electrocardiogram decreased significantly (p < 0.05) in the immediate postoperative period. The right ventricular depolarization time as measured by the magnetocardiogram was shortened from 40.3±6.1 to 25.3±7.4 milliseconds (p < 0.0005). The maximum peak amplitude during right ventricular depolarization decreased from 17.9±4.8 to 11.1±4.9 pT (p < 0.01).Conclusions: We conclude that acute volume unloading of the right ventricle was indicated quantitatively by shortening of the right ventricular depolarization time and a reduction in the amplitude of current vectors originating from the right ventricular depolarization on the tangential magnetocardiography.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Cohen D, Edelsack EA, Zimmerman JE. Magnetocardiograms taken inside a shield room with a superconducting point-contact magnetometer. Appl Phys Lett 1970; 16: 278–80.

    Article  Google Scholar 

  2. Cohen D, Hosaka H. Magnetic field produced by a current dipole. J Electrocardiol 1976; 9: 409–15.

    Article  PubMed  CAS  Google Scholar 

  3. Tsukada K, Haruta Y, Adachi A, et al. Multichannel SQUID system detecting tangential components of the cardiac magnetic field. Rev Sci Instrum 1995; 66: 5085–91.

    Article  CAS  Google Scholar 

  4. Gatzoulis MA, Till JA, Somerville J, et al. Mechanoelectrical interaction in tetralogy of Fallot. QRS prolongation relates to right ventricular size and predicts malignant ventricular arrhythmias and sudden death. Circulation 1995; 92: 231–7.

    PubMed  CAS  Google Scholar 

  5. Gatzoulis MA, Redington AN, Somerville J, et al. Should atrial septal defects in adults be closed? Ann Thorac Surg 1996; 61: 657–9.

    Article  PubMed  CAS  Google Scholar 

  6. Saarinen M, Karp PJ, Katila TE, Siltanen P. The magnetocardiogram in cardiac disorders. Cardiovasc Res 1974; 8: 820–34.

    Article  PubMed  CAS  Google Scholar 

  7. Moshage W, Achenbach S, Weikl A, Gohl A, Abrahamfuches K, Schneider S, et al. Progress in biomagnetic imaging of heart arrhythmias. Frontiers in European Radiology 1991; 18: 1–19.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Terada, Y., Mitsui, T., Sato, M. et al. Right ventricular volume unloading evaluated by tangential magnetocardiography. Jpn J Thorac Caridovasc Surg 48, 16–23 (2000). https://doi.org/10.1007/BF03218080

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF03218080

Index words

Navigation