In-vivo dosimetry from total body irradiation patients (2000–2006): results and analysis

  • Scientific Note
  • Published:
Australasian Physics & Engineering Sciences in Medicine Aims and scope Submit manuscript

Abstract

In-vivo dosimetry is an important technique to ensure accuracy of delivered dose during total body irradiation (TBI). We present an analysis of semiconductor diode dosimetry, constituting seven years of dosimetry data from eighty-six patients who underwent total body irradiation. For lateral field irradiation, the mean exit dose, averaged over five anatomical sites (head, sternal notch, chest, abdomen and pelvis) and as a percentage of the planned dose was 95.7 % (SD 7.8 %). For AP/PA irradiation, the mean exit dose averaged over five anatomical sites and as a percentage of the planned dose was 95.5 % (SD 9.8 %). We propose a number of possible reasons for these differences, including patient setup variations, movement of the patient and diodes during treatment, imprecise placement of planned bolus material, inaccurate inhomogeneity corrections and modelling by the treatment planning system.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Metcalfe, P., Kron, T. and Hoban,P.,The Physics of Radiotherapy X-rays from Linear Accelerators. Medical Physics Publishing Corporation, 1997.

  2. Planskoy, B., Tapper, P., Bedford, A. and Davis, F.,Physical aspects of total-body irradiation at the Middlesex Hospital (UCL group of hospitals), London 1988-1993: II. In vivo planning and dosimetry. Phys. Med. Biol. 41:2327–2343, 1996.

    Article  CAS  PubMed  Google Scholar 

  3. Mangili, P., Fiorino, C., Rosso, A., Cattaneo, G.M., Parisi, R., Villa, E. and Calandrino, R.,In vivo dosimetry by diode semiconductors in combination with portal films during TBI: reporting a 5-year clinical experience. Radiother. Oncol. 52:269–276, 1999.

    Article  CAS  PubMed  Google Scholar 

  4. Ribas, M., Jornet, N., Eudaldo, T., Carabante, D., Duch, M.A., Ginjaume, M., Gomez de Segura G. and Sanchez-Doblado, F.,Midplane dose determination during total body irradiation using in vivo dosimetry. Radiother. Oncol. 335:91–98, 1998.

    Article  Google Scholar 

  5. Briot, E., Dutreix, A. and Bridier, A.,Dosimetry for total body irradiation. Radiother. Oncol. 18 Suppl. 1:16–29, 1990.

    Article  Google Scholar 

  6. Hoogenhout, J., Brouwer, W.F., van Gasteren, J.J., Schattenberg, A., de Witte, T., van Daal, W.A. and Haanen, C.A.,Clinical and physical aspects of total body irradiation for bone marrow transplantation in Nijmegen. Radiother. Oncol. 18 Suppl. 1:118–120, 1990.

    Article  Google Scholar 

  7. Vrtar, M. and Kovacevic, N.,A model of in vivo dosimetry and quality assurance analysis of total body irradiation in Zagreb. Acta Med Croatica. 52(1):15–26, 1998.

    CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to C. M. Lancaster.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lancaster, C.M., Crosbie, J.C. & Davis, S.R. In-vivo dosimetry from total body irradiation patients (2000–2006): results and analysis. Australas. Phys. Eng. Sci. Med. 31, 191–195 (2008). https://doi.org/10.1007/BF03179343

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF03179343

Key words

Navigation