Abstract
Beta irradiation has recently been investigated as a possible technique for the prevention of restenosis in intravascular brachytherapy after balloon dilatation or stent implantation. Present methods of beta radiation dosimetry are primarily conducted using radiochromic film. These film dosimeters exhibit limited sensitivity and their characteristics differ from those of tissue, therefore the dose measurement readings require correction factors to be applied. In this work a novel, mini-size (2 mm diameter by 5 mm long) dosimeter element fabricated from Organic Plastic Scintillator (OPS) material was employed. Scintillation photon detection is accomplished using a precision photodiode and innovative signal amplification and processing techniques, rather than traditional photomultiplier tube methods. A significant improvement in signal to noise ratio, dynamic range and stability is achieved using this set-up. In addition, use of the non-saturating organic plastic scintillator material as the detector enables the dosimeter to measure beta radiation at very close distances to the source. In this work the plastic scintillators have been used to measure beta radiation dose at distances of less than 1 mm from an Sr-90 cardiovascular brachytherapy source having an activity of about 2.1 GBq beta radiation levels for both depth-distance and longitudinal profile of the source pellet chain, both in air and in liquid water, are measured using this system. The data obtained is compared with results from Monte Carlo simulation technique (MCNP 4B). Plastic scintillator dosimeter elements, when used in conjunction with photodiode detectors may prove to be useful dosimeters for cardiovascular brachytherapy beta sources, or other applications where precise near-source field dosimetry is required. The system described is particularly useful where measurement of actual dose rate in real time, a high level of stability and repeatability, portability, and immediate access to results are prime requirements.
Similar content being viewed by others
References
Suntharalingam, M., et al.,Clinical and angiographic outcomes after use of Sr-90/Y-90 beta radiation for the treatment of in-stent restenosis: results from the stents and radiation therapy 40 (START 40) registry, Int. J. Radiation Oncol. Biol. Phys. 52: 1075, 2002.
Popowski, Y., et al.,High dose rate brachytherapy for prevention of restenosis after percutaneous transluminal coronary angioplasty: Preliminary dosimetric test of a new source presentation, Int. J. Radiation Oncology Biol. Phys., 33(1): 211–215, 1995.
Fox, R.A.,Intravascular brachytherapy of the coronary arteries, Phys. Med. Biol., 47:R1-R30, (February 2002).
AAPM report Task Group No. 60,Intravascular brachytherapy physics, Med. Phys. 26(2): 119–152, February 1999.
Soares, C.G., Halpern, D.G. and Wang, C.K.,Calibration and characterisation of beta-particles sources for intravascular brachytherapy, Med. Phys. 25(3): 339–346, March 1988.
Soares, C.G.,Consistency standards for source strength of beta-particle sources, Vascular Radiotherapy Monitor, 3(3): 59–63, 2001.
Wang, R. and Li, X.A.,A Monte Carlo calculation of dosimetric parameters of Sr90/90Y and 192Ir SS sources for intravascular brachytherapy, Med. Phys. 27(11): 2528–2535, November 2000.
Wang, R. and Li, X.A.,Monte Carlo dose calculations of beta-emitting sources for intravascular brachytherapy: A comparison between EGS4, EGSnrc and MNCP, Med. Phys., 28(2): 134–141, February 2001.
Piessens, M. and Reynaert, N.,Verification of absolute dose rates for intravascular brachytherapy beta sources, Phys. Med. Biol., 45: 2219–2231, 2000.
Beddar, A.S.,A new Scintillator detector system for the quality assurance of Cobalt and high-energy therapy machines, Phys. Med. Biol., 39: 253–263, 1994.
Clift, M.A., Sutton, R.A. and Webb, D.V.,Water equivalence of plastic scintillators in megavoltage radiotherapy bremsstrahlung beams, Phys. Med. Biol., 45: 1885–1895, 2000.
Bambynek, M., Flühs, D, and Quast, U.,A high-precision, high-resolution and fast dosimetry system for beta sources applied in cardiovascular brachytherapy, Med. Phys., 27(4): 662–667, April 2000.
Attix, F. H.,Introduction to Radiological Physics and Radiation Dosimetry, John Wiley and Sons, 450–457, 1986.
Sehgal, V., Li, Z. and Palta, J.R.,Dosimetric effect of source centring and residual plaque for β-emitting catheter based intravascular brachytherapy sources, Med. Phys., 28(10): 2162–2171, October 2001.
Kotler, L., Private communication, ARPANSA, Yallambie Vic. Australia., September 2002.
Wallace, S.A., Schumer, W., and Horrigan, M.,Monte Carlo dosimetry of tandem positioned B emitting intravascular brachytherapy source train, Med. Phys., 26(4), April 2002.
Amin, M.N., Bonnett, D.E., and Harding, P.F.,A comparison of polyacrylamide gels and radiochromic film for source measurements in intravascular brachytherapy, British Journal of Radiology, 76: 824–831, 2003.
Beddar, A.S., et al.,Plastic scintillation dosimetry: optimisation of light collection efficiency, Phys. Med. Biol., 48: 1141–1152, 2003.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Geso, M., Robinson, N., Schumer, W. et al. Use of water-equivalent plastic scintillator for intravascular brachytherapy dosimetry. Australas. Phys. Eng. Sci. Med. 27, 5–10 (2004). https://doi.org/10.1007/BF03178881
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF03178881