A simplified approach for exit dose in vivo measurements in radiotherapy and its clinical application

  • Published:
Australasian Physics & Engineering Sciences in Medicine Aims and scope Submit manuscript

Abstract

This is a study using LiF:Mg;Ti thermoluminescent dosimeter (TLD) rods in phantoms to investigate the effect of lack of backscatter on exit dose. Comparing the measured dose with anticipated dose calculated using tissue maximum ratio (TMR) or percentage depth dose (PDD) gives rise to a correction factor. This correction factor may be applied to in-vivo dosimetry results to derive true dose to a point within the patient. Measurements in a specially designed humanoid breast phantom as well as patients undergoing radiotherapy treatment were also been done. TLDs with reproducibility of within ±3% (1 SD) are irradiated in a series of measurements for 6 and 10 MV photon beams from a medical linear accelerator. The measured exit doses for the different phantom thickness for 6 MV beams are found to be lowered by 10. 9 to 14. 0% compared to the dose derived from theoretical estimation (normalized dose at dmax). The same measurements for 10 MV beams are lowered by 9. 0 to 13. 5%. The variations of measured exit dose for different field sizes are found to be within 2. 5%. The exit doses with added backscatter material from 2 mm up to 15 cm, shows gradual increase and the saturated values agreed within 1. 5% with the expected results for both beams. The measured exit doses in humanoid breast phantom as well as in the clinical trial on patients undergoing radiotherapy also agreed with the predicted results based on phantom measurements. The authors’ viewpoint is that this technique provides sufficient information to design exit surface bolus to restore build down effect in cases where part of the exit surface is being considered as a target volume. It indicates that the technique could be translated forin vivo dose measurements, which may be a conspicuous step of quality assurance in clinical practice.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Leunens, G., Van Dam, J., Dutriex, A. and VanDer Schuren, E.,Quality assurance in radiotherapy by in vivo dosimetry. 2. Determination of the target absorbed dose. Radiother. Oncol. 19, 73–87. 1990.

    Article  CAS  PubMed  Google Scholar 

  2. Ferguson, H. M., Lambert, G. D. and Harrison, R. M.,Automated TLD System for tumour dose estimation from exit dose measurements in external beam radiotherapy. Int. J. Radiation Oncology Biol. Phys. 38, 899–905. 1997.

    Article  CAS  Google Scholar 

  3. Essers, M. and Mijnheer, B. J., In vivo dosimetry during external photon beam radiotherapy. Int. J. Radiation Oncology Biol. Phys. 43, 245–259. 1999.

    CAS  Google Scholar 

  4. Kron, T.,Thermoluminescence dosimetry and its applications in medicine. Part 2: History and applications. Australian Physical and Engineering Science in Medicine 18, 1–25. 1995.

    CAS  Google Scholar 

  5. Purdy, J. A.Build-up/surface dose and exit dose measurements for a 6 MV linear accelerator. Med. Phys. 13, 259–262. 1986.

    Article  CAS  PubMed  Google Scholar 

  6. Kron, T. and Ostwald, P.Skin exit dose in megavoltage x-ray beams determined by means of a plane parallel ionization chamber (Attix chamber), Med. Phys., 22, 577–578. 1995.

    Article  CAS  PubMed  Google Scholar 

  7. Kron, T. Elliot, A. Wong, T. Showell, G. Clubb, B. and Metcalfe, P.X-ray surface dose measurements using TLD extrapolation, Med. Phys., 20, 703–711. 1993.

    Article  CAS  PubMed  Google Scholar 

  8. Kron, T, Butson, M., Hunt, F., Denham, J.TLD extrapolation for skin dose determination in vivo. Radiotherapy and Oncology 41, 119–123. 1996.

    Article  CAS  PubMed  Google Scholar 

  9. Stasi, M., Borca, V. C., Fiorino, C.Measurements of exit dose profiles in 60 Co beams with a conventional portal film system. British Journal of Radiology, 70, 1283–1287. 1997.

    CAS  PubMed  Google Scholar 

  10. Heukelom, S., Lanson, J. H. and Mijnheer, B. J.Comparison of entrance and exit dose measurements using ionization chambers and silicon diodes. Phys. Med. Biol. 36, 47–59. 1991.

    Article  CAS  PubMed  Google Scholar 

  11. Leunens, G., Van Dam, J., Dutriex, A. and VanDer Schuren, E.Importance of in vivo dosimetry as part of a quality assurance program in tangential breast treatments. Int. J. Radiation Oncology Biol. Phys. 28, 285–296. 1994.

    CAS  Google Scholar 

  12. Loncol, Th., Greffe, J. L., Vynckier, S., Scalliet, P.Entrance and exit dose measurements with semiconductors and thermoluminescent dosimeters: a comparison of methods and in vivo results. Radiother. Oncol. 41, 179–187. 1996.

    Article  CAS  PubMed  Google Scholar 

  13. Millwater, C. J., Macleod, A. S., Thwaites, D. I. In vivo semiconductor dosimetry as part of routine quality assurance. British Journal of Radiology, 71, 661–668. 1998.

    CAS  PubMed  Google Scholar 

  14. Boellaard, R., Essers, M., Herk, V. M., Mijnheer, B. J.New method to obtain the midplane dose using portal in vivo dosimetry. Int. J. Radiation Oncology Biol. Phys. 41, 465–474. 1998.

    CAS  Google Scholar 

  15. Weltens, C., Huyskens, D., Dutreix, A., Schueren, E.Assesment of dose inhomogeneities in clinical practice by film dosimetry. Radiother. Oncol. 49, 287–294. 1998.

    Article  CAS  PubMed  Google Scholar 

  16. Van Dan, J. and Marinello, G.Methods for in vivo dosimetry in external radiotherapy. ESTRO booklet No. 1. 1994.

  17. National Breast Cancer Center (NBCC),Survey of practice on post mastectomy radiotherapy — in Radiotherapy and Breast Cancer. National Library of Australia Cataloguing-inpublication data. 1999.

  18. Furetta, C and Weng, P. S.Operational Thermoluminescence Dosimetry. World Scientific, Singapore. 1998.

    Google Scholar 

  19. . Horowitz, Y. S.The annealing characteristics of LiF: Mg, Ti. Radiation Protection dosimetry 30, 219–230. 1990.

    CAS  Google Scholar 

  20. Banjade, D. P., Tajuddin, A. A., and Shukri, A.Determination of absorbed dose from photon and electron beams from a linear accelerator comparing different protocols in different phantoms. Applied Radiation and Isotopes 55, 235–243. 2001.

    Article  CAS  PubMed  Google Scholar 

  21. AAPM (American Association of Physicists in Medicine), TG-21,A protocol for the determination of absorbed dose from high-energy photon and electron beams. Med. Phys. 10,741–7711. 1983.

    Article  Google Scholar 

  22. McKinley, A. F.Thermoluminescence Dosimetry. (Medical Physics Handbook 5). Adam Hilger Ltd. In collaboration with Hospital Physicists’ Association, UK. 1981.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to D. P. Banjade.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Banjade, D.P., Shrestha, S.L., Shukri, A. et al. A simplified approach for exit dose in vivo measurements in radiotherapy and its clinical application. Australas. Phys. Eng. Sci. Med. 25, 110–118 (2002). https://doi.org/10.1007/BF03178771

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF03178771

Key words

Navigation