Abstract
This paper describes the process and results of a survey of linear accelerator outputs as part of an Australasian Level III Dosimetry Intercomparison. This study involved the measurement of accelerator output under reference conditions (‘Level I’) with a small-volume ionisation chamber in water for 47 beams at 36 radiotherapy centres using the IAEA TRS 398 dose-to-water protocol. The mean ratio of measured to locally-determined accelerator output was 1.003±0.009 (1 standard deviation) with a range from 0.981 to 1.024. No correlation could be found between output ratio and accelerator type or local output calibration protocol. The small-volume chamber used satisfied most requirements for the study though showed some variation in sensitivity via repeated cross-calibration with a chamber calibrated at a primary standards laboratory.
Similar content being viewed by others
References
Kron, T., Hamilton, C., Roff, M. and Denham, J.,Dosimetric intercomparison for two Australasian clinical trials using an anthropomorphic phantom, Int J Radiat Oncol Biol Phys, 52(2): 566–79, 2002.
Izewska, J., Georg, D., Bera, P., Thwaites, D., Arib, M., Saravi, M., Sergieva, K., Li, K., Yip, F.G., Mahant, A.K. and Bulski, W.,A methodology for TLD postal dosimetry audit of high-energy radiotherapy photon beams in non-reference conditions, Radiother Oncol, 84(1): 67–74, 2007.
IAEA,Lessons learned from accidental exposures in radiotherapy, International Atomic Energy Agency, Safety Report Series N17, Vienna.
Bentzen, S.M., Bernier, J., Davis, J.B., Horiot, J.C., Garavaglia, G., Chavaudra, J., Johansson, K.A. and Bolla, M.,Clinical impact of dosimetry quality assurance programmes assessed by radiobiological modelling of data from the thermoluminescent dosimetry study of the European Organization for Research and Treatment of Cancer, Eur J Cancer, 36(5): 615–20, 2000.
IAEA. IAEA TLDPostal Dose Audit Service. http://wwwnaweb. iaea.org/nahu/dmrp/tld.asp. 2007
Izewska, J., Andreo, P., Vatnitsky, S. and Shortt, K.R.,The IAEA/WHO TLD postal dose quality audits for radiotherapy: a perspective of dosimetry practices at hospitals in developing countries, Radiother Oncol, 69(1): 91–7, 2003.
Izewska, J., Bera, P. and Vatnitsky, S.,IAEA/WHO TLD postal dose audit service and high precision measurements for radiotherapy level dosimetry. International Atomic Energy Agency/World Health Organization, Rad Prot Dosim, 101(1–4): 387–92, 2002.
Izewska, J., Gajewski, R., Gwiazdowska, B., Kania, M. and Rostkowska, J.,TLD postal dose intercomparison for megavoltage units in Poland, Radiother Oncol, 36(2): 143–52, 1995.
Svensson, H., Hanson, G.P. and Zsdanszky, K.,The IAEA/WHO TL dosimetry service for radiotherapy centres 1969–87, Acta Oncologica, 29(4): 461–7, 1990.
Ferreira, I.H., Dutreix, A., Bridier, A., Chavaudra, J. and Svensson, H.,The ESTRO-QUALity assurance network (EQUAL), Radiother Oncol, 55(3): 273–84, 2000.
Hansson, U., Johansson, K.A., Horiot, J.C. and Bernier, J.,Mailed TL dosimetry programme for machine output check and clinical application in the EORTC radiotherapy group, Radiother Oncol, 29(2): 85–90, 1993.
Roue, A., Van Dam, J., Dutreix, A. and Svensson, H.,[The EQUAL-ESTRO external quality control laboratory in France], Cancer Radiotherapie, 8 Suppl 1: S44–9, 2004.
Nisbet, A. and Thwaites, D.I.,A dosimetric intercomparison of electron beams in UK radiotherapy centres, Phys Med Biol, 42(12): 2393–409, 1997.
Nisbet, A., Thwaites, D.I. and Sheridan, M.E.,A dosimetric intercomparison of kilovoltage X-rays, megavoltage photons and electrons in the Republic of Ireland, Radiother Oncol, 48(1): 95–101, 1998.
Thwaites, D.I., Williams, J.R., Aird, E.G., Klevenhagen, S.C. and Williams, P.C.,A dosimetric intercomparison of megavoltage photon beams in UK radiotherapy centres, Phys Med Biol, 37(2): 445–61, 1992.
Venables, K.,The national trials QA centre. Who are we, what we do, and how we can help you, Scope, 15: 10–15, 2006.
Huntley, R. and Izewska, J.,The 1998 Australian external beam radiotherapy survey and IAEA/WHO TLD postal dose quality audit, Aust Phys Eng Sci Med, 23(1): 21–9, 2000.
Amies, C., Rose, A., Metcalfe, P. and Barton, M.,Multicentre dosimetry study of mantle treatment in Australia and New Zealand, Radiother Oncol, 40(2): 171–80, 1996.
Delaney, G., Beckham, W., Veness, M., Ahern, V., Back, M., Boyages, J., Fox, C., Graham, P., Jacob, G., Lonergan, D., Morgan, G., Pendlebury, S. and Yuile, P.,Three-dimensional dose distribution of tangential breast irradiation: results of a multicentre phantom dosimetry study, Radiother Oncol, 57(1): 61–8, 2000.
Kron, T., Barnes, K. and O’Brien, P.,Multicentre dosimetric comparison of photon-junctioning techniques in head and neck radiotherapy, Aust Radiol, 47(3): 289–94, 2003.
Cox, M., Huntley, R. and Webb, D.,A TLD therapy dosimetry quality assurance program for Australia — Results 2002–2003, Aust Phys Eng Sci Med, 27(4): 264–265, 2004.
IAEA,Absorbed dose determination in external beam radiotherapy: An international code of practice for dosimetry based on standards of absorbed dose to water, International Atomic Energy Agency, Technical Report Series No. 398, Vienna.
IAEA,Absorbed dose determination in photon and electron beams: An international code of practice, International Atomic Energy Agency, Technical Report Series No. 277, Vienna.
Ebert, M.A., Harrison, K., Cornes, D., Howlett, S., Joseph, D.J., Kron, T., Hamilton, C.S. and Denham, J.W.,A comprehensive Australasian multi-centre dosimetric intercomparison — issues, logistics and recommendations, Journal of Medical Imaging and Radiation Oncology, In press, 2008.
Ebert, M.A., Harrison, K., Denham, J.W., Cornes, D., Howlett, S. and Hamilton, C.,QA of conformal radiotherapy for multi-centre radiotherapy trials in Australasia, inInternational Conference on Quality Assurance and New Technologies in Radiation Medicine. 2006, IAEA: Vienna, Austria.
Followill, D.S., Tailor, R.C., Tello, V.M. and Hanson, W.F.,An empirical relationship for determining photon beam quality in TG-21 from a ratio of percentage depth doses, Medical Physics, 25: 1202–1205, 1998.
Castro, P., Garcia-Vicente, F., Minguez, C., Floriano, A., Sevillano, D., Pérez, L. and Torres, J.J.,Study of the uncertainty in the determination of the absorbed dose to water during external beam radiotherapy calibration, Journal of Applied Clinical Medical Physics, 9(1): 70–86, 2008.
Millar, M., Cramb, J., Das, R., Ackerly, T., Brown, G., Webb, D.,ACPSEM Position Paper Recommendations for the Safe Use of External Beams and Sealed Brachytherapy Sources in Radiation Oncology, Aust Phys Eng Sci Med, 20(3): 1–35, 1997.
Butler, D.J., Palmans, H. and Webb, D.V.,Shift in absorbed dose for megavoltage photons when changing to TRS-398 in Australia, Aust Phys Eng Sci Med, 28(3): 159–164, 2005.
Wittkämper, F.W., Mijnheer, B.J. and van Kleffens, H.J.,Dose intercomparison at the radiotherapy centres in The Netherlands. 1. Photon beams under reference conditions and for prostatic cancer treatment, Radiother Oncol, 9(1): 33–44, 1987.
Al-Mokhlef, J.M. and Noori, N.,Quality assurance study for dosimetry of radiation therapy equipment in Saudi Arabia, Annals Of Saudi Medicine, 23(3–4): 148–151, 2003.
Huntley, R.B. and Nette, H.P.,International Atomic Energy Agency/World Health Organisation TLD radiotherapy dosimetry intercomparison, Aust Phys Eng Sci Med, 16(1): 44–8, 1993.
Davis, B. and Faessler, P.,Quality audit of megavoltage radiotherapy units: intercomparison of dose at a reference point using a mailed TL-dosimetry system, Radiother Oncol, 28(1): 79–81, 1993.
Dutreix, A., Derreumaux, S., Chavaudra, J. and van der Schueren, E.,Quality control of radiotherapy centres in Europe: beam calibration, Radiother Oncol, 32(3): 256–264, 1994.
Schiefer, H., Seelentag, W. and Stucki, G.,Ein nationaler Dosimetrievergleich durch Postversand von TLDs. Swiss Society of Radiobiology and Medical Physics, 2001. http://www.sgsmp.ch/annrepA1.htm
Aguirre JF, T.R., Ibbott G, Stovall M, Hanson WF.Thermoluminscenence dosimetry as a tool for the remote verification of output for radiotherapy beams: 25 years of experience. inProceedings of an International Symposium on Standards and Codes of Practice in Medical Radiation Dosimetry. Proceedings of an International Symposium on Standards and Codes of Practice in Medical Radiation Dosimetry. Vienna: IAEA, 2002.
Kroutilíková, D., Novotný, J. and Judas, L.,Thermoluminescent dosimeters (TLD) quality assurance network in the Czech Republic, Radiother Oncol, 66(2): 235–244, 2003.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Ebert, M.A., Howlett, S.J., Harrison, K. et al. Linear-accelerator X-ray output: a multicentre chamber-based intercomparison study in Australia and New Zealand. Australas. Phys. Eng. Sci. Med. 31, 268–279 (2008). https://doi.org/10.1007/BF03178596
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF03178596