Abstract
Head scatter factors can be determined either experimentally or using published formulas. Two available formulas are the 4A/P method and a formalism presented by Vadash and Bjärngard1, of which the second accounts for collimator exchange effect. It was the aim of this study to compare the accuracy of these formulas in calculating head scatter factors for a Siemens Oncor linear accelerator. Head scatter factors were measured using a mini-phantom, and equivalent squares were then determined by fitting to the square field data. These were compared with calculated equivalent squares using the Vadash formalism, and a parameter was found that minimised differences between calculated and measured data. The Vadash and 4A/P formulae were then used to calculate head scatter factors for a range of field sizes, and compared relative to measured data. It was found that the Vadash formalism improved the accuracy of calculated head scatter factors by an average 0.5% for Siemens Primus and Oncor linear accelerators across all field sizes and energies, when compared with the 4A/P method.
Similar content being viewed by others
References
Vadash, P. and Bjärngard, B.,An equivalent-square formula for head scatter factors, Med. Phys, 20 (3):3733–734, 1993.
Day, M.J. and Aird, E.G.A.,The equivalent field method for dose determinations in rectangular fields. In British Journal of Radiology Supplement 25: Central Axis Depth Dose Data for Use in Radiotherapy, British Institute of Radiology, London, pp. 138–151, 1996.
Kim, S., Zhu, T.C. and Palta, J.R.,An equivalent square field formula for determining head scatter factors of rectangular fields, Med. Phys. 24 (11), 1770–1774, 1997.
Yu, M.K. and Sloboda, R., Analytical representation of head scatter factors for shaped photon beams using a twocomponent x-ray source model, Med. Phys, 23 (6), 973–984, 1996.
Yu, M.K., Murray, B. and Sloboda, R.,Parameterization of head scatter factors for rectangular photon fields using an equivalent square formalism, Med. Phys. 22 (8), 1329–1332, 1995.
Mijnheer, B., Bridier, A., Garibaldi, C., Tozsok, K. and Venselaar, J.,Monitor Unit Calculation for High Energy Photon Beams — Practical Examples, ESTRO Physics for Clinical Radiotherapy Booklet No. 6, ESTRO Brussels, Belgium, 2001.
Siemens Medical Systems, 3-D MLC and OPTIFOCUS Fully Integrated Multileaf Collimators_MIND_10706365_1.pdf,www.siemens.com.medical
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Norvill, C.A.J., White, P.A. An investigation of equivalent square formulas. Australas. Phys. Eng. Sci. Med. 31, 151–153 (2008). https://doi.org/10.1007/BF03178590
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF03178590