Abstract
EBT Gafchromic film, a new high sensitivity radiochromic film has been tested to evaluate if external pressure on the film can affect absorption spectra analysis and thus radiation dosimetry. This question arises from the fact that Gafchromic film is often cut into smaller pieces or to certain shapes for dosimetric analysis using scissors which can apply significant pressure to the sides of the film and small film pieces are placed within a solid phantom at depth which can produce significant pressure on the film if appropriate weight distribution procedures are not performed. As expected, results have shown that films cut by scissors can produce a large increase in OD near the film edge up to 5–10 mm away due to physical damage to the EBT film layers. Films placed within a solid phantom receiving up to 39.5 kg/cm2 pressure showed negligible differences in measured absorption spectra compared with control films subject to no external pressure. This equates to negligible external pressure effects for as much as 44 cm of 30 cm × 30 cm solid water placed on a 1 cm2 area film piece. As such, we recommend based on results herein, that film analysis should be performed with a boundary around every film edge, which can be defined visually based in the film. Also film dosimetry in a phantom can be performed with weights up to 39.5 kg/cm2 (or 44 cm of 30 cm × 30 cm solid water or equivalent) placed on the film without effecting the absorption spectra and thus dosimetry of radiation beams.
Similar content being viewed by others
References
Butson, M.J., Yu, K.N., Cheung, T., Metcalfe, P.E., “Radiochromic film for Medical Radiation Dosimetry”, Materials Science & Engineering R: Reports, 41, 61–120, 2003.
Butson, M.J., Cheung, T., Yu, K.N., “Radiochromic film: the new x-ray dosimetry and imaging tool”, Australasian Physical & Engineering Sciences in Medicine, 27, 230, 2004.
Cheung, T., Butson, M.J., Yu, K.N., “Multilayer Gafchromic film detectors for breast skin dose determinationin vivo”, Physics in Medicine and Biology, 47, N31–37, 2002.
Chiu-Tsao ST, Duckworth T, Zhang C, Patel NS, Hsiung CY, Wang L, Shih JA, Harrison LB.Dose response characteristics of new models of GAFCHROMIC films: dependence on densitometer light source and radiation energy. Med Phys. Sep;31(9):2501–8, 2004.
Mack A, Mack G, Weltz D, Scheib SG, Bottcher HD, Seifert V. High precision film dosimetry with GAFCHROMIC films for quality assurance especially when using small fields. Med Phys. 30(9):2399–409, 2003.
Butson, M.J., Cheung, T., Yu, K.N., “Spatial resolution of a stacked radiochromic film dosimeter”, 2001, Radiotherapy and Oncology, 61, 211–213, 2001.
Klassen N., Zwan L., Cygler J., Gafchromic MD-55: investigated as a precision dosimeter.Med phys 24 1924–1934, 1997.
Butson, M.J., Cheung, T., Yu, K.N., “XR type R radiochromic film x-ray energy response”, Physics in Medicine and Biology, 50, N195-N199, 2005.
Cheung, T., Butson, M.J., Yu, K.N., “Weak energy dependence of EBT Gafchromic film dose response in the 50 kVp-10 MVp X-ray range”, Applied Radiation and Isotopes, 64, 60–62, 2006.
Butson M, Yu P, Metcalfe P, Effects of readout light sources and ambient light on radiochromic film Phys Med Biol 43 2407–2412, 1998.
Niroomand-Rad A, Blackwell C, Coursey B, Gall K, Galvin J, McLaughlin W, Meigooni A, Nath R, Rodgers J, Soares C Radiochromic film dosimetry: Recommendation of AAPM radiation therapy task group 55.Med Phys 25 (11) 2093–2115, 1998.
ISP Corp web site, www.ispcorp.com, (2005).
Butson, M.J., Cheung, T., Yu, K.N., “Absorption spectra variations of EBT radiochromic film from radiation exposure”, Physics in Medicine and Biology, 50, N135-N140, 2005.
Butson, M.J., Yu, K.N., Cheung, T., Metcalfe, P., “High sensitivity radiochromic film dose comparisons”, Physics in Medicine and Biology, 47, N291-N295, 2002.
Cheung, T., Butson, M.J., Yu, K.N., “Post irradiation coloration of Gafchromic EBT radiochromic film”, Physics in Medicine and Biology, 50, N281-N285, 2005.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Yu, P.K.N., Butson, M. & Cheung, T. Does mechanical pressure on radiochromic film affect optical absorption and dosimetry?. Australas. Phys. Eng. Sci. Med. 29, 285–287 (2006). https://doi.org/10.1007/BF03178580
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF03178580