Scanning orientation effects on Gafchromic EBT film dosimetry

  • Technical Note
  • Published:
Australasian Physics & Engineering Sciences in Medicine Aims and scope Submit manuscript

Abstract

Gafchromic EBT film, a new high sensitivity radiochromic film has been tested for variations in optical properties due to scanning orientation. Gafchromic EBT film has been shown to produce a scanning orientation effect whereby variations in measured relative optical density are found due to the films orientation relative to the scanner direction. This relative optical density change was found to be relatively consistent for different films exposed to varying dose levels ranging from 0 Gy to 3 Gy. A maximum variation of 0.0157±0.0035 in optical density (OD) was found. This relates to an approximate 15 % variation in net OD for a 50 cGy irradiated film and 4 % variation for a 3 Gy irradiated film. No noticeable effects or variations were seen with changing scanning resolution or with the film placed “up or down” during scanning. Other Gafchromic film types were tested and compared to EBT for unirradiated film to assess the magnitude of this orientation effect on the scanner used and results showed that EBT produced a significantly higher effect that MD-55-2, HS, XR type T and XR type R film by up to 3 times. As such, providing the same orientation of EBT film when scanning for dosimetric analysis becomes an essential part of EBT film dosimetry.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Butson, M.J., Cheung, T. and Yu, K.N.Visible absorption properties of radiation exposed XR type T radiochromic film, Physics in Medicine and Biology, 49, N347–351, 2004.

    Article  PubMed  Google Scholar 

  2. Butson, M.J., Cheung, T. and Yu, K.N.XR type R radiochromic film x-ray energy response, Physics in Medicine and Biology, 50, N195-N199, 2005.

    Article  PubMed  Google Scholar 

  3. Cheung, T., Butson, M.J. and Yu, K.N.Reflection spectrometry analysis of irradiated GAFCHROMIC XR type R radiochromic films, Applied Radiation and Isotopes, 63, 127–129, 2005.

    Article  CAS  PubMed  Google Scholar 

  4. Dini, S.A., Koona, R.A., Ashburn, J.R. and Meigoonia, A.S.Dosimetric evaluation of GAFCHROMIC XR type T and XR type R films, J Appl Clin Med Phys. Winter; 6(1):114–34. Epub 2005 Jan 12, 2005.

    Article  PubMed  Google Scholar 

  5. Butson, M.J., Yu, K.N. and Metcalfe, P.E.Extrapolated surface dose measurements with radiochromic film, Medical Physics, 26, 485–488, 1999.

    Article  Google Scholar 

  6. Butson, M.J., Yu, K.N., Cheung, T. and Metcalfe, P.High sensitivity radiochromic film dose comparisons, Physics in Medicine and Biology, 47, N291-N295, 2002.

    Article  PubMed  Google Scholar 

  7. Butson, M.J., Cheung, T. and Yu, K.N.Radiochromic film: the new x-ray dosimetry and imaging tool, Australasian Physical & Engineering Sciences in Medicine, 27, 230, 2004.

    Article  Google Scholar 

  8. Cheung, T., Butson, M.J. and Yu, K.N.Multilayer Gafchromic film detectors for breast skin dose determination in vivo, Physics in Medicine and Biology, 47, N31–37, 2002.

    Article  PubMed  Google Scholar 

  9. Klassen, N., Zwan, L. and Cygler, J.Gafchromic MD-55: investigated as a precision dosimeter, Med phys 24 1924–1934, 1997.

    Article  CAS  PubMed  Google Scholar 

  10. Mack, A., Mack, G., Weltz, D., Scheib, S.G., Bottcher, H.D. and Seifert, V.High precision film dosimetry with GAFCHROMIC films for quality assurance especially when using small fields, Med Phys. Sep; 30(9):2399–409, 2003.

    Article  Google Scholar 

  11. Meigooni, A., Sanders, M., Ibbott, G. and Szeglin, S.Dosimetric characteristics of an improved radiochromic film Med. Phys.; 23:1883–1888, 1996.

    Article  CAS  PubMed  Google Scholar 

  12. Cheung, T., Yu, K.N. and Butson, M.J.Measurements of centi-Gray x-ray dose levels with radiochromic film, IEEE Transactions on Nuclear Science, accepted for publication, 2005.

  13. Butson, M.J., Cheung, T. and Yu, K.N.Absorption spectra variations of EBT radiochromic film from radiation exposure, Physics in Medicine and Biology, 50, N135-N140, 2005.

    Article  CAS  PubMed  Google Scholar 

  14. Rink, A., Vitkin, I. and Jaffray, D.Characterization and real-time optical measurements of the ionizing radiation dose response for a new radiochromic medium. Med Phys. Aug; 32(8):2510–6, 2005.

    Article  Google Scholar 

  15. Cheung, T., Butson, M.J. and Yu, K.N.Weak energy dependence of EBT Gafchromic film dose response in the 50 kVp — 10 MVp X-ray range, Applied Radiation and Isotopes, 64, 60–62, 2006.

    Article  PubMed  CAS  Google Scholar 

  16. Butson, M.J., Yu, K.N., Cheung, T. and Inwood, D.Polarization effects on a high sensitivity radiochromic film, Physics in Medicine and Biology, 48, N207–211, 2003.

    Article  PubMed  Google Scholar 

  17. Cheung, T., Butson, M.J. and Yu, K.N.Evaluation of a fluorescent light densitometer for radiochromic film analysis, Radiation Measurements, 35, 13–16, 2002.

    Article  CAS  Google Scholar 

  18. Chiu-Tsao, S.T., Duckworth, T., Zhang, C., Patel, N.S., Hsiung, C.Y., Wang, L., Shih, J.A. and Harrison, L.B.Dose response characteristics of new models of GAFCHROMIC films: dependence on densitometer light source and radiation energy, Med Phys. Sep; 31(9):2501–8, 2004.

    Article  CAS  Google Scholar 

  19. Gluckman, G.R. and Reinstein LE.Comparison of three high-resolution digitizers for radiochromic film dosimetry, Med Phys. Aug; 29(8):1839–46, 2002.

    Article  CAS  Google Scholar 

  20. ISP Corp web site, www.ispcorp.com, 2005.

  21. Butson, M., Yu, P. and Metcalfe, P.Effects of readout light sources and ambient light on radiochromic film, Phys Med Biol 43 2407–2412, 1998.

    Article  CAS  PubMed  Google Scholar 

  22. Butson, M.J., Yu, K.N., Cheung, T. and Metcalfe, P.E.Radiochromic film for Medical Radiation Dosimetry, Materials Science & Engineering R: Reports, 41, 61–120, 2003.

    Article  CAS  Google Scholar 

  23. Constanitinou, C., Attix, F. and Paliwal, B.A solid water phantom material for radiotherapy X-ray and gamma ray beam ray calculations, Med Phys. 9 436–441, 1982.

    Article  Google Scholar 

  24. Devic, S., Seuntjens, J., Sham, E., Podgorsak, E.B., Schmidtlein, C. R., Kirov, A. S. and Soares, C. G.Precise radiochromic film dosimetry using a flat-bed document scanner, Med Phys. Jul; 32(7):2245–53, 2005.

    Article  Google Scholar 

  25. Devic, S., Seuntjens, J., Hegyi, G., Podgorsak, E.B., Soares, C.G., Kirov, A.S., Ali, I., Williamson, J.F. and Elizondo, A.Dosimetric properties of improved GafChromic films for seven different digitizers, Med Phys. Sep; 31(9):2392–401, 2004.

    Article  CAS  Google Scholar 

  26. Niroomand-Rad, A., Blackwell, C., Coursey, B., Gall, K., Galvin, J., McLaughlin, W., Meigooni, A., Nath, R., Rodgers, J. and Soares, C.Radiochromic film dosimetry: Recommendation of AAPM radiation therapy task group 55, Med Phys 25 (11) 2093–2115, 1998.

    Article  CAS  PubMed  Google Scholar 

  27. Cheung, T., Butson, M.J., Yu, K.N.Post irradiation coloration of Gafchromic EBT radiochromic film, Physics in Medicine and Biology, 50, N281-N285, 2005.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to M. J. Butson.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Butson, M.J., Cheung, T. & Yu, P.K.N. Scanning orientation effects on Gafchromic EBT film dosimetry. Australas. Phys. Eng. Sci. Med. 29, 281–284 (2006). https://doi.org/10.1007/BF03178579

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF03178579

Key words

Navigation