Abstract
The effects of chamber polarity have been investigated for the measurement of 6MV and 18MV x-ray surface dose using a parallel plate ionization chamber. Results have shown that a significant difference in measured ionization is recorded between polarities at 6MV and 18MV at the phantom surface. A polarity ratio ranging from 1.062 to 1.005 is seen for 6MV x-rays at the phantom surface for field sizes 5cm × 5cm to 40cm × 40cm when comparing positive to negative polarity. These ratios range from 1.024 to 1.004 for 18MV x-rays with the same field sizes. When these charge reading are compared to the Dmax readings of the same polarity it is found that these polarity effects are minimal for the calculation of percentage dose results with variations being less than 1% of maximum.
Similar content being viewed by others
References
Fiorino, C., Mangili, P., Cattaneo, G. M., Calandrino, R.,Polarity effects of ionization chambers used in tbi dosimetry due to cable irradiation, Med Dosim. 25: 121–6, 2000.
Fiorino, C., Cattaneo, G. M., del Vecchio, A., Fusca, M., Longobardi, B., Signorotto, P., Calandrino, R.,Cable-induced effects on plane — parallel ionization chambe measurements in large clinical electron beams, Med Dosim 19: 73–4, 1994
Wickman, G., Holmstrom, T.,Polarity effect in plane-parallel ionization chambers using air or a dielectric liquid as ionization medium, Med Phys 19: 637–40, 1992.
Ramsey, C. R., Spencer, K. M., Oliver, A. L.,Ionization chamber, electrometer, linear accelerator, field size, and energy dependence of the polarity effect in electron dosimetry, Med Phys 26: 214–9, 1999.
Gerbi, B. J.,The response characteristics of a newly designed plane-parallel ionization chamber in high-energy photon and electron beams, Med Phys 20: 1411–5, 1993.
Rawlinson, J. A., Arlen, D., Newcombe, D.,Design of parallel plate ion chambers for build up measurements in megavoltage photon beams, Med Phys 19: 641–8, 1992.
Constantinou, C., Attix, F. H., Paliwal, B. R.,A solid water phantom material for radiotherapy X-ray and gamma ray beam ray calculations, Med. Phys. 9: 436–441 1982.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Butson, M.J., Yu, P.K.N. & Cheung, T. Polarity effect on surface dose measurement for an attix parallel plate ionisation chamber. Australas. Phys. Eng. Sci. Med. 26, 84–86 (2003). https://doi.org/10.1007/BF03178463
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF03178463