Extrapolated surface dose measurements using a NdFeB magnetic deflector for 6 MV x-ray beams

  • Technical Note
  • Published:
Australasian Physics & Engineering Sciences in Medicine Aims and scope Submit manuscript

Abstract

Extrapolated surface dose measurements have been performed using radiographic film to measure 2-Dimensional maps of skin and surface dose with and without a magnetic deflector device aimed at reducing surface dose. Experiments are also performed using an Attix parallel plate ionisation chamber for comparison to radiographic film extrapolation surface dose analysis. Extrapolated percentage surface dose assessments from radiographic film at the central axis of a 6 MV x-ray beam with magnetic deflector for field size 10 × 10 cm2, 15 × 15 cm2 and 20 × 20 cm2 are 9±3 %, 13±3 % and 16±3 %, these compared to 14±3 %, 19±3 %, and 27±3 % for open fields, respectively. Results from Attix chamber for the same field size are 12±1 %, 15±1 % and 18±1 %, these compared to 16±1 %, 21±1 % and 27±1 % for open fields, respectively. Results are also shown for profiles measured in-plane and cross-plane to the magnetic deflector and compared to open field data. Results have shown that the surface dose is reduced at all sites within the treatment field with larger reductions seen on one side of the field due to the sweeping nature of the designed magnetic field. Radiographic film extrapolation provides an advanced surface dose assessment and has matched well with Attix chamber results. Film measurement allows for easy 2 dimensional dose assessments.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Nilsson, B. and Brahme, A.,Absorbed dose from secondary electrons in high energy photon beams, Phys. Med. Biol. 24(5): 901–912, 1979.

    Article  CAS  PubMed  Google Scholar 

  2. Petti, P. L., Goodman, M. S., Sisterson, J. M., Biggs, P.J., Gabriel, T.A. and Mohan, R.,Sources of electron contamination for the Clinac-35 25-MV photon beam, Med. Phys. 10(6): 856–861, 1983.

    Article  CAS  PubMed  Google Scholar 

  3. Sjogren, R. and Karlsson, M.,Electron contamination in clinical high energy photon beams, Med. Phys. 23(11):1873–1881, 1996.

    Article  CAS  PubMed  Google Scholar 

  4. Rao, B. M., Prasad, S. G., Parthasaradhi, K., Lee, Y., Ruparel, R. and Garces, R.,Investigations on the near surface dose for three 10 -MV x-ray beam accelerators with emphasis on the reduction of electron contamination, Med. Phys.15 (2):246–249, 1988.

    Article  CAS  PubMed  Google Scholar 

  5. Butson, M. J.,Yu, P., Kan, M., Carolan, M., Young, E., Mathur, J. N. and Metcalfe, P. E.,Skin dose reduction by a clinically viable magnetic deflector, Australasian Physics & Engineering Sciences in Medicine. 20(2):107–110, 1997.

    CAS  Google Scholar 

  6. Bose, L. J., Danciu, C., Cheng, C. W., Brugmans, M. J., van der Horst, A., Minken, A. and Mijnheer, B. J.,Interinstitutional variations of sensitometric curves of radiographic dosimetric films, Med. Phys.29(8):1772–1780, 2002.

    Article  Google Scholar 

  7. Constantinou, C., Attix, F. H. and Paliwal, B. R.,A solid water phantom material for radiotherapy X-ray and gamma ray beam ray calculations, Med. Phys. 9(3): 436–441, 1982.

    Article  CAS  PubMed  Google Scholar 

  8. Butson, M. J., Cheung, T., Yu, P. and Currie, M.,Surface dose extrapolation measurements with radiographic film, Phys. Med. Biol. 49: N197–201, 2004.

    Article  PubMed  Google Scholar 

  9. Butson, M. J., Yu, P. and Metcalfe, P. E.,Extrapolated surface dose measurements with radiochromic film, Med. Phys. 26(3): 485–488, 1999.

    Article  Google Scholar 

  10. Rawlinson, J. A.,Design of parallel plate ion chambers for build up measurements in megavoltage photon beams, Med Phys. 19(3): 641–648, 1992.

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to M. Butson.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Damrongkijudom, N., Butson, M. & Rosenfeld, A. Extrapolated surface dose measurements using a NdFeB magnetic deflector for 6 MV x-ray beams. Australas. Phys. Eng. Sci. Med. 30, 46–51 (2007). https://doi.org/10.1007/BF03178409

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF03178409

Key words

Navigation