Intensity modulated radiotherapy dosimetry with ion chambers, TLD, MOSFET and EDR2 film

  • Scientific Papers
  • Published:
Australasian Physics & Engineering Sciences in Medicine Aims and scope Submit manuscript

Abstract

Purpose of this study was to report in a together our experience of using ion chambers, TLD, MOSFET and EDR2 film for dosimetric verification of IMRT plans delivered with dynamic multileaf collimator (DMLC). Two ion chambers (0.6 and 0.13 CC) were used. All measurements were performed with a 6MV photon beam on a Varian Clinac 6EX LINAC equipped with a Millennium MLC. All measurements were additionally carried out with (LiF:Mg,TI) TLD chips. Five MOSFET detectors were also irradiated. EDR2 films were used to measure coronal planar dose for 10 patients. Measurements were carried out simultaneously for cumulative fields at central axis and at off-axis at isocenter plane (±1, and ±2cm). The mean percentage variation between measured cumulative central axis dose with 0.6 cc ion chamber and calculated dose with TPS was −1.4% (SD 3.2). The mean percentage variation between measured cumulative absolute central axis dose with 0.13 cc ion chamber and calculated dose with TPS was −0.6% (SD 1.9). The mean percentage variation between measured central axis dose with TLD and calculated dose with TPS was −1.8% (SD 2.9). A variation of less than 5% was found between measured off-axis doses with TLD and calculated dose with TPS. For all the cases, MOSFET agreed within ±5%. A good agreement was found between measured and calculated isodoses. Both ion chambers (0.6 CC and 0.13 CC) were found in good agreement with calculated dose with TPS.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Galvin, J. M., Ezzell, G., Eisbrauch, A., Yu, C., Butler, B., Xiao, Y., Rosen, I., Rosenman, J., Sharpe, M., Xing, L., Xia, P., Lomax, T., Low, D. A. and Palta, J.Implementing IMRT in clinical practice: A joint document of the American Society for Therapeutic Radiology and Oncology and the American Association of Physicists in Medicine. Int. J. Radiat. Oncol., Biol., Phys., 58, 1616–34, 2004.

    Article  Google Scholar 

  2. Ezzell, G. A., Galvin, J. M., Low, D. A., Palta, J. R., Rosen, I., Sharpe, M. B., Xia, P., Xiao, Y., Xing, L. and Yu, C. X.Guidance document on delivery, treatment planning, and clinical implementation of IMRT: Report of the IMRT subcommittee of the AAPM radiation therapy committee, Medical Physics, 30, 2089–2115, 2003.

    Article  PubMed  Google Scholar 

  3. Gillis, S., Wagter, C. D., Bohsung, J., Perrin, B., Williams, P. and Mijnheer, B. J.An inter-centre quality assurance network for IMRT verification: Results of the ESTRO QUASIMODO project, Radiother. Oncol. 76, 340–353, 2005.

    Article  PubMed  Google Scholar 

  4. Van, E. A., Bohsung, J., and Sorvari, P.Acceptance tests and quality control (QC) procedures for theclinical implementation of intensity modulated radiotherapy (IMRT) using inverse planning and the sliding window technique: experience from five radiotherapy departments, Radiother. Oncol. 70, 53–70, 2002.

    Google Scholar 

  5. Arnfield, M. R., Wu, Q., Tong, S., and Mohan, R.Dosimetric validation for multileaf collimator-based intensity-modulated radiotherapy: A review, Med. Dosim. 26, 179–188, 2001.

    Article  CAS  PubMed  Google Scholar 

  6. Leybovich, L. B., Sethi, A., and Dogan, N.Comparison of ionization chambers of various volumes for IMRT absolute dose verification, Med Phys, 30, 119–23, 2003.

    Article  PubMed  Google Scholar 

  7. Bouchard, H. and Seuntjens, J.Ionization chamber-based reference dosimetry of intensity modulated radiation beams, Med. Phys. 31, 2454–65, 2004.

    Article  CAS  PubMed  Google Scholar 

  8. Doblado, F., Capote, R., Rosello, J. V., Leal, A., Lagares, J. I., Arrans, R. and Hartmann, G. H.Micro ionization chamber dosimetry in IMRT verification: Clinical implications of dosimetric errors in the PTV, Radiother. Oncol. 75, 342–8, 2005.

    Article  Google Scholar 

  9. Chuang, C. F., Verhey, L. J. and Xia, P.Investigation of the use of MOSFET for clinical IMRT dosimetric verification, Med. Phys. 29, 1109–15, 2002.

    Article  PubMed  Google Scholar 

  10. Shi, C., Papanikolaou, N., Yan, Y., Weng, X. and Jiang, H.Analysis of the sources of the source of uncertainty for EDR2 film-based IMRT quality assurance, J. Appl. Clin. Med. Phys. 7, 1–8, 2006.

    Article  CAS  PubMed  Google Scholar 

  11. Kulasekere, R., Moran, J. M., Fraass, B. A. and Roberson, P. L.Accuracy of rapid radiographic film calibration for intensity-modulated radiation therapy verification, J. Appl. Clin. Med. Phys. 7, 86–95, 2006.

    Article  PubMed  Google Scholar 

  12. Moran, J. M., Radawski, J. and Fraass, B. A.A dose-gradient analysis tool for IMRT QA, J. Appl. Clin. Med. Phys. 6, 62–72, 2005.

    Article  PubMed  Google Scholar 

  13. Halvorsen, P. H.Dosimetric evaluation of a new design MOSFET in vivo dosimeter, Med Phys. 32, 110–7, 2005.

    Article  PubMed  Google Scholar 

  14. Kinhikar R. A., Sharma P. K., Tambe C. M. and Deshpande D. D.Dosimetric evaluation of a new OneDose MOSFET for Ir-192 energy, Phys Med Biol. 51, 1261–8, 2006.

    Article  PubMed  Google Scholar 

  15. Kinhikar, R. A., Sharma, P. K., Tambe, C. M., Mahantshetty, U. M., Sarin, R., Deshpande, D. D. and Shrivastava, S. K.Clinical application of Onedose Mosfet for skin dose measurements during internal mammary chain irradiation with high dose rate brachytherapy in Carcinoma of Breast, Phys Med Biol. 51, N263-N268, 2006.

    Article  PubMed  Google Scholar 

  16. Low, D. A., Harms, W. B. and Mutic, S.A technique for the quantitative evaluation of dose distributions, Med. Phys. 25, 656–61, 1998.

    Article  CAS  PubMed  Google Scholar 

  17. Low, D. A. and Dempsey, J. F.Evaluation of the gamma dose distribution comparison method, Med. Phys. 30, 2455–64, 2003.

    Article  PubMed  Google Scholar 

  18. Depuydt, T., Esch, A. V. and Huyskens, D. P.A quantitative evaluation of IMRT dose distributions: Refinement and clinical assessment of the gamma evaluation, Radiother Oncol. 62, 309–19, 2002.

    Article  PubMed  Google Scholar 

  19. Papatheodorou, S., Rosenwald, J. C. and Zefkili, S.Dose calculation and verification of intensity modulation generated by multilieaf collimators, Med. Phys. 27, 960–71, 2000.

    Article  CAS  PubMed  Google Scholar 

  20. Chen, Z., Xing, L. and Nath, R.Independent monitor unit calculation for IMRT using MIMiC multileaf collimator, Med. Phys. 29, 2041–51, 2002.

    Article  PubMed  Google Scholar 

  21. Tsai, J. S., Wazer, D. E., and Ling, M. N.Dosimetric verification of the dynamic intensity-modulated radiation therapy of 92 patients, Int. J. Radiat. Oncol.Biol. Phys. 40, 1213–30, 1998.

    CAS  PubMed  Google Scholar 

  22. Xia, P. and Change, C.Patients specific quality assurance in IMRT, In: Palta, J. R., Mackie, T. R., editors. Intensity-Modulated Radiation Therapy.The State of the Art.Medical Physics Monograph No. 29. Madison, WI: Medical Physics Publishing; 495–514, 2003.

    Google Scholar 

  23. Olch, A. J.Dosimetric accuracy of the ITP™ inverse treatment planning system, Med. Phys. 29, 2484–88, 2002.

    Article  PubMed  Google Scholar 

  24. Kapulsky, A., Mullokandov, E. and Gejerman, G.An automated phantom-film QA procedure for intensitymodulated radiation therapy, Med. Dosim. 27, 201–207, 2002.

    Article  CAS  PubMed  Google Scholar 

  25. Palta, J. R., Kim, S. and Liu, C.Tolerance limits and action levels for planning and delivery of IMRT. In: Palta, J. R., Mackie, T. R., editors.Intensity-Modulated Radiation Therapy. The State of the Art. Medical Physics Monograph No. 29. Madison, WI: Medical Physics Publishing; 593–612, 2003.

    Google Scholar 

  26. American Association of Physicists in Medicine. Radiation Therapy Committee Task Group 53:Quality assurance for clinical radiotherapy treatment planning. Med. Phys. 25, 1773–829, 1998.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to R. A. Kinhikar.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kinhikar, R.A., Upreti, R., Sharma, S. et al. Intensity modulated radiotherapy dosimetry with ion chambers, TLD, MOSFET and EDR2 film. Australas. Phys. Eng. Sci. Med. 30, 25–32 (2007). https://doi.org/10.1007/BF03178406

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF03178406

Key words

Navigation