Summary
The amperometric estimation of copper with resacetophenone-oxime was carried out by titration in 10% aqueous alcoholic medium at pH 4·8 and an applied voltage of − 0·60V (vs. merucry pool anode). Results within ± 1% error were obtained for amounts ranging from 2·0 to 10·0 mg. and as much as five times its weight of cadmium or nickel did not interfere.
Similar content being viewed by others
References
Appala Raju, N. and Neelakantam, K.Curr. Sci., 1950,19, 383–84.
Bhatki, K. S. and Kabadi, M. B.J. Sci. and Ind. Res. (India), 1953,12 B, 226.
—————..J. Univ. Bombay (N.S.), 1955,24 A (3), 51–57.
Arthur, I. Vogel ..A Text-Book of Practical Organic Chemistry, 1948, p. 685.
----- ..A Text-Book of Quantitative Inorganic Analysis, 1962, p. 358.
----- ..Ibid., 1962, p. 901.
Author information
Authors and Affiliations
Additional information
Communicated by Dr. K. Neelakantam,f.a.sc.
Rights and permissions
About this article
Cite this article
Krishna Reddy, Y. Amperometric estimation of copper with resacetophenone-oxime. Proc. Indian Acad. Sci. 61, 368–373 (1965). https://doi.org/10.1007/BF03049258
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF03049258