Abstract
In this work, the average perturbed angular correlation integral attenuation factor G2 of the transferrin in the serums from the normals and the patients with liver cancer were determined using time integral perturbed angular correlation method (PAC). The average values of G2 were 0.1945±0.0155 for the cancer serum transferrin and 0.2865±0.0411 for the normal serum transferrin. The difference between these two groups is significant. Mathematical deduction and theoretical analysis suggested that the equivalent radius of the transferrin molecules in the serum of cancer patients becomes smaller than normal, because of a change in the molecular conformation. Similar results were also observed in experiments with rat serum transferrin.
Similar content being viewed by others
References
Ni, Xinbo, Wang, Yongxian, Sun, Qixun, et al. (1981),Nuclear Techniques 2, 37.
Ni, Xinbo, Jiang, Dazhen, and Yang, Jinqing (1979),Nuclear Techniques 1, 32.
Marshall, A. G. and Meares C. F. (1972),J. Chem. Phys. 56, 1226.
Wallach, D. (1967),J. Chem. Phys. 47, 5258.
Wang, Yongxian, Ni, Xinbo, Chen, Wenbiao, to be published.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Wang, Y., Ni, X., Chen, W. et al. Measurement of serum transferrin by the γ−γ perturbed angular correlation method. Biol Trace Elem Res 22, 1–7 (1989). https://doi.org/10.1007/BF02917411
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02917411