Skip to main content
Log in

Development of a functional fixator system for bone deformity near joints

  • Published:
Journal of Mechanical Science and Technology Aims and scope Submit manuscript

Abstract

A functional external fixator system for bone deformity near the joints using worm gear was developed for curing the angle difference in fracture bones while the lengthening bar was developed for curing the differences in length, also in fracture bones. Both experiments and FE analysis were performed to compare the elastic stiffness in several loading modes and to improve the functional external fixator system for bone deformity near joints. The FE model using compressive and bending FE analysis was applied due to the angle differentiations. The results indicate that compressive stiffness value in the experiment was 175.43 N/mm, bending stiffness value in the experiment was 259.74 N/mm, compressive stiffness value in the FEA was 188.67 N/mm, and bending stiffness value in the FEA was 285.71 N/mm. Errors between experiments and FEA were less than 10% in both the compressive stiffness and the bending stiffness. The maximum stress (l57 MPa) applied to the angle of the clamp was lower than the yield stress (176.4 MPa) of SUS316L. The degree of stiffness in both axial compression and bending of the new fixator are about 2 times greater than other products, with the exception of EBI (2003).

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Behrens, F., 1989, “General Theory and Principles of External Fixation,”Clin Orthop, Vol. 241, pp. 15~23.

    Google Scholar 

  • Kim, H. T., Lee S. H., 2000, Clinical Application of Domestic External Fixator System (Dyna-Extor),”Korean Orthopaedic Association Journal, Vol. 35, pp. 845~849.

    Google Scholar 

  • Koo, T. K. K., Kim, Y. H., Choi, D. B., Jua, K. G., Lim, J., Inoue, N. and Chao, E. Y. S., 2003, Stiffness Analysis of Dynafix External Fixator System,2003 Summer Bioengineering Conference, pp. 1227–1228.

  • Kristiansen, T., Fleming, B., Reinecke, S. and Pope, M. H., 1987, “Comparative Study of Fracture Gap Motion in External Fixation,”Clinical Biomechanics, Vol. 2–4, pp. 191~195.

    Google Scholar 

  • Lee, M. K., Choi, K. and Choi, I,H., 2002, The Effect of Mechanical Dynamization on Regenerative Bone Healing,Porceedings of the Korean Society of Precision Engineering Conference, pp. 158–161.

  • Oh, J. K. and Park, J. H, 1998, “Axial Stiffness of the Ilizarov External Fixator System Using Rancho Method,”Korean Orthopaedic Association Journal, Vol. 33, No. 7, pp. 1928~1932.

    Google Scholar 

  • Paley, D., Flemming, B., Catagni, M., Kristiansen, T. and Pope, M., 1990, “Mechanical Evaluation of External Fixators Used Limb Lengthening,”Ctin Orthop, Vol. 250, pp. 50~57.

    Google Scholar 

  • Perren, S. M., 1979, “Physical and Biological Aspects of Fracture Healing with Special Reference to Internal Fixation,”Ctin Orthop, Vol. 138, pp. 175~196.

    Google Scholar 

  • Sisk, T. D., 1983, “External Fixation, Historic Review, Advantage, Complications, and Indications,”Ctin Orthop, Vol. 180, pp. 15~22.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Keyoung Jin Chun.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Chun, K.J., Lee, H.J. Development of a functional fixator system for bone deformity near joints. J Mech Sci Technol 20, 234–241 (2006). https://doi.org/10.1007/BF02915825

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02915825

Key Words

Navigation