Skip to main content
Log in

An analysis on the diagnostic values of transcranial Doppler and angiography in transient ischemic attack

  • Published:
Current Medical Science Aims and scope Submit manuscript

Summary

The accuracy and diagnostic values of transcranial Doppler (TCD) in transient ischemic attack (TIA) caused by the stenosis or occlusion of intracranial or extracranial blood vessels were investigated. Of the 50 TIA patients receiving routine TCD examinations, 39 cases (77%) were diagnosed as having unilateral or bilateral stenosis or occlusion of MCA, ACA, siphon segment of internal carotid artery, which was furthermore confirmed by digital subtraction angiography (DSA) or MRA, 11 (22 %) cases were normal. An analysis on the TCD findings of the flow patterns and hemodynamic changes of the stenotic or occluded blood vessels was made in comparison with that obtained by angiography. It was showed that angiography demonstrated 17 unilateral MCA stenosis, 47 bilateral multi-stenosis, 1 occlusion of the siphon segment of the internal carotid artery, while TCD revealed 17 unilateral stenosis, 64 bilateral stenosis, 1 occlusion respectively, with an accordance rate of 78.7%. It was concluded that the hemodynamic changes secondary to the stenosis of the basalcranial arteries, especially the moderate to severe stenosis or occlusion, might be an important risk factor for TIA. TCD examination achieved significant clinic values in the diagnosing of TIA.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. 1996,29:379

  2. Widder B. Anwendungen in der Intensivemedizin Dopper- und Duplexsonograpie der hirversorgenden arterien, Berlin: Springer, 1995. 346

    Google Scholar 

  3. 1991,7:283

  4. Giovannoni G, Fritz V U. Transient ischemic attacks in younger and older aatients: A comparative study of 798 patients in South Africa. Stroke, 1993, 24:947

    Article  CAS  PubMed  Google Scholar 

  5. 1995,12:296

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Yaping, J., Jingqiong, H. & Qiong, G. An analysis on the diagnostic values of transcranial Doppler and angiography in transient ischemic attack. Current Medical Science 21, 100–101 (2001). https://doi.org/10.1007/BF02888066

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02888066

Key words

Navigation