Abstract
End tidal Carbon dioxide monitoring was undertaken prospectively in all Ventilated neonates in our NICU admitted from March 1995 to August 1995 irrespective of the birth weight, gestational age and indication of ventilation. The aim was to determine the correlation between ETCO2 and PaCO2 in various clinical situations. The arterial blood gases were obtained in all ventilated babies with simultaneous and continuous ETCO2 monitoring and were analysed by AVL 995 Hb blood gas analyser. ETCO2 was analysed by side stream technique by Datex Cardiocap II monitor. A total of 152 samples from in-dwelling radial artery catheters were analysed from babies with birth weight from 900 g to 3400 g, gestation age from 28 to 42 wks and were ventilated for various indications like Severe Birth Asphyxia (SBA), Meconium Aspiration Syndrome (MAS), Recurrent Apnoea and Hyaline Membrane Disease (HMD). Statistical analysis was done in 10 groups to see if the ETCO2 correlated with its corresponding PaCO2 value. The study groups comprised three groups based on birth weight being <1.5–2.5 kg and >2.5 kg three groups as per the gestational age being 28–31+6 wks, 32–36+6 wks and 37–41+6 wks and four groups as per the need for ventilation being Severe Birth Asphyxia, Meconium Aspiration Syndrome, Apnoea of Prematurity and Hyaline Membrane Disease. Results of the correlation analysis revealed that the correlation coefficient in the study group ranged from 0.55 to 0.96 and was statistically significant in babies >2.5 kg and 1.5–2.5 kg, in term and preterms 32–36 wks, and in babies with MAS, SBA and Recurrent Apnoea. The correlation coefficient was lowest in babies with HMD, being 0.55. The study showed that ETCO2 correlates closely with PaCO2 in most clinical situations in neonates and we recommend its use in all level III NICUs in ventilated babies.
Article PDF
Similar content being viewed by others
References
Cloherty JP, Snyder EY. Blood Gas monitoring.Manual neonatal care 1992: 3rd edn: 209–215.
Jone IraZurta. Monitoring in Paediatric Intensive care.Ind Jour Paed. 1993; 60: 55–65.
Adams AP. Capnography and Pulse oximetry.Recent advances in Anaesthesia and Analgesia. Churchill Livingstone. No. 16, 1989; 55–175.
Paloheimo M, Valli M, Ahjopalo H.A guide to CO 2 monitoring. Datex instrumentation Corp., 1983.
M. Ramex Salem. Hypercapnia, hypocapnia and Hypoxaemia.Seminars in Anaesthesia, 1987; Vol. 6: 3 (Sept.): 202–215.
Swedlow David B. Capnometry and Capnography; The anaesthesia Disaster early warning system.Seminars in anesthesia, 1986; Vol. 5: 3 (Sept.): 194–206.
Geven WB, Nagler E, Th. de Boo and W. Lemmens. Combined transcutaneous Oxygen, Carbon dioxide tensions and end expired CO2 levels in severely ill newborns.Adv Exp Med Biol. 1987; 220: 115–120.
Ward SA. The capnogram: Scope and limitations.Seminars in Anaesthesia 1987; 3: 216–228.
Rolf Lanber, Bruno Seeberget MD, Alex Martin Zbinden. Carbondioxide analysers: accuracy, alarm limits and effects of interfering Gases.Can J Anaesth, 1995; 42: 7: 643–656.
Fleether R. Airway Dead space. ETCO2 and Christian bohr.Acta Anaesthesiol Scand. 1984; 28: 408–411.
Lillie PE, Roberts JG. CO2 monitoring.Anaesthesia Intensive Care, 1988; 16: 41–44.
Haab P. Factors influencing magnitude of the CO2 partial pressures in the body.Intensive Care Med. 1981; 7: 250.
Pryds O, Andersen GE, Friis-Hansen B. Cerebral blood flow reactivity in spontaneously breathing, preterm infants shortly after birth.Acta Paediatr Scand 1990; 79, 391–396.
National Committee for Clinical Laboratory Standards. Procedures for the collection of diagnostic blood specimens by skin puncture. 3rd NCCLS publication, Pennsylvania: 1991.
Mastering Infra-red Capnography. Z. Kalenda. Kerckebosch.-III. Netherlands, 1989; 49–172.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Nangia, S., Saili, A. & Dutta, A.K. End tidal carbon dioxide monitoring—Its reliability in neonates. Indian J Pediatr 64, 389–394 (1997). https://doi.org/10.1007/BF02845211
Issue Date:
DOI: https://doi.org/10.1007/BF02845211