Skip to main content
Log in

Analysis of HPGe-detector relative photopeak efficiency

  • Published:
Il Nuovo Cimento A (1965-1970)

Summary

The dependence of the HPGe-detector efficiency on its intrinsic and geometrical properties such as energy resolution, electronic noise, charge production statistics and effect of the rise time is considered. This study also includes the detector's sensitive volume. Efficiencies of a 0.55 cm3 planar and 46.3, 56.4 and 62.3 cm3 active volume of coaxial HPGe-detectors have been estimated for γ-ray energies from 50 to 1000 keV only, for a point source. Agreement has been found between the present calculated and published experimental efficiencies.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Becker J., Dissertation, Institute of Physics, University of Stockholm (1979).

  2. Tokcan G. andCothern C. R.,Nucl. Instrum. Methods,64 (1968) 219.

    Article  ADS  Google Scholar 

  3. Paradellis T. andHontzeas S.,Nucl. Instrum. Methods,73 (1969) 210.

    Article  ADS  Google Scholar 

  4. Seyfarth H., Hassan A. M., Hrastik B., Gottel P. andDelang W.,Nucl. Instrum. Methods,105 (1972) 301.

    Article  ADS  Google Scholar 

  5. Seyfarth H.,Nucl. Instrum. Methods.,114 (1974) 125.

    Article  ADS  Google Scholar 

  6. Chapman G. T.,Nucl. Instrum. Methods,52 (1967) 101.

    Article  ADS  Google Scholar 

  7. Goulding F. S., Pehl R. H. andLandis D. A.,Nuclear Spectroscopy and Reactions, edited byJ. Cerny, PartA (Academic Press, New York and London) 1974, Chapt. III A, III D, p. 292 and 421.

    Google Scholar 

  8. Singh B. P. andEvans H. C.,Nucl. Instrum. Methods,97 (1971) 475.

    Article  ADS  Google Scholar 

  9. ORTEC,Nuclear Instruments and Systems, Catalog (1986/87), pp. 2–4, 3–10.

  10. Vano E., Gonzalez L., Gaeta R. andGonzalez J. A.,Nucl. Instrum. Methods,123 (1975) 573.

    Article  ADS  Google Scholar 

  11. Grant P. M.,Nucl. Instrum. Methods,127 (1975) 371.

    Article  ADS  Google Scholar 

  12. Abou-Leila H., Ismail H. A., Kamal M. andEl-Ashry A.,Atomkernenergie (ATKE), Bd33, Lfg. 1,Kernphysik (1979) 50.

    Google Scholar 

  13. Ismail H. andMalaak S. A.,Atomkernenergie (ATKE), Bd.40, Lfg. 3,Kernphysik (1982) 209.

    Google Scholar 

  14. El-Kameesy S. U.,Scientist Phil. Science,3, No. 2 (1991) 130 and private communication of the experimental data concern with the four HPGe-detector efficiencies.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

El-Khosht, M.A. Analysis of HPGe-detector relative photopeak efficiency. Nuov Cim A 108, 659–668 (1995). https://doi.org/10.1007/BF02813373

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02813373

PACS

Navigation