Abstract
The principle for designing the shifting image section of an intensifier silicon target pick-up tube is given. An electrostatic electron-optical system with a photocathode having an effective diameter of 40mm and a system magnification of 0.65 has been designed. Experiments show that when the electron image of the photocathode is transferred to the silicon target, the geometric distortion is 2%, and the field curvature is 2mm. The astigmatism is less than 0.32 mm at 80 percent of the viewing field and the resolution is over 50 Ip/mm. It shows that the design of the electron-optical system is good and reasonable.
Similar content being viewed by others
References
B. Singer,IEEE Trans. on Ed.,ED-18 (1971), 1016.
S. Miyashiro and S. Shirouzu,IEEE Trans. on ED,ED-18 (1971), 1023.
Author information
Authors and Affiliations
About this article
Cite this article
Liang, L., Zhihua, G. & Weijun, Y. The design of the shifting section of an intensifier silicon target pick-up tube. J. of Electron. (China) 1, 207–212 (1984). https://doi.org/10.1007/BF02778404