Skip to main content
Log in

Comparison of axial and radial flow chromatography on protein separation speed and resolution

  • Published:
Korean Journal of Chemical Engineering Aims and scope Submit manuscript

Abstract

Fluid dynamic behavior, particularly the relationship between pressure drop and liquid flowrate, inside an axial and a radial flow Chromatographic column packed with compressible porous media was theoretically analyzed using the modified Kozeny-Carman equation. The results were compared with experimental observations obtained using compressible DEAE-agarose as a model medium. At the 2–9 psi pressure drop range studied, theoretical derivation accounting for the gel compression’ effect predicted simple Langmuirian-type response of volumetric flowrate to changes in pressure drop. On the other hand, the experimental result was more or less sigmoidal. At the same pressure drop, radial column yielded 2–3 times higher flowrates than those of axial column both theoretically and experimentally. Using r-HBsAg crude extract, protein resolution effects between the two types of columns at various flowrates were compared side-by-side. Though general Chromatographic behaviors were very similar, the axial column was somewhat superior in terms of rHBsAg recovery yield and specificity. However, the number of theoretical plates analysis indicated the protein resolution effects were comparable.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Afeyan, N. B., Fulton, S. P. and Regnier, F. E., “Perfusion Chromatography Material for Proteins and Peptides,J. Chromatography,544, 267 (1991).

    Article  CAS  Google Scholar 

  • Cramer, S. M. and Jayaraman, G.,“Preparative Chromatography in Biotechnology,Current Optinion in Biotechnology,4, 217 (1993).

    Article  CAS  Google Scholar 

  • Ergun, S.,“Fluid Flow through Packed Columns”,Chem. Eng. Progr.,48, 89 (1952).

    CAS  Google Scholar 

  • Lee, W. C., Tsai, G. J. and Tsao, G. T., Protein Purification: from Molecular Mechanisms to Large-Scale Processes”, Ladisch et al. ed., 104 (ACS Symposium Series, 427) (1990).

  • Mant, C. T. and Hodges, R. S.,“High-Performance Liquid Chromatography of Peptides and Proteins: Separation, Analysis, and Conformation”, CRC Press, Boca Raton, FL, USA (1991).

    Google Scholar 

  • McCabe, W. L. and Smith, J. C.,“Unit Operations of Chemical Engineering”, 4th ed., McGraw-Hill, New York, NY, USA (1985).

    Google Scholar 

  • Saxena, V. and Weil, A. E.,“Novel Radial Flow Columns for Scaling Up Chromatographic Separations”,Biochromatography,2(2), 90 (1987).

    CAS  Google Scholar 

  • Saxena, V., Subramanian, K., Saxena, S. and Dunn, M., ”Radial Flow Columns for Protein Separation”,Biopharm.,2(3), 34 (1989).

    Google Scholar 

  • Saxena, V., Weil, A. E., Kawahata, R. T., McGregor, W. C. and Chandler, M., “Applications of Radial Flow Columns for Fast Affinity Chromatography,American Laboratory News,19, 112(1987).

    CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kim, YH., Lee, E.K. Comparison of axial and radial flow chromatography on protein separation speed and resolution. Korean J. Chem. Eng. 13, 466–472 (1996). https://doi.org/10.1007/BF02705995

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02705995

Key words

Navigation