Abstract
A calculation technique for contact heat exchangers operating in the regime of complete evaporation is proposed that employs two basic approaches to solution of the problem on evaporative cooling of gases. The first approach is based on balance equations, and the second on determination of local parameters of the process.
Similar content being viewed by others
References
N. M. Savitskaya, A. Yu. Val'dberg, and É. Ya. Tarat, Inzh.-Fiz. Zh.,26, No. 2, 353–356 (1979).
A. A. Rusanov (ed.), Handbook on Dust and Ash Trapping [in Russian], Moscow (1983).
Additional information
Research Institute for Industrial and Sanitary Decontamination of Gases, Moscow, Russia. Translated from Inzhenerno-Fizicheskii Zhurnal, Vol. 69, No. 6, pp. 982–985, November–December, 1996.
Rights and permissions
About this article
Cite this article
Val'dberg, A.Y., Savitskaya, N.M. An approach to the design calculation of contact heat exchangers operating in the regime of complete evaporation of a spraying liquid. J Eng Phys Thermophys 69, 753–756 (1996). https://doi.org/10.1007/BF02606110
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF02606110