Skip to main content
Log in

Clinical applications of characteristic frequency measurements: preliminaryin vivo study

  • CAIT Communication
  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

In vivo electrical impedance tomography images have been available for some years, and most of them show variation in impedance amplitude between two different states, for example between inspiration and expiration of the lungs. A refinement of the tomography technique has made it possible to show images of the complex impedance of the body. If several frequencies are used, more information on the investigated tissues can be collected, and new areas made available for investigation. It has been shown that tissues exhibit a characteristic frequency that can be derived from the maximum magnitude of the (negative) reactance. The characteristic frequency-related images can be calculated from several imaginary part curves obtained using the back-projection technique. The paper shows in vivo impedance spectra from different parts of the body, determines the characteristic frequency of the different in vivo measurements and suggests different applications of characteristic frequency imaging. Several data sets are collected to show the reproducibility of the measurements.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Barber, D. C., andBrown, B. H. (1984): ‘Allied potential tomography’,J. Phys. E Sci. Instr.,17, pp. 723–733

    Article  Google Scholar 

  • Crile, G. W., Hosmer, H. R., andRowland, A. F. (1922): ‘The electrical conductivity of animal tissues under normal and pathological conditions’,Am. J. Physiol.,60, pp. 59–106

    Google Scholar 

  • Geddes, L. A., andBaker, L. E. (1967): ‘The specific resistance of biological material—a compendium of data for the biomedical engineer and phsiologist’,Med. Biol. Eng.,5, pp. 271–293

    Article  Google Scholar 

  • Gersing, E., Bach, F., Brockhoff, C., Gebhard, M. M., Kehrer, G., Meissner, A., andBretschneider, H. J. (1991): ‘Messung der elektrischen Impedanz von Organen—Methodische Grundlagen’,Biomedizinische Technik,36, (4) pp. 70–77

    Article  Google Scholar 

  • Kanai, H. (1992): ‘Frequency characteristics of electrical properties of living tissues and its clinical application’. Proc. 8th Int. Conf. on Electrical Bio-impedance, Kuopio, Finland, University of Kuopio and Int. Committee for Promotion of Research in Bio-Impedance, pp. 5–7

  • Pethig, R. (1984): ‘Dielectric properties of biological materials: biophysical and medical applications’,IEEE Trans.,EI-19, (5), pp. 453–474

    Google Scholar 

  • Pethig, R. (1987): ‘Dielectric properties of body tissues’,Clin. Phys. Physiol. Meas.,8, Suppl. A, pp. 5–12

    Article  Google Scholar 

  • Pliquett, F., andPliquett, U. (1992): ‘Tissue impedance, measured by pulse deformation’. Proc. 8th Int. Conf. on Electrical Bioimpedance Kuopio, Finland, pp. 179–181

  • Schwan, H. (1941): ‘Uber die Niederfrequenzleitfähigkeit von Blut und Blutserum verschiedenen temperature’. Kaiser Wilhelm-Institute fur Biophysik, Frankfurt AM, pp. 531–545

    Google Scholar 

  • Yamamoto, Y. (1994): ‘Measurements and analysis of skin electrical impedane’,Acta Derm. Venereol. (Stockholm), Suppl. 185, pp. 34–38

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Blad, B. Clinical applications of characteristic frequency measurements: preliminaryin vivo study. Med. Biol. Eng. Comput. 34, 362–365 (1996). https://doi.org/10.1007/BF02520006

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02520006

Keywords

Navigation