Abstract
The reliability of the single comparator method depends mainly on the accuracy of k factors. This paper describes error in theoretical k factors, especially that due to the scattering in literature data for thermal and epithermal neutron activation cross-sections. Error calculations were performed for thirteen elements using comparator sets of60Co−198Au and95Zr−97Zr to evaluate the accuracy of this method.
Similar content being viewed by others
References
K. FUJINAGA, K. KUDO, J. Radioanal. Chem., 52 (1979) 409.
K. FUJINAGA, Radioisotopes 28 (1979) 763.
K. FUJINAGA, (to be published).
F. GIRARDI, G. GUZZI, J. PAULY, Anal. Chem., 37 (1965) 1085.
F. DE CORTE, A. SPEECKE, J. HOSTE, J. Radioanal. Chem., 3 (1969) 205.
A. SIMONITS, F. DE CORTE, J. HOSTE, J. Radioanal. Chem., 31 (1976) 467.
R. VAN DER LINDER, F. DE CORTE, J. HOSTE, J. Radioanal. Chem., 13 (1976) 169.
A. SIMONITS, F. DE CORTE, J. HOSTE, J. Radioanal. Chem., 24 (1975) 31.
K. FUJINAGA, K. KUDO, Anal. Chim. Acta, 110 (1979) 75.
R. VAN DER LINDEN, F. DE CORTE, P. VAN DEN WINKEL, J. HOSTE, J. Radioanal. Chem., 11 (1972) 133.
E. M. CRYNTAKIS, J. I. KIM, J. Radioanal. Chem., 29 (1976) 175.
L. MOENS, F. DE CORTE, J. HOSTE, A. SIMONITS, J. Radioanal. Chem., 45 (1978) 221.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Fujinaga, K. Error estimation of the single comparator method due to uncertainties of literature data for thermal and epithermal neutron activation cross-sections. J. Radioanal. Chem. 57, 29–35 (1980). https://doi.org/10.1007/BF02519861
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/BF02519861