Skip to main content
Log in

A Compton suppression gamma-ray spectrometer for low level counting

I. Radioanalytical evaluation

  • Physical Methods Section
  • Published:
Journal of Radioanalytical Chemistry Aims and scope Submit manuscript

Abstract

A Compton suppression gamma-ray spectrometry system has been evaluated for its use as a low level radioactivity counting facility. The system consists of a premium quality Ge(Li) detector surrounded by a shield of NaI(T1) detector material. Compton suppression is obtained by operating the two detector systems in anti-coincidence. Spectrum collection hardware consists of a NP11-A (DEC) interface for two ADC's and a PDP 11/T 10 minicomputer with 64 K byte core memory. Software development and system operation modes are described. System performance as a function of physical characteristics of the sample, scattering angle and gamma-photon energy, is discussed. Continum reduction for cascaded gamma-transitions and natural backgorund are considered separately.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. J. KANTELE, P. SUOMINEN, Nucl. Instr. Meth., 41 (1966) 41.

    Article  CAS  Google Scholar 

  2. G. V. WALFORD, R. M. KEYSER, The evaluation of system sensitivity and capability of a NAI(T1) shielded Ge(Li)-detector, ORTEC-report, 1977.

  3. N. A. WOGMAN, Nucl. Instr. Meth., 83 (1970) 277.

    Article  CAS  Google Scholar 

  4. J. A. COOPER, R. W. PERKINS, Nucl. Instr. Meth., 99 (1972) 125.

    Article  CAS  Google Scholar 

  5. Y. SEVERT, J. Lippert Nucl. Instr. Meth., 33 (1965) 347.

    Article  Google Scholar 

  6. R. L. CURRIE, R. Mc PHERSON, G. H. MORRIS, Modern Trends in Activation Analysis, NBS-Special Publications 312, Vol. II, 1969, p. 1062.

    Google Scholar 

  7. S. R. LEWIS, N. H. SHAFRIR, Nucl. Instr. Meth., 93 (1971) 317.

    Article  CAS  Google Scholar 

  8. N. A. WOGMAN, D. E. ROBERTSON, R. W. PERKINS, Nucl. Instr. Meth., 50 (1967) 1.

    Article  CAS  Google Scholar 

  9. J. M. NIELSEN, R. W. PERKINS, Radioactive Dating and Methods for Low Level Counting, IAEA, Vienna, 1967.

    Google Scholar 

  10. J. A. COOPER, L. A. RANCITELLO, R. W. PERKINS, W. A. HALLER, A. L. JACKSON, Modern Trends in Activation Analysis, NBS-Special Publications 312, Vol. II, 1969, p. 1054.

    Google Scholar 

  11. J. OP DE BEECK, J. DE DONDER, PHANAL: Exploitation Software Package for a PHA 11 Pulse Height Analysis System, unpublished work, 1978.

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Op De Beeck, J., Isebaert, A. & Hoste, J. A Compton suppression gamma-ray spectrometer for low level counting. J. Radioanal. Chem. 76, 225–239 (1983). https://doi.org/10.1007/BF02519672

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02519672

Keywords

Navigation