Abstract
In the production of131I, the presence of a contamination extractable with organic solvents has been detected and its source discovered. The influence of overheating was established in the preparation of99mTc by the extraction method. Finally, details are given of the procedure used for the estimation of199Au present in198Au.
Similar content being viewed by others
References
Radioisotope Production and Quality Control. IAEA, Technical Reports Series No. 128, Vienna, 1971, p. 262.
Radioisotope Production and Quality Control. IAEA, Technical Reports Series No. 128, Vienna, 1971, p. 717.
Radioisotope Production and Quality Control. IAEA, Technical Reports Series No. 128, Vienna, 1971, p. 201.
Y. Cohen, Radioactive Pharmaceuticals. USAEC, Div. of Technical Information, Symp. Ser. 6, 1966, p. 67.
E. P. Belkas, D. C. Perricos,Radiochim. Acta, 11 (1969) 56.
H. S. Stern, J. G. McAfee, G. Subramanian,J. Nucl. Med., 7 (1966) 665.
P. Veselý, J. Cifka, Radiopharmaceuticals from Generator-produced Radionuclides. IAEA, Vienna, 1971, p. 71, STI/PUB/294.
E. Lewis,Nucl. Appl., 2 (1966) 33.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Belkas, E.P., Archimandritis, S. Some observations on the radionuclidic and radiochemical control of radiopharmaceuticals at the N.R.C. Democritos. J. Radioanal. Chem. 13, 469–474 (1973). https://doi.org/10.1007/BF02513938