Abstract
The fully automated on-line trace enrichment of 27 (polar) pollutants, using volumes of up to 1,000 mL, on a polymeric precolumn followed by liquid chromatography —diode-array detection has been studied. Various parameters influencing the reproducibility of these large volume injections like breakthrough volume, precolumn capacity, matrix effects, and enrichment flow rate are discussed. The relative standard deviation of the recoveries after enrichment of 25–500 mL of sample is 1–20%. Enrichment flow rates up to 15 mL min−1 can be used with an optimum at 10 mL min−1. A pore size of 300 A provides the best results using the polymeric PLRP-S material. The breakthrough volumes show significant dependence upon the concentration of the analytes in the sample.
Similar content being viewed by others
References
I. Liška, J. Krupcík, P. A. Leclerq, J. High Resolut. Chromatogr.12, 577 (1989).
I. Liška, E. R. Brouwer, A. G. L. Ostheimer, H. Lingeman, U. A. Th. Brinkman, B. R. Geerdink, W. H. Mulder, Intern. J. Environ. Anal. Chem.,47, 267 (1992).
I. Slobodník, E. R. Brouwer, R. B. Geerdink, W. H. Mulder, H. Lingeman, U. A. Th. Brinkman, Anal. Chim. Acta,268, 55 (1992).
J. Slobodník, M. G. M. Groenewegen, E. R. Brouwer, H. Lingeman, U. A. Th. Brinkman, J. Chromatogr.,642, 359 (1993).
M. -C. Hennion, Trends In Anal. Chem.,10, 10 (1991).
A. Di Corcia, M. Marchetti, Anal. Chem.,63, 580 (1991).
E. R. Brouwer, D. J. van Iperen, I. Liška, H. Lingeman, U. A. Th. Brinkman, Intern. J. Environ. Anal. Chem.,47, 257 (1992).
H. Bagheri, J. Slobodník, R. M. Marcé Recasens, R. T. Ghijsen, U. A. Th. Brinkman, Chromatographia,37, 159 (1993).
I. Liška, E. R. Brouwer, H. Lingeman, U. A. Th. Brinkman, Chromatographia,37, 13 (1993).
J. Slobodník, A. C. Hogenboom, A. J. H. Louter, U. A. Th. Brinkman, J. Chromatogr. A,730, 353 (1996).
J. Slobodník, A. C. Hogenboom, J. J. Vreuls, J. Rontree, B. L. M. van Baar, W. M. A. Niessen, U. A. Th. Brinkman, J. Chromatogr. A,741, 59 (1996).
J. Slobodník, Ö. Öztezkizan, H. Lingeman, U. A. Th. Brinkman, J. Chromatogr. A,750, 227 (1996).
M. W. F. Nielen, R. W. Frei, U. A. Th. Brinkman, in R. W. Frei, K. Zech, eds.,Selective Sample Handling and Detection in Liquid Chromatography, Part A, Elsevier, Amsterdam, 1988.
M. L. Larrivee, C. F. Poole, Anal. Chem.,66, 139 (1994).
EEC Drinking Water Guideline, 80/779/EEC, EEC No. L229/11-29, EEC, Brussels, August 30th, 1980.
P. Subra, M. -C. Hennion, R. Rosset, R. W. Frei, J. Chromatogr.,456, 121 (1988).
C. E. Werkhoven-Goewie, U. A. Th. Brinkman, R. W. Frei, Anal. Chem.,53, 2072 (1981).
G. R. Aiken, D. M. McKnight, R. L. Wershaw, P. Mac Carthy, Eds.,Humic Substances in Soil, Sediment, and Water, John Wiley & Sons, New York, 1985.
P. J. Schoenmakers, H. A. H. Billiet, L. de Galan, J. Chromatogr.,185, 179 (1979).
L. Nondek, V. Chvalovský, J. Chromatogr.,312, 303 (1984).
A. E. Rodrigues, LC-GC Intl.,6, 20 (1992).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Slobodník, J., Lingeman, H. & Brinkman, U.A.T. Large-volume liquid chromatographic trace-enrichment system for environmental analysis. Chromatographia 50, 141–149 (1999). https://doi.org/10.1007/BF02490643
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02490643