Abstract
A thermistor transducer is described which has been designed for the detection of the carotid pulse. Dimensioning parameters are presented. The transducer is characterised by a superior signal-to-noise ratio which enables double differentiation and processing of the steep upstroke of the second derivative. For marking the termination of the ejection period, a newer criterion is defined, featuring advantages for automatic data acquisition. The almost undistorted reproduction of the initial phase of isotonic contraction (s.e.t. interval) is realised by suitable dimensioning of the transducer. Application of the transducer for measuring a modified pre-ejection interval p.e.p.* and the definition of the so-called pre-ejection index p.i. is given. The first clinical results demonstrate the possibility for the early detection of latent heart failure and revealing the effectiveness of glycoside administration.
Sommaire
L'article décrit un transducteur à thermistance qui a été conçu pour détecter les pulsations de la carotide, il présente aussi les paramètres des dimensions. Le transducteur est caractérise par un rapport signal/parasites supérieur permettant la différenciation double et le traitement du transport ascensionnel rapide de la seconde dérivée. Afin de marquer la terminaison de la période d'éjection, on a dèfini un nouveau critére dècrivant les avantages de recueillir automatiquement les donnèes. La reproduction presque sans distorsions de la phase intiale de la contraction isotonique (intervalles SET) est accomplie à l'aide d'un transducteur de dimensions convenables. On donne l'application du transducteur pour la mesure d'un intervalle pré-éjection modifié PEP* et la définition de l'index de pré-éjection ainsi nommè. Les premiers résultats cliniques démontrent la possibilité de détecter en temps voulu les arrêts cardiaques latents et de mettre en évidence l'efficacité de l'administration de glycoside.
Zusammenfassung
Ein Thermistor-Wandler wird beschrieben, der vorzugsweise zur Abnahme des Karotispulses geeignet ist. Der Wandler ist durch ein hohes Nutzsignal ausgezeichnet, das zweimalige Differentiation ermöglicht, womit der steile Pulseinsatz der zweiten Ableitung verarbeitet werden kann. Zur Kennzeichnung der Beendigung der Austreibung wird ein neues Kriterium angegeben, das Vorteile für die automatische Datenerfassung besitzt. Die nahezu unverzerrte Wiedergabe der initialen Phase der isotonischen Kontraktion (SET-interval) wird durch eine geeignete Dimensionierung des Wandlers gewährleistet. Die Anwendung des Wandlers zur Messung einer modifizierten Anspannungszeit PEP* und die Definition des sog. Anspannungsindex PI wird angegeben. Erste klinische Ergebnisse zeigen die Möglichkeit der Erkennung von Frühstadien der Herinsuffizienz sowie des Nachweises der Effektivität der Anwendung von Glykosiden.
Similar content being viewed by others
References
Ahmed, S. S. Levinson, G. E., Schwartz, C. J. andEttinger, Ph. O. (1972) Systolic time intervals as measures of the contractile state of the left ventricular myocardium in man.Circulation 46, 559–571.
Laughlin, D. E. andMahoney, R. P. (1972) New phonocardiographic transducers utilizing the hot-wire anemometer principle.Med. & Biol. Engng. 10, 43–55.
Rentsch, W. (1972) A thermistor pulse transducer: theoretical and practical aspects.10, 301–305.
Rentsch, W. (1973) Digital measurement of pre-ejection time intervals.Digest of the 10th international conference on Bio-medical engineering, Dresden.
Rentsch, W. (1975) Ein neuer nicht-invasiver Index zur Erkennung von Frühstadien der Herzinsuffizienz.Ztschr. Inn. Med. 30.
Siegel, J. H., Sonnenblick, E. H., Judge, E. D. andWilson, W. S. (1964) The quantification of myocardial contractility in dog and man.Cardiologia 45, 189–220.
Stafford, R. W., Harris, W. S. andWeissler, A. W. (1970) Left ventricular systolic time intervals as indices of postural circulatory stress in man.Circulation 41, 485–492.
Talley, R. C., Meyer, J. F. andMcNay, J. L. (1971) Evaluation of the pre-ejection period as an estimate of myocardial contractility in dogs.Am. J. Cardiol. 27, 384–391.
Urbaszek, W., Modersohn, D., Günther, K., Gmyrek, G. andBörner, P. (1974) Der Aussagewert ventrikeldruckbezogener und aortenflußabhängiger Kontraktilitätsparameter im Ganztierexperiment.Ztschr. Inn. Med. 29, 745–751.
Weissler, A. M., Harris, W. S. andSchoenfeld, C. D. (1968) Systolic time intervals in heart failure in man.Circulation 37, 149–159.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Rentsch, W. Improved thermistor transducer and its application for detection of latent heart failure. Med. & biol. Engng. 14, 130–135 (1976). https://doi.org/10.1007/BF02478738
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02478738