Abstract
A simple inexpensive bedside automatic ECG data-collection system is presented. The main parameter measured is the R-R interval length that can be used in the construction of a heart rate variability signal. Another parameter measured is the shape of the T-wave in the ECG signal. The collected data are transferred to a remote host computer through the public telephone network, by means of a modem. The system can function through the whole range of human heart rates. The described solution differs from most existing ones by utilising the existing ECG monitoring equipment in hospitals, which usually does not store any information. This equipment is connected by a portable, independent, special-purpose system to a remote host computer which can further analyse and store the data.
Similar content being viewed by others
References
Adam, D. R., Smith, J. M., Akselrod, S., Nyberg, S., Powell, A. D. andCohen, R. J. (1984) Fluctuations in T-wave morphology and susceptibility to ventricular fibrillation.J. Electrocardiol.,17, 209–218.
AHA Committee (1975) Recommendations for standardization of leads and of specifications for instruments in ECG and VCG.Circ.,52, July–Dec., 11–31.
Akselrod, S., Gordon, D., Ubel, F. A., Shannon, D. C., Barger, A. C. andCohen, R. J. (1981) Power spectrum analysis of heart rat fluctuation: a quantitative probe of beat to beat cardiovascular control.Science,213, 220–222.
Braunwald, E. (1980)Heart disease. A textbook of cardiovascular medicine. W. B. Saunders Company, Chap. 12, 447.
Ewing, D. J., Neilson, J. M. M. andTravis, P. (1984) New method for assessing cardiac parasympathetic activity using 24 hour electrocardiograms.Br. Heart J.,52, 396–402.
Friedman, H. (1971)Diagnostic electrocardiography and vector cardiography. McGraw-Hill, 64–77.
Friedmann, P. (1987) The development of a portable HRV analysis system. Technion-Israel Institute of Technology.
Hyndman, B. W. andGregory, J. R. (1975) Spectral analysis of sinus arrhythmia during mental loading.Ergonomics,18, 225–270.
Kleiger, R. E., Miller, J. P., Bigger, J. T., Moss, A. M. and the Multicenter Postinfarction Group (1984) Heart rate variability: a variable predicting montality following acute myocardial infarction.J. Coll. Cardiol.,3, 2.
MacFarlane, P. W. andLawrie, T. D. V. (1989)Comprehensive electrocardiology. Theory and practice in health and disease. Pergamon Press, Vol. 3, 1442.
Magid, N. M., Martin, G. J., Kehoe, R. F., Zheutlin, T. A., Eckberg, D. L., Myers, G. A., Barnett, P. S., Murray, E. A., Gonzales, S. K., Weiss, J. S., Leschi, M. andSinger, D. H. (1985) Diminished heart rate rate variability in sudden cardiac death.Circ.,72, 111–241 (abstract).
Merri, M., Farden, D. C., Mottley, J. G. andTitlebaum, E. L. (1990) Sampling frequency of the electrocardiogram for spectral analysis of the heart rate variability.IEEE Trans.,BME-37, 99–106.
Myers, G. A., Martin, G. J., Magid, N. M., Barnett, P. S., Schaad, J. W., Weiss, J. S., Lesch, M. andSinger, D. H. (1986) Power spectral analysis of heart rate variability in sudden cardiac death: comparison to other methods.,BME-33, 1149–1156.
Pomerantz, B., Macaulay, J. B., Caudill, M. A., Katz, I., Adam, D., Gordon, D., Kilborn, K. M., Barger, A. C., Shannon, D. C., Cohen, R. J. andBenson, H. (1985) Assessment of autonomic function in humans by heart rate spectral analysis.Am. J. Physiol.,248, (1), H151-H153.
Rompelman, O., Snijders, J. B. I. M. andVan Spronsen, C. J. (1982) The measurement of heart rate variability spectra with the help of a personal computer.IEEE Trans.,BME-29, 503–510.
Rosenbaum, M. B., Sicouri, S. J., Davidenko, J. M. andElizari, M. (1985) Heart rate and electrotonic modulation of the T-wave: a singular relationship. InCardiac electrophysiology and arrhythmias. Grune & Stratton Inc., 485–488.
Thakor, N. V., Webster, J. G. andTompkins, W. J. (1984) Estimation of QRS complex power spectra for design of a QRS filter.IEEE Trans.,MBE-31, 702–706.
Tompkins, W. J. (1985) Patient worn, intelligent arrhythmia systems.IEEE Eng. in Med. & Biol. Mag.,4, 38–42.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Friedmann, P., Adam, D. Portable system for acquisition and transmission of ECG parameters. Med. Biol. Eng. Comput. 30, 57–62 (1992). https://doi.org/10.1007/BF02446194
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02446194