Portable system for acquisition and transmission of ECG parameters

  • Instrumentation
  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

A simple inexpensive bedside automatic ECG data-collection system is presented. The main parameter measured is the R-R interval length that can be used in the construction of a heart rate variability signal. Another parameter measured is the shape of the T-wave in the ECG signal. The collected data are transferred to a remote host computer through the public telephone network, by means of a modem. The system can function through the whole range of human heart rates. The described solution differs from most existing ones by utilising the existing ECG monitoring equipment in hospitals, which usually does not store any information. This equipment is connected by a portable, independent, special-purpose system to a remote host computer which can further analyse and store the data.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Adam, D. R., Smith, J. M., Akselrod, S., Nyberg, S., Powell, A. D. andCohen, R. J. (1984) Fluctuations in T-wave morphology and susceptibility to ventricular fibrillation.J. Electrocardiol.,17, 209–218.

    Google Scholar 

  • AHA Committee (1975) Recommendations for standardization of leads and of specifications for instruments in ECG and VCG.Circ.,52, July–Dec., 11–31.

    Google Scholar 

  • Akselrod, S., Gordon, D., Ubel, F. A., Shannon, D. C., Barger, A. C. andCohen, R. J. (1981) Power spectrum analysis of heart rat fluctuation: a quantitative probe of beat to beat cardiovascular control.Science,213, 220–222.

    Google Scholar 

  • Braunwald, E. (1980)Heart disease. A textbook of cardiovascular medicine. W. B. Saunders Company, Chap. 12, 447.

  • Ewing, D. J., Neilson, J. M. M. andTravis, P. (1984) New method for assessing cardiac parasympathetic activity using 24 hour electrocardiograms.Br. Heart J.,52, 396–402.

    Google Scholar 

  • Friedman, H. (1971)Diagnostic electrocardiography and vector cardiography. McGraw-Hill, 64–77.

  • Friedmann, P. (1987) The development of a portable HRV analysis system. Technion-Israel Institute of Technology.

  • Hyndman, B. W. andGregory, J. R. (1975) Spectral analysis of sinus arrhythmia during mental loading.Ergonomics,18, 225–270.

    Google Scholar 

  • Kleiger, R. E., Miller, J. P., Bigger, J. T., Moss, A. M. and the Multicenter Postinfarction Group (1984) Heart rate variability: a variable predicting montality following acute myocardial infarction.J. Coll. Cardiol.,3, 2.

    Google Scholar 

  • MacFarlane, P. W. andLawrie, T. D. V. (1989)Comprehensive electrocardiology. Theory and practice in health and disease. Pergamon Press, Vol. 3, 1442.

  • Magid, N. M., Martin, G. J., Kehoe, R. F., Zheutlin, T. A., Eckberg, D. L., Myers, G. A., Barnett, P. S., Murray, E. A., Gonzales, S. K., Weiss, J. S., Leschi, M. andSinger, D. H. (1985) Diminished heart rate rate variability in sudden cardiac death.Circ.,72, 111–241 (abstract).

    Google Scholar 

  • Merri, M., Farden, D. C., Mottley, J. G. andTitlebaum, E. L. (1990) Sampling frequency of the electrocardiogram for spectral analysis of the heart rate variability.IEEE Trans.,BME-37, 99–106.

    Google Scholar 

  • Myers, G. A., Martin, G. J., Magid, N. M., Barnett, P. S., Schaad, J. W., Weiss, J. S., Lesch, M. andSinger, D. H. (1986) Power spectral analysis of heart rate variability in sudden cardiac death: comparison to other methods.,BME-33, 1149–1156.

    Google Scholar 

  • Pomerantz, B., Macaulay, J. B., Caudill, M. A., Katz, I., Adam, D., Gordon, D., Kilborn, K. M., Barger, A. C., Shannon, D. C., Cohen, R. J. andBenson, H. (1985) Assessment of autonomic function in humans by heart rate spectral analysis.Am. J. Physiol.,248, (1), H151-H153.

    Google Scholar 

  • Rompelman, O., Snijders, J. B. I. M. andVan Spronsen, C. J. (1982) The measurement of heart rate variability spectra with the help of a personal computer.IEEE Trans.,BME-29, 503–510.

    Google Scholar 

  • Rosenbaum, M. B., Sicouri, S. J., Davidenko, J. M. andElizari, M. (1985) Heart rate and electrotonic modulation of the T-wave: a singular relationship. InCardiac electrophysiology and arrhythmias. Grune & Stratton Inc., 485–488.

  • Thakor, N. V., Webster, J. G. andTompkins, W. J. (1984) Estimation of QRS complex power spectra for design of a QRS filter.IEEE Trans.,MBE-31, 702–706.

    Google Scholar 

  • Tompkins, W. J. (1985) Patient worn, intelligent arrhythmia systems.IEEE Eng. in Med. & Biol. Mag.,4, 38–42.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Friedmann, P., Adam, D. Portable system for acquisition and transmission of ECG parameters. Med. Biol. Eng. Comput. 30, 57–62 (1992). https://doi.org/10.1007/BF02446194

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02446194

Keywords

Navigation