Abstract
The pulsed surface muon beam of the Rutherford Appleton Laboratory is well suited to performing μSR measurements in zero and low magnetic fields with the longitudinal set-up. In this paper we describe our data analysis procedure and the effect of the collimation on the spectra. The determination of the efficiency ratio of the telescopes is discussed. We point out that for some measurements it is important to take into account the muon beam structure properly.
Similar content being viewed by others
References
G.H. Eaton, A. Carne, S.F.J. Cox, J.D. Davies, R. De Renzi, O. Hartmann, A. Kratzer, C. Ristori, C.A. Scott, G.C. Stirling and T. Sunquist, Nucl. Instr. Meth. A269 (1988) 483.
A.I. Borden, A. Carne, M. Clarke-Gayther, G.H. Eaton, H.J. Jones, G. Thomas, O. Hartmann and T. Sundqvist, Nucl. Inst. Methods in Physics Research A292 (1990) 21: see also a. Carne, S.F.J. Cox, G.H. Eaton and C.A. Scott, Hyp. Int. 65 (1990) 1175.
R.S. Hayano, Y.J. Uemura, J. Imazato, N. Nishida, T. Yamazaki and R. Kubo, Phys. Rev. B 20 (1979) 850.
P. Dalmas de Réotier, J.P. Sanchez, P. Vulliet, A. Yaouanc, S. Harris, O. Hartmann, E. Karlsson, R. Wäppling, B. Barbara, B. Gorges, R. Lemaire, A. Weidinger and P.C.M. Gubbens, Hyp. Int. 64 (1990) 389.
R. Kadono, J. Imazato, T. Matsuzaki, K. Nishiyama, K. Nagamine and T. Yamazaki, Phys. Rev. B39 (1989) 23.
P. Dalmas de Réotier, J.P. Sanchez, A. Yaouanc, B. Chevalier, P. Chaudouët and R. Madar, Hyp. Int. 64 (1990) 457.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Dalmas de Réotier, P., Yaouanc, A., Eaton, G.H. et al. Positive muon data analysis at ISIS. Hyperfine Interact 65, 1113–1119 (1991). https://doi.org/10.1007/BF02397769
Issue Date: