Effect of construction methods on the magnitude of forces on thin single-anchor retaining walls

  • Discussions
  • Published:
Hydrotechnical Construction Aims and scope

Conclusions

  1. 1.

    Forces in flexible wall anchors depend on the method of construction. When constructing such walls, it should be borne in mind that changing the designed procedure of construction can cause dangerous overstresses in the anchor fastenings and unloading of the span part of the wall.

  2. 2.

    In case a change in the designed sequence of the wall construction is unavoidable (i.e., when carrying out a subsequent excavation) it is necessary to increase the sections of the anchor rods, distributing beams, and bolt connections. At the same time, if there is confidence in the rigidity of the anchor suports (of the girders, wall anchors, pile “framing,” etc.) one should redesign the sheet piles substituting a lighter section.

  3. 3.

    The results obtained in the studies should be taken into account when designing wall elements with rigid anchor fastenings by introducing coefficients for the change in magitude of the maximum bending moments in the span and of the anchor forces.

Based on an analysis of the results of these studies, the following coefficients are proposed as preliminary recommendations: a) for the reduction of moment in the span of a flexible wall, ξd = 0.8–09; b) for increase of active anchor force, the coefficient αd = 1.35–1.5. Increases of the forces in walls without subsequent excavation can be determined according to earlier published studies by the authors. It is recommended that the smallest value of the coefficient ξd and the greatest value of αd be used for a very firm, rigid anchor support and short anchor rods.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Authors

Additional information

For the begining and continuation of the discussion, see “Gidrotekhnicheskoe Stroitel'stvo,” 1966, No. 1, pp. 41–44; No. 3, pp. 44–46; No. 5, pp. 41–45; No. 7, pp. 52–53, 1967, No. 1, pp. 39–44; No. 3, pp. 47–50 and No. 4, pp. 39–41.

Translated from Gidrotekhnicheskoe Stroitel'stvo, No. 5, pp. 47–49, May, 1967.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lazebnik, G.E., Chernysheva, E.I. Effect of construction methods on the magnitude of forces on thin single-anchor retaining walls. Hydrotechnical Construction 1, 472–474 (1967). https://doi.org/10.1007/BF02382698

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02382698

Keywords

Navigation