Abstract
Biomedical engineering inputs have been important in the design, development and testing of substitute heart valves as well as in the pre- and post-operative management of patients with cardiac valve disease. This paper is a review of heart valve replacement whose goal is the enhancement of future bioengineering contributions. We review the approach to the patient with valvular heart disease, and the sources of early and late postoperative pathology with emphasis on complications of the prostheses used. Major significant problem areas relate to the noninvasive evaluation of cardiovascular function (both before and after surgery), device design, hemodynamics, and the need for thromboresistant and durable materials.
Similar content being viewed by others
References
Ahmad, R., S.M. Manohitharajah, P.B. Deverall, and D.A. Watson. Chronic hemolysis following mitral valve replacement. A comparative study of the Bjork-Shiley, composite-seat Starr-Edwards, and framemounted aortic homograft valves.J. Thorac. Cardiovasc. Surg. 71:212–217, 1976.
Alam, M., S. Goldstein, and J.B. Lakier. Echocardiographic changes in the thickness of porcine valves with time.Chest 79:663–668, 1981.
American Heart Association.Heart Facts: 1982. American Heart Association (publishers), 1981, 25 pp.
Anderson, D.J., B.H. Bulkley, and G.M. Hutchins. A clinicopathologic study of prosthetic valve endocarditis in 22 patients: Morphologic basis for diagnosis and therapy.Am. Heart J. 94:325–332, 1977.
Andrade, J.D., D.L. Coleman, P. Didisheim, S.R. Hanson, R. Mason, and E. Merrill. Blood-materials interactions — 20 years of frustration.Trans. Am. Soc. Artif. Intern. Organs. 27: 659–662, 1981.
Angell, W.W. and J.D. Angell. Porcine valves.Prog. Cardiovasc. Dis. 23:141–166, 1980.
Angell, W.W., J.D. Angell, and A. Sywak. The Angell-Shiley porcine xenograft.Ann. Thorac. Surg. 28:537–553, 1978.
Arnett, E.N. and W.C. Roberts. Prosthetic valve endocarditis. Clinicopathologic analysis of 22 necropsy patients with comparison of observations in 74 necropsy patients with active infective endocarditis involving natural left-sided cardiac valves.Am. J. Cardiol. 38:281–292, 1976.
Arrigoni, M.G., J.R. Pluth, G.K. Danielson, and J.L. Titus. Stuck aortic poppet. A hazard of close-clearance cloth-covered prosthetic aortic valves.J. Am. Med. Assoc. 219:183–185, 1972.
Baier, R.E. Key events in blood interactions at non-physiologic interfaces — A personal primer.Artif. Organs 2:422–426, 1978.
Berndt, T., D. Goodman, and R. Popp. Echocardiographic and phonocardiographic confirmation of suspected caged mitral valve malfunction.Chest 70:221–230, 1976.
Bernstein, E.F. Certain aspects of blood interfacial phenomena — Red blood cells.Fed. Proc. Fed. Am. Soc. Exp. Biol. 30:1510–1515, 1971.
Bjork, V.O. and A. Henze. Ten years' experience with the Bjork — Shiley tilting disc valve.J. Thorac. Cardiovasc. Surg. 78:331–342, 1979.
Blackshear, P.L. Mechanical hemolysis in flowing blood. In:Biomechanics: Its Foundations and Objectives, edited by Y.C. Fung, N. Perrone, and M. Anliker. Englewood Cliffs, New Jersey: Prentice Hall, 1972, pp. 501–528.
Blackstone, E.H., J.W. Kirklin, J.R. Pluth, M.E. Turner, and G.V.S. Parr. The performance of the Braunwald-Cutter aortic prosthetic valve.Ann. Thorac. Surg. 23:302–318, 1977.
Bokros, J.C., L.D. LaGrange, and F.J. Schoen. Control of structure of carbon for use in bioengineering. In:Chemistry and Physics of Carbon, Vol. 9, edited by P.L. Walker. New York: Marcel Dekker, 1973, pp. 103–171.
Bonchek, L.I. and A. Starr. Ball valve prostheses: Current appraisal of late results.Am. J. Cardiol. 35:843–854, 1975.
Borow, K.M., L.H. Green, T. Mann, L.J. Sloss, E. Braunwald, J.J. Collins, Jr., L. Cohn, and W. Grossman. End-systolic volume as a predictor of postoperative left ventricular performance in volume overload from valvular regurgitation.Am. J. Med. 68:655–663, 1980.
Bowen, T.E., R. Zajtchuk, W.H. Brott, and C.M. deCastro. Isolated mitral valve replacement with the Kay-Shiley prosthesis. Long-term follow-up and recommendations.J. Thorac. Cardiovasc. Surg. 80:45–49, 1980.
Brais, M.P. and N.S. Braunwald. Tissue acceptance of materials implanted within the circulatory system.Arch. Surg. 109:351–358, 1974.
Brodie, B., W. Grossman, L. McLaurin, P.J.K. Starek, and E. Craige. Diagnosis of prosthetic mitral valve malfunction with combined echo-phonocardiography.Circulation 53:93–100, 1976.
Buch, W.S., R.D. Pipkin, W.D. Hancock, and T.J. Fogarty. Mitral valve replacement with the Hancock stabilized glutaraldehyde valve. Clinical and laboratory evaluation.Arch. Surg. 110:1408–1415, 1975.
Byrne, J.P., D.M. Behrendt, M.M. Kirsh, and M.B. Orringer. Replacement of heart valves by prosthetic devices. In:Pathobiology Annual, Vol. 7, edited by H.L. Ioachim, New York: Appleton-Century-Crofts, 1977, pp. 83–114.
Carabello, B.A., L.H. Green, W. Grossman, L.H. Cohn, J.K. Koster, and J.J. Collins, Jr. Hemodynamic determinants of prognosis of aortic valve replacement in critical aortic stenosis and advanced congestive heart failure.Circulation 62:42–48, 1980.
Carpentier, A., A. Deloche, J. Relland, J.N. Fabiani, J. Forman, J.P. Camilleri, R. Soyer, and Ch. Dubost. Six-year follow-up of glutaraldehyde-preserved heterografts.J. Thorac. Cardiovasc. Surg. 68:771–782, 1974.
Clark, R.E., T.A. Pavolovic, B.E. Knight, J.H. Joist, S.D. Burrows, R.C. McKnight, and E.B. Brown. Quantification of wear, hemolysis and coagulation deficits in patients with Beall mitral valves.Circulation 56(Suppl. 2):II-139–II-143, 1979.
Clark, R.E., W.M. Swanson, J.L. Kardos, R.W. Hagen, and R.A. Beauchamp. Durability of prosthetic heart valves.Ann. Thorac. Surg. 26:323–334, 1978.
Cohn, L.H., J.K. Koster, R.B. Mee, and J.J. Collins, Jr. Long-term follow-up of the Hancock bioprosthetic heart valve. A six-year review.Circulation 60(Suppl. 2):II-139–II-143, 1979.
Cohn, L.H., J.H. Mudge, F. Pratter, and J.J. Collins, Jr. Five to eight-year follow-up of patients under-going porcine heart-valve replacement.N. Engl. J. Med. 304:258–262, 1981.
Cohn, L.H., J.H. Sanders, and J.J. Collins, Jr. Actuarial comparison of Hancock porcine and prosthetic disc valves for isolated mitral valve replacement.Circulation 54(Suppl. 3):III-60–III-63, 1976.
Colapinto, N.D. and M.D. Silver. Prosthetic heart valve replacement: Causes of early postoperative death.J. Thorac. Cardiovasc. Surg. 61:938–944, 1971.
Crexells, C., N. Aerichide, Y. Bonny, G. LePage, and L. Campeau. Factors influencing hemolysis in valve prostheses.Am. Heart J. 84:161–170, 1972.
Cunha, C.L.P., E.R. Guiliani, J.A. Callahan, and J.R. Pluth. Echophonocardiographic findings in patients with prosthetic heart valve malfunction.Mayo Clin. Proc. 55:231–242, 1980.
Davila, J.S., D.J. Magilligan, and J.W. Lewis. Is the Hancock porcine valve the best cardiac valve substitute today?Ann. Thorac. Surg. 26:303–315, 1978.
Dunn, J.M. Porcine valve durability in children.Ann. Thorac. Surg. 32:357–366, 1981.
Duvoisin, G.E., R.O. Brandenburg, and D.C. McGoon. Factors affecting thromboembolism associated with prosthetic heart valves.Circulation 35(Suppl. 1):I-70–I-76, 1967.
Elek, S.D., and P.E. Conen. The virulence ofStaphylococcus pyogenes for man. A study of the problems of wound infection.Br. J. Exp. Pathol. 38:573–586, 1957.
Emery, R.W., and D.M. Nicoloff. St. Jude Medical cardiac valve prosthesis: In vitro studies.J. Thorac. Cardiovasc. Surg. 78:269–276, 1979.
English, T.A.H., and B.B. Milstein. Repeat open intracardiac operation; analysis of 50 operations.J. Thorac. Cardiovasc. Surg. 76:56–60, 1978.
Ferrans, V.J., S.W. Boyce, M.E. Billingham, T.L. Spray, and W.C. Roberts. Infection of glutaraldehyde-preserved porcine valve heterografts.Am. J. Cardiol. 43:1123–1135, 1979.
Ferrans, V.J., S.W. Boyce, M.E. Billingham, J. Jones, T. Ishihara, and W.C. Roberts. Calcific deposits in porcine bioprostheses: Structure and pathogenesis.Am. J. Cardiol. 46:721–734, 1980.
Ferrans, V.J., T.L. Spray, M.E. Billingham, and W.C. Roberts. Structural changes in glutaraldehydetreated porcine heterografts used as substitute cardiac valves. Transmission and scanning electron microscopic observations in 12 patients.Am. J. Cardiol. 41:1159–1184, 1978.
Fishbein, M.C., S.A. Gissen, J.J. Collins, E.M. Barsamian, and L.H. Cohn. Pathologic findings after cardiac valve replacement with glutaraldehyde-fixed porcine valves.Am. J. Cardiol. 40:331–337, 1977.
Fishbein, M.C., W.C. Roberts, A. Golden, and C.A. Hufnagel. Cardiac pathology after aortic valve replacement using Hufnagel trileaflet prostheses: A study of 20 necropsy patients.Am. Heart J. 89:443–448, 1975.
Forfat, J.C. A 7-year analysis of hemorrhage in patients on long-term anticoagulant treatment.Br. Heart J. 35:128–132, 1979.
Frank, S., A. Johnson, and J. Ross. Natural history of valvular aortic stenosis.Br. Heart J. 35:41–46, 1973.
Fry, D.L. Acute vascular endothelial changes associated with increased blood velocity gradients.Circ. Res. 22:165–197, 1968.
Fry, D.L. Certain histological and chemical responses of the vascular interface to acutely induced mechanical stress in the aorta of the dog.Circ. Res. 24:93–108, 1969.
Fuster, V. and J.H. Chesebro. Antithrombotic therapy: Role of platelet-inhibitor drugs. I. Current concepts of thrombogenesis: Role of platelets.Mayo. Clin. Proc. 56:102–112, 1981.
Fuster, V. and J.H. Chesebro. Antithrombotic therapy: Role of platelet-inhibitor drugs. III. Management of arterial thromboembolic and atherosclerotic disease.Mayo. Clin. Proc. 56:265–273, 1981.
Gabbay, S., D.M. McQueen, E.L. Yellin, and R.W.M. Frater. In vitro hydrodynamic comparison of mitral valve bioprostheses.Circulation 60(Suppl. 1):I-62–I-70, 1979.
Geraci, J.E., A.J.D. Dale, and D.C. McGoon. Bacterial endocarditis and endarteritis following cardiac operations.Wis. Med. J. 62:302–315, 1963.
Goldman, M.R., C.a. Boucher, P.C. Block, M.J. Buckley, W.G. Austen, H.W. Strauss, and G.M. Pohost. Spectrum of congestive heart failure late after aortic valve or mitral replacement: Differentiation of valvular versus myocardial cause by radionuclide ventriculogram-ejection fraction.Am. Heart J. 102:751–756, 1981.
Gorlin, R. and S.G. Gorlin. Hydraulic formula for calculation of the area of the stenotic mitral valve, other cardiac valves, and central circulatory shunts. I.Am. Heart J. 41:1–29, 1951.
Griffiths, S.P., B.M. Zazula, D. Courtney, F.C. Spencer, and J.R. Malm. Trends in cardiovascular surgery (1961–1977): Review of the New York City and State experience.Am. J. Cardiol. 44:555–562, 1979.
Grossman, W. Cardiac hypertrophy: Useful adaptation or pathologic process?Am. J. Med. 69:576–584, 1980.
Grossman, W.Cardiac Catheterization and Angiography, 2nd edition. Philadelphia, PA: Lea and Febiger, 1980.
Harken, D.E., H.S. Soroff, W.J. Taylor, A.A. Lefemine, S.K. Gupta, and S. Lunzer. Partial and complete prostheses in aortic insufficiency.J. Thorac. Cardiovasc. Surg. 40:744–762, 1960.
Harrison, E.C., E.J. Roschke, H.I. Meyers, W.A. Edmiston, L.S. Chan, D. Tatter, and F.K. Lau. Cholelithiasis: A frequent complication of artificial heart valve replacement.Am. Heart J. 95:483–488, 1978.
Henry, W.L., R.O. Bonow, J.S. Borer, J.H. Ware, K.M. Kent, D.R. Redwood, C.L. McIntosh, A.G. Morrow, and S.E. Epstein. Observations on the optimum time for operative intervention for aortic regurgitation. I. Evaluation of the results of aortic valve replacement in symptomatic patients.Circulation 61:471–483, 1980.
Henry, W.L., R.O. Bonow, J.S. Borer, K.M. Kent, J.H. Ware, D.R. Redwood, S.M. Itscoitz, C.L. McIntosh, A.G. Morrow, and S.E. Epstein. Evaluation of aortic valve replacement in patients with valvular aortic stenosis.Circulation 61:814–825, 1980.
Hunter, G. and D. Dandy. The natural history of the patient with an infected total hip replacement.J. Bone Jt. Surg., Br. Vol. 59B:293–297, 1977.
Hylen, J.C., R.P. Hodam, and F.E. Kloster. Changes in the durability of silicone rubber in ball-valve prostheses.Ann. Thorac. Surg. 13:324–329, 1972.
Hylen, J.C., F.E. Koster, R.H. Herr, P.Q. Hull, A.W. Ames, A. Starr, and H.E. Griswold. Phonocardiographic diagnosis of aortic ball variance.Circulation 38:90–102, 1968.
Hylen, J.C., F.E. Kloster, A. Starr, and H.E. Griswold. Aortic ball variance: Diagnosis and treatment.Ann. Intern. Med. 72:1–8, 1970.
Ionescu, M.I., A.P. Tandon, D.A.S. Mary, and A. Abid. Heart valve replacement with the Ionescu-Shiley pericardial xenograft.J. Thorac. Cardiovasc. Surg. 73:31–42, 1977.
Ishihara, T., V.J. Ferrans, S.W. Boyce, M. Jones, and W.C. Roberts. Structure and classification of cuspal tears and perforations in procine bioprosthetic cardiac valves implanted in patients.Am. J. Cardiol. 48:665–678, 1981.
Isom, O.W., F.C. Spencer, E. Glassman, P. Teiko, A.D. Boyd, J.N. Cunningham, and G.E. Reed. Long-term results in 1375 patients undergoing valve replacement with the Starr-Edwards cloth-covered steel ball prosthesis.Ann. Surg. 186:310–322, 1977.
Joassin, A. and J.E. Edwards. Causes of death within 30 days of mitral valvular replacement: Analysis of 36 cases.Cardiovasc. Clin. 5:169–184, 1973.
Joassin, A and J.E. Edwards. Late causes of death after mitral valve replacement: Analysis of 36 cases.J. Thorac. Cardiovasc. Surg. 65:225–263, 1973.
Kaae, J.L. Structure and mechanical properties of isotropic pyrolytic carbons deposited below 1600°C.J. Nucl. Mater. 38:42–50, 1971.
Karp, R.B., R.J. Cyrus, E.H. Blackstone, J.W. Kirklin, N.T. Kouchoukos, and A.D. Pacifico. The Bjork-Shiley valve. Intermediate-term follow-up.J. Thorac. Cardiovasc. Surg. 81:602–614, 1981.
Kaster, R.L., C.W. Lillehei, and P.J.K. Starek. The Lillehei-Kaster pivoting disc aortic prosthesis and a comparative study of its pulsatile flow characteristics with four other prostheses.Trans. Am. Soc. Artif. Intern. Organs. 16:233–243, 1970.
Kirklin, J.W. and A.D. Pacifico. Surgery for acquired valvular heart disease.N. Engl. J. Med. 288: 133–140, 194–198, 1973.
Lakier, J.B., F. Khaja, D.J. Magilligan, Jr., and S. Goldstein. Porcine xenograft valves. Long-term (60–89-month) follow-up.Circulation 62:313–318, 1980.
Lepley, D., R.J. Flemma, D.C. Mullen, H. Singh, and S. Chkravarty. Late evaluation of patients undergoing valve replacement with the Bjork-Shiley prosthesis.Ann. Thorac. Surg. 24:131–139, 1977.
Levy, R.J. The pathogenesis of porcine xenograft valve calcification. In:Biomedical Polymers, Metals and Ceramics, edited by M. Szycher et al. Westport, Connecticut: Technomic Publishing Co., In press, 1982.
Liekweg, W.G., S.A. Levinson, and L.J. Greenfield. Infection of vascular grafts: incidence, anatomic location, etiologic agents, morbidity and mortality. In:Infections of Prosthetic Heart Valves and Vascular Grafts: Prevention, Diagnosis and Treatment, edited by R.J. Duma. Baltimore, Maryland: University Park Press, 1977, pp. 239–250.
Lindsay, R.M., R.G. Mason, S.W. Kim, J.D. Andrade, and R.M. Hakim. Blood surface interactions.Trans. Am. Soc. Artif. Intern. Organs 26:603–610, 1980.
Lipson, L.C., K.M. Kent, D.R. Rosing, R.O. Bonow, C.L. McIntosh, J. Condit, S.E. Epstein, and A.G. Morrow. Long-term hemodynamic assessment of the porcine heterograft in the mitral position. Late development of valvular stenosis.Circulation 64:397–402, 1981.
Macmanus, W., G. Grunkemeier, L. Housman, C. Maloney, B. Harlan, L. Lambert, and A. Starr. Early results with composite strut caged ball prostheses.Am. J. Cardiol. 46: 566–569, 1980.
Maddox, D.E., J. Wynne, R. Uren, J.A. Parker, J. Idoine, L.C. Siegel, J.M. Neill, P.F. Cohn, and B.L. Holman. Regional ejection fraction: A quantitative radionuclide index of regional left ventricular performance.Circulation 59:1001–1009, 1979.
Maron, B.J., V.J. Ferrans, and W.C. Roberts. Myocardial ultrastructure in patients with chronic aortic valve disease.Am. J. Cardiol. 35:725–739, 1975.
Mason, R.G., D. Sharp, H.Y.K. Chuang, and S.F. Mohammad. The endothelium: Roles in thrombosis and hemostasis.Arch. Pathol. Lab. Med. 101:61–64, 1977.
Nichols, H.T., J. Fernandez, D. Morse, and A.S. Gooch. Improved results in 336 patients with isolated mitral Beall valve replacement.Chest 62:266–272, 1972.
Olanoff, L.S., J.M. Anderson, and R.D. Jones. Sustained release of gentamicin from prosthetic heart valves.Trans. Am. Soc. Artif. Intern. Organs 25:334–338, 1979.
Oyer, P.E., E.B. Stinson, R.B. Griepp, and N.E. Shumway. Valve replacement with the Starr-Edwards and Hancock prostheses: Comparative analysis of late morbidity and mortality.Ann. Surg. 186:301–309, 1977.
Oyer, P.E., E.B. Stinson, B.A. Reitz, D.C. Miller, S.J. Rossiter, and N.E. Shumway. Long-term evaluation of the porcine xenograft bioprosthesis.J. Thorac. Cardiovasc. Surg. 78:343–350, 1979.
Pfeifer, J., N. Goldschlager, T. Sweatmen, F. Gerbode, and A. Selzer. Malfunction of mitral valve prosthesis due to thrombosis.Am. J. Cardiol. 29:95–99, 1972.
Pipkin, R.D., W.S. Buch, and T.J. Fogarty. Evaluation of aortic valve replacement with a porcine xenograft without long-term anticoagulation.J. Thorac. Cardiovasc. Surg. 71:179–186, 1976.
Pumphrey, C.W. and J. Dawes. Elevation of plasma β-thromboglobulin in patients with prosthetic cardiac valves.Thromb. Res. 22:147–155, 1981.
Rae, T. Localized tissue infection and the influence of foreign bodies. In:Fundamental Aspects of Biocompatibility, Vol. II, edited by D.F. Williams. Boca Raton, Florida: CRC Press, 1981, pp. 139–158.
Rahimtoola, S.H. The problem of prosthesis-patient mismatch.Circulation 58:20–24, 1978.
Rapaport, E. Natural history of aortic and mitral valve disease.Am. J. Cardiol. 35:221–227, 1975.
Richardson, J.V., N.T. Kouchoukos, J.O. Wright, and R.B. Karp. Combined aortic valve replacement and myocardial revascularization: Results in 220 patients.Circulation 59:75–81, 1979.
Roberts, W.C. Factors determining outcome of cardiac valve replacement.Ann. Thorac. Surg. 27:101–103, 1979.
Roberts, W.C. Complications of cardiac valve replacement: Characteristic abnormalities of prostheses pertaining to any or specific site.Am. Heart J. 103:113–122, 1982.
Roberts, W.C., B.H. Bulkley, and A.G. Morrow. Pathologic anatomy of cardiac valve replacement: A study of 224 necropsy patients.Prog. Cardiovasc. Dis. 15:539–587, 1973.
Roberts, W.C., M.C. Fishbein, and A. Golden. Cardiac pathology after valve replacement by disk prosthesis. A study of 61 necropsy patients.Am. J. Cardiol. 35:740–760, 1975.
Roberts, W.C. and W.J. Hammer. Cardiac pathology after valve replacement with a tilting-disk prosthesis (Bjork-Shiley type): A study of 46 necropsy patients and 49 Bjork-Shiley próstheses.Am. J. Cardiol. 37:1024–1033, 1976.
Roberts, W.C. and A.G. Morrow. Renal hemosiderosis in patients with prosthetic heart valves.Circulation 33:390–398, 1966.
Robinson, M.J., F.J. Hildner, and J.J. Greenberg. Disc variance of Beall mitral valve.Ann. Thorac. Surg. 11:11–17, 1971.
Roe, B.B., N.H. Fishman, J.C. Hutchins, and S.H. Goodenough. Occluder disruption of Wada-Cutter valve prosthesis.Ann. Thorac. Surg. 20:256–264, 1975.
Roschke, E.J. An engineer's view of prosthetic heart valve performance.Biomater. Med. Devices Artif. Organs 1:249–290, 1973.
Roschke, E.J. and E.C. Harrison. Size comparisons of commercial prosthetic heart valves.Med. Instrum. 7:277–282, 1973.
Roschke, E.J. and E.C. Harrison. Fluid shear stress in prosthetic heart valves.J. Biomech. 10: 299–314, 1977.
Rossiter, S.J., D.C. Miller, E.B. Stinson, P.E. Oyer, B.A. Reitz, and N.E. Shumway. Aortic and mitral prosthetic valve reoperations: Early and late results.Arch. Surg. 114:1279–1283, 1979.
Rossiter, S.J., E.B. Stinson, P.E. Oyer, D.C. Muller, J.N. Schapira, R.P. Martin, and N.E. Shumway. Prosthetic valve endocarditis: A comparison of heterograft tissue valves and mechanical valves.J. Thorac. Cardiovasc. Surg. 76:795–802, 1980.
Russell, F.B., D.M. Lederman, P.I. Singh, R.D. Cumming, R.A. Morgan, F.H. Levine, W.G. Austen, and M.J. Buckley. Development of seamless tri-leaflet valves.Trans. Am. Soc. Artif. Intern. Organs 26:66–71, 1980.
Salzman, E.W. Non-thrombogenic surfaces: Critical review.Blood 38:509–523, 1971.
Salzman, E.W. Blood-material interaction lecture. In: Devices and Technology Branch Contractors' Meeting Proceedings 1979. NIH Publication No. 81-2022. Bethesda, Maryland: Division of Heart and Vascular Disease, National Heart, Lung, and Blood Institute, 1980, pp. 23–27.
Sanders, S.P., R.J. Levy, M.D. Freed, W.I. Norwood, and A.R. Castaneda. Use of Hancock porcine xenografts in children and adolescents.Am. J. Cardiol. 46:429–438, 1980.
Sands, M., C. Leach, A. Lachman, and H. Levine. Thrombosis of the Bjork-Shiley aortic valve prosthesis.J. Am. Med. Assoc. 240:1411–1413, 1978.
Sandza, J.G., R.E. Clark, T.B. Ferguson, J.P. Connors, and C.S. Weldon. Replacement of prosthetic heart valves.J. Thorac. Cardiovasc. Surg. 74:864–874, 1977.
Santinga, J.T., J.T. Batsakis, J.D. Flora, and M.M. Kirsh. Hemolysis in the aortic prosthetic valve.Chest 69:556–561, 1976.
Schoen, F.J. Carbons in heart valve prostheses: Foundations and clinical performance. In:Biomedical Polymers, Metals and Ceramics, edited by M. Szycher et al. Westport, Connecticut: Technomic Publishing Co., 1982. In press.
Schoen, F.J. and N.S. Braunwald. Long-term morphology of tissue ingrowth on explanted human clothcovered prosthetic heart valves. Abstract.Trans. Soc. Biomater. (in press).
Schoen, F.J., J.J. Collins, Jr., and L.H. Cohn. Long-term failure rate and morphologic correlations in porcine bioprosthetic heart valves.Am. J. Cardiol. (in press).
Schoen, F.J., J.L. Titus, and G.M. Lawrie. Autopsy-determined causes of death after cardiac valve replacement.J. Am. Med. Assoc. (in press).
Schoen, F.J., J.L. Titus, and G.M. Lawrie. Materials degeneration causing late failure of mechanical heart valve prostheses: Problems and promise. In: Implant Retrieval: Material and Biological Analysis, edited by A. Weinstin, D. Gibbons, S. Brown, and W. Ruff. National Bureau of Standards, Special Publication 601. Gaithersburg, MD: National Bureau of Standards, 1981, pp. 269–282.
Selzer, A. and K.E. Cohn. Natural history of mitral stenosis: A review.Circulation 45:878–890, 1972.
Shah, A., M. Dolgin, D.A. Tice, and N. Trehan. Complications due to cloth wear in cloth-covered Starr-Edwards aortic and mitral valve prosthesis-and their management.Am. Heart J. 96:407–414, 1978.
Shemin, R.J., V.A. Guadiani, D.M. Conkle, and A.G. Morrow. Prosthetic aortic valves. Indications for and results of reoperation.Arch. Surg. 114:63–65, 1979.
Shepherd, J.T. and P.M. Vanhoutte.The Human Cardiovascular System. Facts and Concepts. New York: Raven Press, 1979, p. 325.
Shim, H.S. The behavior of isotropic pyrolytic carbons under cyclic loading.Biomater. Med. Devices Artif. Organs 2:55–65, 1974.
Shim, H.S. and F.J. Schoen. The wear resistance of pure and silicon-alloyed isotropic carbons.Biomater. Med. Devices Artif. Organs 2:103–118, 1974.
Sigwart, U., H. Schmidt, U. Gleichmann, and H.G. Borst.In vivo evaluation of the Lillehei-Kaster heart valve prosthesis.Ann. Thorac. Surg. 22:213–220, 1976.
Silver, M.D. Wear in Bjork-Shiley heart valve prostheses recovered at necropsy or operation.J. Thorac. Cardiovasc. Surg. 79:693–699, 1980.
Silver, M.D., B.N. Datta, and F.V. Bowes. A key to identify heart valve prostheses.Arch. Pathol. 99:132–138, 1975.
Silver, M.D. and G.J. Wilson. The pathology of wear in the Beall model 104 heart valve prosthesis.Circulation 56:617–622, 1977.
Smithwick, W., N.T. Kouchoukos, R.B. Karp, A.D. Pacifico, and J.W. Kirklin. Late stenosis of Starr-Edwards cloth-covered prostheses.Ann. Thorac. Surg. 20:249–254, 1975.
Spray, T.L. and W.C. Roberts. Structural changes in porcine xenografts used as substitute cardiac valves. Gross and histologic observations in 51 glutaraldehyde-preserved Hancock valves in 41 patients.Am. J. Cardiol. 40:319–330, 1977.
Starek, P.J.K., B.R. Wilcox, and G.F. Murray. Hemodynamic evaluation of the Lillehei-Kaster pivoting disc valve in patients.J. Thorac. Cardiovasc. Surg. 71:123–128, 1976.
Starr, A. and M.L. Edwards. Mitral replacement: Clinical experience with a ball valve prosthesis.Ann. Surg. 154:726–740, 1961.
Starr, D.S., G.M. Lawrie, J.F. Howell, and G.C. Morris. Clinical experience with the Smeloff-Cutter prosthesis: 1- to 12-year follow-up.Ann. Thorac. Surg. 30:448–453, 1980.
Steele, P., J. Rainwater, and R. Vogel. Platelet suppressant therapy in patients with prosthetic cardiac valves. Relationship of clinical effectiveness to alteration of platelet survival time.Circulation 60:910–913, 1979.
Stein, P.D. and H.N. Sabbah. Turbulent blood flow in the ascending aorta of humans with normal and diseased aortic valves.Circ. Res. 39:58–65, 1976.
Stein, P.D. and H.N. Sabbah. Possible contribution of turbulent blood flow to the development of prosthetic valve thrombosis. In:Recent Advances in Heart Valve Prostheses, edited by N.H.C. Hwang, New York, N.Y.: Raven Press, 1982, In press.
Stein, P.D., H.N. Sabbah, J.B. Lakier, D.J. Magilligan, Jr., and S. Goldstein. Frequency of the first heart sound in the assessment of stiffening of mitral bioprosthetic valves.Circulation 63:200–203, 1981.
Stewart, S. and J.A. DeWeese. The determinants of survival following reoperation on prosthetic cardiac valves.Ann. Thorac. Surg. 25:555–557, 1978.
Sullivan, J.M., D.E. Harken, and R. Gorlin. Pharmacologic control of thromboembolic complications of cardiac-valve replacement.N. Engl. J. Med. 284:1391–1394, 1971.
Sutton, M.G.St.J., M.St.J. Sutton, P. Oldershaw, R. Sacchetti, M. Paneth, S.C. Lennox, R.V. Gibson, and D.G. Gibson. Valve replacement without preoperative cardiac catheterization.N. Engl. J. Med. 305:1233–1238, 1981.
Teply, J.F., G.L. Grunkemeier, H. D'Acry Sutherland, L.E. Lambert, V.A. Johnson, and A. Starr. The ultimate prognosis after valve replacement: An assessment at twenty years.Ann. Thorac. Surg. 32: 111–119, 1981.
Thormann, J., M. Gottwik, M. Schlepper, and F. Hehrlein. Hemodynamic alterations induced by isoproterenol and pacing after aortic valve replacement with the Bjork-Shiley or St. Jude Medical prosthesis.Circulation 63:895–904, 1981.
Thubrikar, M., J.R. Skinner, J. Aouad, and S.P. Nolan. Geometry and performance of aortic bioprosthesisin vivo.Surg. Forum 31:341–342, 1980.
Tyers, G.F.O., E.H. Williams, W.S. Pierce, and J.A. Waldhausen. Present status of cardiac valve replacement.Curr. Probl. Surg. 14:1–78, 1977.
Wain, W.H., R. Greco, A. Ignegeri, E. Bodnar, and D.N. Ross. 15 years experience with 615 homograft and autograft aortic valve replacements.Int. J. Artif. Organs 3:169–172, 1980.
Watanakunakorn, C. Prosthetic valve infective endocarditis.Prog. Cardiovasc. Dis. 22:181–192, 1979.
Weinstein, A., D. Gibbons, S. Brown, and W. Ruff (editors). Implant Retrieval: Material and Biologic Analysis. National Bureau of Standards Special Publication 601. Gaithersburg, Maryland: National Bureau of Standards, 1981.
Weiting, D.W. Dynamic flow characteristics of heart valves. Ph.D. thesis. University of Texas, Austin, Texas, 1969.
Weldon, C.S. and T.B. Ferguson. The elimination of periprosthetic leaks as a complication of mitral valve replacement.Ann. Thorac. Surg. 18:447–455, 1974.
Wilson, W.R., G.K. Danielson, E.R. Giuliani, and J.E. Geraci. Prosthetic valve endocarditis.Mayo Clin. Proc. 57:155–161, 1982.
Wong, C.Y.H. and H.M. Spotnitz. Systolic and diastolic properties of the human left ventricle during valve replacement for chronic mitral regurgitation.Am J. Cardiol. 47:40–50, 1981.
Wortham, D.C., T.B. Tri, and T.E. Bowen. Hemodynamic evaluation of the St. Jude Medical valve prosthesis in the small aortic anulus.J. Thorac. Cardiovasc. Surg. 81:615–620, 1981.
Wright, J.T.M. Hydrodynamic evaluation of tissue valves. In:Tissue Heart Valves, edited by M.I. Ionescu. London-Boston: Butterworths, 1979, pp. 29–87.
Yoganathan, A.P., and W.H. Corcoran. In vitro velocity measurements in the vicinity of aortic prostheses.J. Biomech. 12:135–152, 1979.
Yoganathan, A.P., W.H. Corcoran, E.C. Harrison, and J.R. Carl. The Bjork-Shiley aortic prostheses: Flow characteristics, thrombus formation and tissue overgrowth.Circulation 58:70–76, 1978.
Yoganathan, A.P., H.H. Reamer, W.H. Corcoran, E.C. Harrison, I.A. Shulman, and W. Parnassus. The Starr-Edwards aortic ball valve: Flow characteristics, thrombus formation, and tissue overgrowth.Artif. Organs 5:6–17, 1981.
Zwart, H.H.J., G. Hicks, B. Schuster, M. Nathan, F. Tabrah, F. Wenzke, T. Ahmed, and R.A. DeWall. Clinical experience with the Lillehei-Kaster valve prosthesis.Ann. Thorac. Surg. 28:158–163, 1979.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Schoen, F.J., Titus, J.L. & Lawrie, G.M. Bioengineering aspects of heart valve replacement. Ann Biomed Eng 10, 97–128 (1982). https://doi.org/10.1007/BF02367460
Issue Date:
DOI: https://doi.org/10.1007/BF02367460