Summary
Two reversed-phase LC systems were investigated by frontal analysis for the determination of linear chromatographic conditions, as defined according to the isotherm concept. The Partisil ODS-3 bonded silica and the PRP-1 polystyrene-divinylbenzene resin were used as stationary phases together withtrans-2-hexen-al as test solute and methanol-water mixtures as mobile phases. Particular attention was paid to the respective influence of the two main parameters which may cause sorbent overloading, that is, the capacity factor (k′) and the solute concentration in the mobile phase (Cm). Provided that k′Cm≤10−2 M, linear chromatographic behaviour was observed for both sorbents, the maximum capacities of which were found greater than 1mmolg−1.
Similar content being viewed by others
References
S. Bitteur, R. Rosset, J. Chromatogr., in press (1987).
P. Gareil, L. Semerdjian, M. Caude, R. Rosset, J. High Resolut. Chromatogr./Chromatogr. Comm.,7, 123 (1984).
J. J. De Stefano, J. J. Kirkland, Anal. Chem.,47, 1130A (1975).
J. J. De Stefano, H. C. Beachell, J. Chromatogr. Sci.,10, 654 (1972).
J. J. Kirkland, J. Chromatogr.83, 149 (1973).
R. E. Mayors, Anal. Chem.44, 1722 (1972).
L. R. Snyder, Anal. Chem.,39, 698 (1967).
L. R. Snyder, in “Principles of Adsorption Chromatography”, M. Dekker, ed., New York, 1968, chap. 4.
R. P. W. Scott, P. Kucera, J. Chromatogr. Sci.,12, 473 (1974).
D. J. Pietrzyk, J. D. Stodola, Anal. Chem.,53, 1822 (1981).
J. N. Done, J. Chromatogr.,125, 43 (1976).
A. W. J. De Jong, H. Poppe, J. C. Kraak, J. Chromatogr.148, 127 (1978).
A. W. J. De Jong, H. Poppe, J. C. Kraak, J. Chromatogr.,209, 432 (1981).
A. W. J. De Jong, J. C. Kraak, H. Poppe, F. Noitgedacht, J. Chromatogr.,193, 181 (1980).
J. F. K. Huber, R. G. Gerritse, J. Chromatogr.,58, 137 (1971).
J. Jacobson, J. Frenz, C. Horvath, J. Chromatogr.,316, 53 (1984).
A. D. Wilks, D. J. Pietrzyk, Anal. Chem.,44, 676 (1972).
D. J. Pietrzyk, Talanta,16, 169 (1969).
F. Nevejans, M. Verzele, J. Chromatogr.,350, 145 (1985).
S. Bitteur, R. Rosset, submitted for publication in J. Food Sci. (1987).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Bitteur, S., Rosset, R. Comparison of octadecyl-bonded silica and styrene-divinylbenzene copolymer sorbents for trace enrichment purposes fundamental aspects II. Linear chromatographic behaviour of the extracting supports. Chromatographia 23, 163–168 (1987). https://doi.org/10.1007/BF02311473
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02311473