Summary
The separation of the products obtained by the hydrogenation of 1,5,9-cyclododecatriene stereoisomers on fused-silica capillary columns coated with dimethylsilicone and cyanopropylmethylsilicone stationary phases was investigated. Retention indices of cyclododecatrienes, cyclododecadienes, cyclododecenes and cyclododecane were determined at three temperatures. The respective standard deviations were 0.3 and 0.6 i.u. The influence of the polarity of the stationary phases on the chromatographic retention of these cyclic hydrocarbones is discussed.
Similar content being viewed by others
References
US Pat. 3, 400, 164 (1968).
German Pat. 1, 568, 323 (1971).
England Pat. 1, 233, 573 (1971).
German Pat. 1, 944, 382 (1970).
US Pat. 3, 631, 210 (1972).
German Pat. 2, 551, 586 (1974).
G. Schomburg, J. Chromatogr.,23, 18 (1966).
G. Schomburg, Anal. Chim. Acta,38, 45 (1967).
J. Hanika, I. Svoboda, V. Ruzicka, Collection Czechoslovak Chem. Commun.46, 1039 (1981).
W. Engewald, V. Billing, T. Welsch, Chromatographia,23, 590 (1987).
US Pat. 1, 233, 573 (1971).
Ya. G. Muchtarov, Neftekhimiya (Russ.),18, Nol, 30 (1978).
M. L. Peterson, J. Hirsch, J. Lipid. Res.1, 132 (1959).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Boneva, S., Balbolov, E. Capillary gas chromatography of hydrogenation products of 1,5,9-cyclododecatriene stereoisomers. Chromatographia 37, 277–280 (1993). https://doi.org/10.1007/BF02278633
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02278633