Summary
The application of capillary SFC for SIMDIST investigations of paraffins and waxes is reported. Pressure, density and temperature of the mobile phase are optimized to obtain high chromatographic resolution of complex mixtures of industrial products. Isothermal linear pressure programming and asymptotic pressure and density programming are used in the range from 15 to 35 MPa in the isothermic mode above 100°C. SFC chromatograms of natural and synthetic paraffins, microcrystalline wax and candle wax are compared. The retention behaviour of paraffin mixtures and waxes has been investigated on methyl/phenyl and biphenyl capillary columns. The polarity of the stationary phases influences the absolute retention time more than it influences the chromatographic resolution.
Similar content being viewed by others
References
W. Kreuder, Seifen, Oele, Fette, Wachse21, 257, 666 (1958).
W. R. Turner, D. S. Brown, D. V. Harrison, Ind. Eng. Chem.47, 1219 (1955).
H. E. Schwartz, R. G. Brownlee, M. M. Boduszynski, Fu Su, Anal. Chem.59, 1393 (1987).
H. E. Schwartz, J. W. Higgins, R. G. Brownlee, LC-GC Magazine4, 639 (1986).
P. A. Peaden, M. L. Lee J. Chromatogr.259, 1 (1983).
E. Leibnitz, H. G. Struppe, “Handbuch der Gaschromatographie”, Akademische Verlagsgesellschaft Geest & Portig, K.-G., Leipzig, 1984; p. 83.
Advances in Chromatography. Eds. C. Giddings, E. Grushka, P. R. Brown. Marcel Dekker Inc., 1989.
K. D. Bartle, M. P. Burke, A. A. Clifford, I. L. Davies, J. P. Kithinji, M. W. Raynor, G. F. Shilstone, A. Williams, Eur. Chromatogr. News2, 5 (1988).
W. Gmür, J. O. Bosset, E. Plattner, Mitt Geb. Lebensmittelunters. Hyg.78, 21 (1987).
P. A. Peaden, M. L. Lee, Liquid Chromatogr.5, 179 (1982).
J. C. Fjeldsted, W. P. Jackson, P. A. Peaden, M. L. Lee, J. Chromatogr. Sci.21, 222 (1983).
D. W. Later, E. R. Campbell, B. E. Richter, J. High Resolut. Chromatogr./Chromatogr. Comm.11, 65 (1988).
Y. Hirata, F. Nakata, S. Murata, Chromatographia23, 663 (1987).
M. L. Lee, B. Xu, E. C. Huang, N. M. Djordjevic, H.-C. K. Chang, K. E. Markides, J. Microcolumn Separat.1, 7 (1989).
K. E. Markides, M. L. Lee “SFC Applications”. On the occasion of the 1988 workshop on Supercritical Fluid Chromatography, Park City, Utah, 1988.
F. P. Schmitz, E. Klesper, J. High Resolut, Chromatogr./ Chromatogr. Comm.10, 519 (1987).
E. M. Fields, M. L. Lee, J. Chromatogr.349, 305 (1985).
D. Leyendecker, D. Leyendecker, F. P. Schmitz, E. Klesper, J. High Resolut. Chromatogr./Chromatogr. Comm.9, 525 (1986).
E. Klesper, D. Leyendecker, Int. Lab.16, 18 (1986).
M. D. Palmieri, J. Chem. Educ.65, A254 (1988).
J. C. Kuei, B. J. Tarbet, W. P. Jackson, J. S. Bradshaw, K. E. Markides, M. L. Lee, Chromatographia20, 25 (1985).
K. E. Markides, M. L. Lee “SFC Applications” Provo, Utah, Brigham Young University Press. 1988.
Capillary SFC-Applications; Packed SFC-Applications. Carlo Erba Instruments, Firmenschrift 1989.
R. D. Smith, H. T. Kalinoski, H. R. Udseth, Mass Spectrometry Rev.6, 445 (1987).
D. J. Bornhop, J. G. Wangsgaard, J. Chromatogr. Sci.27, 293 (1989).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Mellor, F., Ecknig, W., Richter, K. et al. Supercritical fluid chromatography of industrial paraffins and waxes. Chromatographia 35, 97–101 (1993). https://doi.org/10.1007/BF02278564
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02278564