Summary
The interfacing of a high performance liquid chromatograph, utilizing a dry-packed Spherisorb® C8 column (0.25×500 mm), with a four-sector tandem mass spectrometer via a frit-FAB probe is described. In order to utilize the sensitivity of the mass spectrometer, which is equipped with an array detector, the gradient solvent was split to a flow rate of 2–5 μL/min before the sample injector. The effluent flows directly into the mass spectrometer for the recording of the (M+H)+ ions of mixtures with the first of the two mass spectrometers (MS-1), or for their collision-induced-decomposition (CID) spectra by scanning the second mass spectrometer (MS-2). Those components that elute too close in time to allow the complete CID spectrum of each are diverted into a sample loop, which later can be switched in-line to the mass spectrometer to provide more time for collecting all the data. The method is demonstrated with a tryptic digest of the α-chain of human hemoglobin.
Similar content being viewed by others
References
R. S. Johnson, K. Biemann, Biochemistry26, 1209 (1987).
K. Biemann, in “Methods in Enzymology. Mass Spectrometry”,J. A. McCloskey, ed., Academic Press, Orlando, FL, 1990, in press.
R. S. Johnson, S. A. Martin, K. Biemann, Int. J. Mass Spectrom. Ion Processes86, 137 (1988).
K. Biemann, Biomed. Environ. Mass Spectrom.16, 99 (1988).
J. S. Cottrell, S. Evans, Anal. Chem.59, 1990 (1987).
J. A. Hill, S. A. Martin, J. E. Biller, K. Biemann, Biomed. Environ. Mass Spectrom.17, 147 (1988).
J. A. Hill, J. E. Biller, S. A. Martin, K. Biemann, K. Yoshidome, K. Sato, Int. J. Mass Spectrom. Ion Processes92, 211 (1989).
Y. Ito, T. Takeuchi, D. Ishii, M. Goto, J. Chromatogr.346, 161 (1985).
R. M. Caprioli, T. Fan, J. S. Cottrell, Anal. Chem.58, 2949 (1986).
L. J. Deterding, M. A. Moseley K. B. Tomer, J. W. Jorgenson, Anal. Chem.61, 2504 (1989).
G. Crescentini, F. Bruner, F. Mangani, G. Yafeng, Anal. Chem.60, 1659 (1988).
K. Sato, T. Asada, M. Ishihara, F. Kunihiro, Y. Kammei, E. Kubota, C. E. Costello, S. A. Martin, H. A. Scoble, K. Biemann, Anal. Chem.59, 1652 (1987).
J. A. Hill, J. E. Biller, S. A. Martin, K. Biemann, M. Ishihara, Proc. 37th ASMS Conf. Mass Spectrom. Allied Topics, 1989, p. 1077.
R. S. Johnson, K. Biemann, Biomed. Environ. Mass Spectrom.18, 945 (1989).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Cappiello, A., Palma, P., Papayannopoulos, I.A. et al. Efficient introduction of HPLC fractions into a high performance tandem mass spectrometer. Chromatographia 30, 477–483 (1990). https://doi.org/10.1007/BF02269791
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02269791