Efficient introduction of HPLC fractions into a high performance tandem mass spectrometer

  • Originals
  • Published:
Chromatographia Aims and scope Submit manuscript

Summary

The interfacing of a high performance liquid chromatograph, utilizing a dry-packed Spherisorb® C8 column (0.25×500 mm), with a four-sector tandem mass spectrometer via a frit-FAB probe is described. In order to utilize the sensitivity of the mass spectrometer, which is equipped with an array detector, the gradient solvent was split to a flow rate of 2–5 μL/min before the sample injector. The effluent flows directly into the mass spectrometer for the recording of the (M+H)+ ions of mixtures with the first of the two mass spectrometers (MS-1), or for their collision-induced-decomposition (CID) spectra by scanning the second mass spectrometer (MS-2). Those components that elute too close in time to allow the complete CID spectrum of each are diverted into a sample loop, which later can be switched in-line to the mass spectrometer to provide more time for collecting all the data. The method is demonstrated with a tryptic digest of the α-chain of human hemoglobin.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. R. S. Johnson, K. Biemann, Biochemistry26, 1209 (1987).

    Google Scholar 

  2. K. Biemann, in “Methods in Enzymology. Mass Spectrometry”,J. A. McCloskey, ed., Academic Press, Orlando, FL, 1990, in press.

    Google Scholar 

  3. R. S. Johnson, S. A. Martin, K. Biemann, Int. J. Mass Spectrom. Ion Processes86, 137 (1988).

    Google Scholar 

  4. K. Biemann, Biomed. Environ. Mass Spectrom.16, 99 (1988).

    Google Scholar 

  5. J. S. Cottrell, S. Evans, Anal. Chem.59, 1990 (1987).

    Google Scholar 

  6. J. A. Hill, S. A. Martin, J. E. Biller, K. Biemann, Biomed. Environ. Mass Spectrom.17, 147 (1988).

    Google Scholar 

  7. J. A. Hill, J. E. Biller, S. A. Martin, K. Biemann, K. Yoshidome, K. Sato, Int. J. Mass Spectrom. Ion Processes92, 211 (1989).

    Google Scholar 

  8. Y. Ito, T. Takeuchi, D. Ishii, M. Goto, J. Chromatogr.346, 161 (1985).

    Google Scholar 

  9. R. M. Caprioli, T. Fan, J. S. Cottrell, Anal. Chem.58, 2949 (1986).

    Google Scholar 

  10. L. J. Deterding, M. A. Moseley K. B. Tomer, J. W. Jorgenson, Anal. Chem.61, 2504 (1989).

    Google Scholar 

  11. G. Crescentini, F. Bruner, F. Mangani, G. Yafeng, Anal. Chem.60, 1659 (1988).

    Google Scholar 

  12. K. Sato, T. Asada, M. Ishihara, F. Kunihiro, Y. Kammei, E. Kubota, C. E. Costello, S. A. Martin, H. A. Scoble, K. Biemann, Anal. Chem.59, 1652 (1987).

    Google Scholar 

  13. J. A. Hill, J. E. Biller, S. A. Martin, K. Biemann, M. Ishihara, Proc. 37th ASMS Conf. Mass Spectrom. Allied Topics, 1989, p. 1077.

  14. R. S. Johnson, K. Biemann, Biomed. Environ. Mass Spectrom.18, 945 (1989).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Cappiello, A., Palma, P., Papayannopoulos, I.A. et al. Efficient introduction of HPLC fractions into a high performance tandem mass spectrometer. Chromatographia 30, 477–483 (1990). https://doi.org/10.1007/BF02269791

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02269791

Key Words

Navigation