Abstract

Experimental cataract development can be objectively monitored in rats by Scheimpflug slit-image photography and microdensitometric image analysis. Zeiss (Oberkochen, Federal Republic of Germany) has developed a new computerized slit-lamp measuring system that works according to the Scheimpflug principle; we have very successfully applied it to rats with streptozotocin-induced cataracta diabetica vera and with naphthalene-induced opacities. With these cataract models we tested the gyrase inhibitor compound, Ciprofloxacin (Bayer 09867), after 6 weeks' daily peroral application (20 mg/kg body weight) for differences in cataract progression indicating a possible cocataractogenic effect of the compound. When we compared the two different Scheimpflug methods, we found that the Zeiss-Scheimpflug measuring system SLC has some handling advantages with respect to animal cataract studies. If the equipment is to be fully used, complements to the program of the integrated computer part are necessary. The image-analytical results from the animals treated with Ciprofloxacin did not show any indication of cocataractogenic potential with respect to cataracta diabetica vera or naphthalene cataract.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Dragomirescu V, Hockwin O, Koch H-R, Sasaki K (1978) Development of a new equipment for rotating slit image photography according to Scheimpflug's principle. Interdiscipl. Topics Geront 13: 118–130

    Google Scholar 

  • Dragomirescu V, Hockwin O, Koch H-R (1980) Photo-cell device for slit beam adjustment to the optical axis of the eye in Scheimpflug photography. Ophthal Res 12: 78–86

    Google Scholar 

  • Hockwin O, Dragomirescu V (1981) Die Scheimpflug-Photographie des vorderen Augenabschnittes. Eine Methode zur Messung der Linsentransparenz im Rahmen einer Verlaufsbeobachtung. Z prakt Augenheil 2: 129–136

    Google Scholar 

  • Hockwin O, Dragomirescu V (1982) Verlaufsbeobachtungen von Linsentrübungen mit der Scheimpflug-Photographie und densitometrischer Bildanalyse. In: Hockwin O (ed) Altern der Linse, Symposium in Strasbourg, 1982. Mayr, Miesbach, pp 125–138

    Google Scholar 

  • Hockwin O, Dragomirescu V, Laser H (1983a) Measurements of lens transparency or its disturbances by densitometric image analysis of Scheimpflug photographs. Graefe's Arch Clin Exp Ophthalmol 219: 255–262

    Google Scholar 

  • Hockwin O, Dragomirescu V, Laser H (1983b) Age related changes in normal and cataractous human lens density obtained by microdensitometric image analysis of Scheimpflug-photographs. Lens Res 1: 207–220

    Google Scholar 

  • Hockwin O, Dragomirescu V, Shibata T, Laser H, Wegener A (1984a) Long-term follow-up examination of experimental cataracts in rats by Scheimpflug photography and densitometry. Graefe's Arch Clin Exp Ophthalmol 222: 20–25

    Article  Google Scholar 

  • Hockwin O, Lerman S, Ohrloff C (1984b) Investigations on lens transparency and its disturbances by microdensitometric analyses of Scheimpflug photographs. Curr Eye Res 3: 15–22

    Google Scholar 

  • Hockwin O, Lerman S, Laser H, Dragomirescu V (1985a) Image analysis of Scheimpflug photos of the lens by multiple linear microdensitometry. Lens Res 2: 337–350

    Google Scholar 

  • Hockwin O, Wegener A, Sisk DR, Dohrmann B, Kruse M (1985b) Efficacy of AL-1576 in preventing naphthalene cataract in three rat strains. A slit lamp and Scheimpflug photographic study. Lens Res 2: 113–119

    Google Scholar 

  • Lerman S, Hockwin O (1985) Automated biometry and densitography of the anterior segment of the eye. Graefe's Arch Clin Exp Ophthalmol 223: 121–129

    Article  Google Scholar 

  • Mayer H (1986) Improvements in evaluation of Scheimpflug photography. Lens Res 3: 227–237

    Google Scholar 

  • Mayer H, Irion KM (1985) New approach to area image analysis of Scheimpflug photos of the anterior eye segment. Ophthal Res 17: 106–110

    Google Scholar 

  • Zeiss (1985) Analytisches System zur Untersuchung der vorderen Augenmedien nach Scheimpflug mit Bildanalyse. Geratehandbuch, Teil 1

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hockwin, O., Laser, H. & Wegener, A. Investigations on rat eyes with diabetic cataract and naphthalene cataract by Zeiss-Scheimpflug measuring system SLC. Graefe's Arch Clin Exp Ophthalmol 224, 502–506 (1986). https://doi.org/10.1007/BF02154736

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02154736

Keywords

Navigation