Summary
The recording of physiological data on the magnetic tape is suitable 1) when automatical analysis of the experimental data should be performed in another laboratory or 2) in field research, when the transfer of an appropriate recorder or analyser is difficult. — Various possibilities of the use of magnetic recording, especially in the occupational physiology and hygiene, are discussed. “Direct recording” of the physiological data (on a conventional tape recorder, designed for recording of sound) is possible only for some kinds of signal, e.g. the E.M.G. or action potentials of nerve and muscle cells or fibres. When signals, including frequency components in the range of several c/s are to be recorded (e.g. the E.C.G. or E.E.G.), it is necessary to use a modulated carrier frequency for recording. Technical parameters of various modulation systems of recording are compared. The requirements on a system of recording for research in work physiology and hygiene are proposed. — In the second part of the paper a transistorized frequency modulator (carrier frequency 5000 c/s, frequency deviation ± 40%) and a transistorized demodulator are described. In connection with a small conventional magnetic tape recorder they enable to record a signal in the frequency range 0.5–800 c/s ensuring the signal-to-noise ratio more than 50:1; examples of records of E.E.G., E.M.G. and E.C.G. are presented.
Zusammenfassung
Die Magnettonbandaufnahme physiologischer Daten eignet sich: 1) wenn eine automatische Analyse der Daten in einem anderen Laboratorium durchgeführt werden soll oder 2) wenn bei einer Untersuchung im Betrieb der Transport eines geeigneten Registriergerätes oder Analysators schwierig ist. Verschiedene Möglichkeiten der Verwendung der Magnettonbandaufnahme, hauptsächlich im Gebiete der Arbeitsphysiologie und Hygiene, sind besprochen. Die «dirkte Aufnahme» physiologischer Daten (an einem für Schallaufnahme konstruierten Gerät) ist nur für einige Typen des Signals möglich, zum Beispiel für den E.M.G. oder für Aktionspotentiale der Nerven- und Muskelzellen bzw. Fasern. Für die Aufnahme von Signalen, die Frequenkomponenten im Bereiche einiger Hz behalten, muß man eine modulierte Trägerfrequenz verwenden. Technische Parameter verschiedener Modulationssysteme werden verglichen. Anforderungen an ein Aufnahmesystem für arbeitsphysiologische und hygienische Untersuchungen werden vorgeschlagen. — Im zweiten Teil wird ein aus Transistoren konstruierter Frequenzmodulator (Trägerfrequenz 5000 Hz, Frequenzhub ± 40%) und ein Demodulator beschrieben. In Verbindung mit einem kleinen Magnettonbandgerät ermöglichen sie die Aufnahme eines Signals im Frequenzbereich 0.5–800 Hz mit dem Signal-Rausch-Verhältnis von mehr als 50:1. Beispiele der Aufnhamen des E.E.G., E.M.G. und E.K.G. werden angeführt.
Similar content being viewed by others
Literature
Barlow, J.S. Electroenceph. clin. Neurophysiol.,9, 340–343 (1957).
Barlow, J.S. andM.A.B. Brazier Electroenceph. clin. Neurophysiol.,6, 321–325 (1954).
Beránek, R. Cs. Fysiol.,8, 290–299 (1959).
Bekkering, D.H. Electroenceph. clin. Neurophysiol.,8, 721 (1956).
Brazier, M.A.B. andJ.S. Barlow Electroenceph. clin. Neurophysiol.,8, 325–331 (1956).
Brazier, M.A.B. andJ.U. Casby Electroenceph. clin. Neurophysiol.,4, 201–211 (1952).
Brown, R.M., J.S. Barlow, D.F.O'Brien, W.T. Peake andC.D.Geisler: Appendix C in: Processing neuroelectric data, Massachussets Institute of Technology, Technical Report 351, July 7 (1959).
Burch, N.R. Electroenceph. clin. Neurophysiol.,11, 827–834 (1959).
Burch, N.R., A.J. Silverman andT.H. Greiner Electroenceph. clin. Neurophysiol.,8, 157, (1956).
Bures, J.: Personal communication (1958).
Coaton, J. J. Physiol. (London),125, 13P-14P (1954).
Cox, R.R., W.D. Obrist andC.E. Henry Electroenceph. clin. Neurophysiol.,7, 472 (1955).
Dickinson, C.J. Electrophysiological technique. Electron. Eng., London (1950).
Drechsler, B. andJ. Krecan Cs. Fysiol.,6, 527–530 (1957).
Gastaut, Jus, Jus, Morrell, Storm van Leeuwen, Dongier, Naquet, Regis, Roger, Bekkering, Kamp andWerre Electroenceph. clin. Neurophysiol.,9, 1–34, (1957).
Haapanen, L. Acta physiol. scand.,29, Suppl. 106 (1953).
Hill, D. andD. Parr, editors: Electroencephalography, London (1950).
Holzer, W. Kathodenstrahloscillographie in Biologie und Medizin. Maudrich, Wien (1930).
Horváth, M., R. Fischer, J. Formánek, D. Frantíková andA. Mikiska Pracovní Lékarství,13, 163–168 (1961).
Kozevnikov, V.V. andA.M. Soroko Fiziol. Z. (Mosk.),43, 187–191 (1957).
Krecan, J. Amatérské Radio,8, 65–68 (1959).
Kuiper, I. J.: personal communication (1960).
Liberson, W.T. andR.W. Smith Electroenceph. clin. Neurophysiol.,7, 649–652 (1955).
Marchand N. Convention Record of the I.R.E.,8, 48–56 (1953).
Mattews, B.H.C.: J. Physiol. (London),81, 28P (1934).
Mikiska, A. Activ. nerv. super.,3, 92–110 (1961).
Nichols, M.H. andL.L. Rauch: Radio Telemetry. London & New York (1956).
Pórszász, J. andF. Szabó Acta physiol. Acad. Sci. hungar.,15, 231–235 (1959).
Schaefer, H. Elektrophysiologie. Bd. I. Deuticke, Wien (1940).
Shaper, H.B. Proc. I.R.E.,33, 755 (1945).
Tönnies, J.F. Rev. sci. Instr.,9, 95–97 (1938).
Vodolazskij, L.A. Technika kliniceskoj elektrografii. Medgiz, Moskva (1952).
Walter, W. Grey Electroenceph. clin. Neurophysiol.,10, 367–368 (1958).
Walter, W. Grey: Personal communication (1959).
Whitfield, I.C. An introduction to electronics for physiological workers. Macmillan, London (1957).
Young, W.D.: National Telemetering Conference Record, 228–230 (1953).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Mikiska, A. Recording of physiological data on the magnetic tape: application in work physiology and hygiene. Z. Prāventivmed 7, 283–300 (1962). https://doi.org/10.1007/BF02031337
Issue Date: