ABAC Identibiogramme: Prototype of an automated system for identification of Enterobacteria

  • Original Articles
  • Published:
European Journal of Clinical Microbiology Aims and scope Submit manuscript

Abstract

The ABAC Identibiogramme, an automated, computerized system for the identification and antimicrobial susceptibility testing of theEnterobacteriaceae has been developed recently. The biological basis of the system resides in lyophilized, highly discriminating media enclosed in wells of an automatically inoculated disposable cartridge. The introduction of a suitable specimen rehydrates and inoculates the media in the wells. After incubation for 16 to 18 h at 37 °C and the addition of only one reagent (Kovacs reagent), the media changes and the results obtained are interpreted by an automated optical system and a computer. The antibiogram is also used by the computer to confirm the biochemical identification of the organism. The identification accuracy of a prototype of the ABAC Identibiogramme system was compared with that of API 20 E and conventional methods using a total of 1,290 clinical isolates. The ABAC Identibiogramme correctly identified 96.8 % of the organisms tested, misidentified 2.4 % and failed to identify 0.8 %. The results demonstrate the high reliability and good identification performance of the ABAC Identibiogramme in comparison to API 20 E and conventional methods.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Aldrige, K. E., Gardner, B. B., Clark, S. J., Metsen, J. M.: Comparison of Micro-ID, API 20 E, and conventional media systems in identification ofEnterobacteriaceae. Journal of Clinical Microbiology 1978, 7: 507–513.

    PubMed  Google Scholar 

  2. Aldridge, C., Jones, P. W., Gibson, S., Lanham, J., Meyer, M., Vannest, R., Charles, R.: Automated microbiological detection/identification system. Journal of Clinical Microbiology 1977, 6: 406–413.

    PubMed  Google Scholar 

  3. Brown, S. D., Washington, J. A.: Evaluation of the Repliscan System for identification ofEnterobacteriaceae. Journal of Clinical Microbiology 1978, 8: 695–699.

    PubMed  Google Scholar 

  4. Buissière, J., Nardon, P.: Microméthode d'identification des bactéries. I. Intérêt de la quantification des caractères biochimiques. Annales de l'Institut Pasteur 1968, 115: 218–231.

    PubMed  Google Scholar 

  5. Davis, J. R., Stager, C. E., Wende, R. D., Quadri, H.: Clinical laboratory evaluation of the Auto Microbic SystemEnterobacteriaceae biochemical card. Journal of Clinical Microbiology 1981, 14: 370–375.

    PubMed  Google Scholar 

  6. Hansen, S. L., Hardesty, D. R., Myers, B. M.: Evaluation of the BBL Minitek system for the identification ofEnterobacteriaceae. Applied Microbiology 1974, 28: 798–801.

    PubMed  Google Scholar 

  7. McCracken, A. W., Martin, W. J., McCarthy, L. R., Schwab, D. A., Cooper, B. H., Helgeson, N. G. P., Prowant, S., Robson, J.: Evaluation of the MS2 System for rapid identification ofEnterobacteriaceae. Journal of Clinical Microbiology 1980, 12: 684–689.

    PubMed  Google Scholar 

  8. Marymont, J. H., Gavan, T. J.: Performance ofEnterobacteriaceae identification systems: an analysis of College of American Pathologist survey data. American Journal of Clinical Pathology 1978, 70, Supplement: 539–547.

    PubMed  Google Scholar 

  9. Nord, C. E., Londberg, A. A., Dahlback, A.: Evaluation of five test kits-API, Auxotab, Enterotube, Patho Tec, and R/B for identification ofEnterobacteriaceae. Medical Microbiology and Immunology 1974, 159: 211–220.

    PubMed  Google Scholar 

  10. Bergogne-Berezin, E., Thabaut, A., Durosoir, J. L., Berthelot, G., Courtoux, D.: L'antibiogramme automatique Médecine et Maladies Infectieuses 1978, 8: 15–19.

    Article  Google Scholar 

  11. Drugeon, H., Courtieu, A. L.: Comparaison de deux méthodes d'antibiogramme: diffusion en gélose et méthode automatisée par l'appareil ABAC. Annales de Biologie Clinique 1978, 36: 363–367.

    PubMed  Google Scholar 

  12. Véron, M., Ghnassia, J. C., Berche, P., Daoulas-Le-Bourdelle, F., Avril, J. L., Fauchere, J. L., de Meirleire, F., Descamps, P.: Comparaison par rapport à la concentration minimale inhibitrice, des résultats fournis par deux méthodes d'antibiogramme: la technique de disques et une technique automatisée en milieu liquide (procédé ABAC). Annales de Microbiologie 1978, 129 A: 473–502.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Durosoir, J.L. ABAC Identibiogramme: Prototype of an automated system for identification of Enterobacteria. Eur. J, Clin. Microbiol. 2, 26–31 (1983). https://doi.org/10.1007/BF02019919

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02019919

Keywords

Navigation