Skip to main content
Log in

Isothermal and isobaric PVT-measurements of atactic polymers

  • Polymers and Plastics
  • Published:
Journal of thermal analysis Aims and scope Submit manuscript

Abstract

It is evidenced that due to the kinetic character of the glass transition as a ‘freeze in’ process, PVT measurements extended over the glass transition range depend not only on the thermal history but also on the pressure acting during the formation of the polymeric glasses. As a consequence metastable glasses are formed which show during heating of the glassy polymer through the glass transition range ‘volume relaxation zones’, characterized by a retarded increase or even decrease of the volume. The width of the ‘relaxation zone’ increases with increasing pressure and depends additional on the mode of operation used during the PVT measurements. In the same time a pressure induced shift of the glass temperature to higher temperatures is observed, the shift being the greater the stiffer the polymer, i.e. the higher the glass temperature of the polymer at atmospheric pressure. Due to the metastable character of polymeric glasses the evaluation of universal equations of states is thus not ingenious for polymeric glasses, because the deduced EOS will be valid only for that given glass characterized by a well defined thermal and pressure history. Additionally the EOS is influenced by the unknown time dependent aging and relaxation processes within polymeric glasses.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. J. H. Hildebrand and R. L. Scott, ‘The Solubility of Nonelectrolytes’, 3rd ed. Van Nostrand-Reinhold Publ., Princeton N. J. 1950; J. Biros, L. Zeman and D. Patterson, Macromolecules, 4 (1971) 30; P. J. Flory, R. A. Orwoll and A. Vrij, J. Amer. Chem. Soc., 86 (1964) 3507; I. C. Sanchez and R. H. Lacombe, J. Phys. Chem., 80 (1976) 2352.

    Google Scholar 

  2. B. Rudolf, H. A. Schneider and H.-J. Cantow, Polymer Bull., 34 (1995) 109.

    Article  Google Scholar 

  3. I. C. Sanchez, J. Oho and W.-J. Chen, Macromolecules, 26 (1993) 4234.

    Article  Google Scholar 

  4. G. Rehage, J. Macromol. Sci.-Phys., B13 (1980) 423.

    Google Scholar 

  5. A. Quach and R. Simha, J. Appl. Phys., 42 (1971) 4592.

    Article  Google Scholar 

  6. P. Zoller and H. H. Hoehn, J. Polymer Sci, Polymer Phys. Ed., 20 (1982) 1385.

    Google Scholar 

  7. P. Zoller, P. Bolli, V. Pahud and H. Ackermann, Rev. Sci. Instrum., 47 (1977) 948.

    Article  Google Scholar 

  8. A. Eckstein and H. A. Schneider, J. Thermal Anal., (in press).

  9. H. A. Schneider, B. Rudolf, K. Karlou and H.-J. Cantow, Polymer Bull., 32 (1994) 645.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Schneider, H.A. Isothermal and isobaric PVT-measurements of atactic polymers. Journal of Thermal Analysis 47, 453–461 (1996). https://doi.org/10.1007/BF01983987

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01983987

Keywords

Navigation