Using the scanning (differential) method and a PE DSC in continuous heating regime as well as the integral (enthalpic) method and a SETARAM DSC in a discontinuous heating regime the specific heats of several metallic glassy ribbons were measured. The linearc p M(T) dependencies in the as-quenched, relaxed and also the stable crystalline forms of the ribbons in the medium temperature region were found. The room temperature specific heats of these ribbons, the excess contributions due to the relaxed glassy state as well as the non-relaxed glassy state were determined.
The sensitivity ofc p M(T) measurements of metallic ribbons was better than 0.2%, the long term reproducibility in the case of glassy ribbons was 2%. They are related to the errors inc p M(T) measurements of synthetic sapphire standard or bulk chalcogenide glasses.
Zusammenfassung
Unter Anwendung des Scanning- (Differential-) Verfahrens und einem PE DSC in kontinuierlichen Heizsystemen sowie des Integral- (Enthalpie-) Verfahrens und einem SETARAM DSC in diskontinuierlichen Heizsystemen wurde die spezifische Wärme diverser metallisch-glasartiger Bänder gemessen. Im abgeschreckten, entspannten Zustand und auch in den kristallinen Formen der Bänder konnte in der mittleren Temperaturregion eine linearec p M(T) Abhängigkeit gefunden werden. Sowohl die spezifischen Wärmen dieser Bänder bei Raumtemperatur, der zusätzliche Beitrag im entspannten glasartigen Zustand als auch im nichtentspannten glasartigen Zustand wurden bestimmt. Die Empfindlichkeit beic p M(T)-Messungen metallischer Bänder war besser als 0.2%, die Langzeitreproduzierbarkeit betrug im Falle glasartiger Bänder 2%. Sie wurden auf die Fehlergrö\en vonc p M(T)-Messungen an einem synthetischen Saphir-Standard oder an massiven Chalkogenidgläsern bezogen.
Similar content being viewed by others
References
K. L. Kolmarek, Ber. Bunsen. Phys. Chem., 87 (1983) 709.
Q. Xu and K. Ichikawa, J. Phys. C: Solid State Phys., 19 (1986) 7145.
F. GrØnvold, S. StØlen, E. F. Westrum Jr., A. K. Lablan and B. Uhrenius, Thermochim. Acta, 129 (1988) 115.
F. Righini, R. B. Roberts and A. Rosso, Int. J. Thermophys., 6 (1985) 681.
H. S. Chen and D. Turnbull, J. Appl. Phys., 38 (1967) 3646.
D. Vucelic, V. Vucelik and N. Juranic, J. Thermal Anal., 5 (1973) 459.
S. C. Mraw and D. F. Naas, J. Chem. Thermodyn., 11 (1979) 567.
Ch. Cunat and J. Charles, Mem. Rev. Sci. Met., 4 (1982) 117.
F. Franks and T. Wakabayashi, Z. Phys. Chem., Neue Folge, 155 (1987) 171.
H. Neumann, E. Nowak and M. S. Omar, Cryst. Res. Technol., 22 (1987) 1437.
J. V. Dubrawski, Thermochim. Acta, 120 (1987) 257.
R. J. J. Martis, T. J. Taylor and Y. P. Khanna, J. Non-Cryst. Solids, 94 (1987) 209.
H. W. Kui and D. Turbull, J. Non-Cryst. Solids, 94 (1987) 62.
P. Claudy, J. C. Commercon and J. M. Létoffé, Thermochim. Acta, 128 (1988) 251.
M. Kamimoto, Int J. Thermophys., 11 (1990) 305.
E. Illeková, B. Aba and F. A. Kuhnast, Thermochim. Acta, to be published.
E. Illeková, Ch. Cunat, F. A. Kuhnast, A. Aharoune and J. M. Fiorani, Thermochim. Acta, to be published.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Illeková, E., Aba, B. & Kuhnast, F.A. Is the DSC technique capable of determining accurate specific heats of metallic ribbons?. Journal of Thermal Analysis 38, 397–407 (1992). https://doi.org/10.1007/BF01915504
Issue Date:
DOI: https://doi.org/10.1007/BF01915504