Abstract
Dual-energy X-ray absorptiometry (DXA) has become the measurement of choice for multicenter trials with bone density endpoints. When performing DXA measurements with several different systems, it is important to implement a quality assurance program to guarantee that any observed density changes are real and not due to machine and/or operator variability. In this study, we present a series of procedures based on phantom measurements designed to monitor DXA instrument stability. Techniques for longitudinal evaluation of machine performance and cross-calibration of instruments are described. These procedures are then demonstrated using quality assurance data collected from a number of different DXA scanners. Together these methods provide a defined approach to instrument quality control. Though based primarily on the use of spinal phantoms, these procedures can be generalized for use in any multicenter DXA study.
Similar content being viewed by others
References
Orwoll ES, Oviatt SK. Longitudinal precision of dual-energy x-ray absorptiometry in a multicenter study. J Bone Miner Res 1991;6:191–7.
Trevisian C, Gandolini GG, Sibilla P, Penotti M, Caraceni MP, Ortolani S. Bone mass measurement by DXA: influence of analysis procedures and interunit variation. J Bone Miner Res 1992;7:1373–82.
Glüer CC, Faulkner KG, Estilo MJ, Engleke K, Rosin J, Genant HK. Quality assurance for bone densitometry research studies: concept and impact. Osteoporosis Int 1993;3:227–35.
Miller CG. Bone density measurements in clinical trials: the challenge of ensuring optimal data. Br J Clin Res 1993;4:113–20.
Orwoll ES, Oviatt SK, Biddle JA. Precision of dual-energy x-ray absorpiometry: development of quality control rules and their application in longitudinal studies. J Bone Miner Res 1993;8:693–9.
Wahner HW, Looker A, Dunn WL, Walters LC, Hauser MF, Novak C. Quality control of bone densitometry in a National Health Survey (NHANES III) using three mobile examination centers. J Bone Miner Res 1994;9:951–60.
Kalender WA. A phantom for standardization and quality control in spinal bone mineral measurements by QCT and DXA: design considerations and specifications. Med Phys 1992;19:583–6.
Reid DM, Lanham SA, McDonald AG, Avenell A, Fenner JAK, Boyle IT, et al. Speed and comparability of 3 dual-energy x-ray absorptiometry (DXA) models. In: Christiansen C, Overgaard K, editors. Osteoporosis 1990. Proceedings of the Third International Symposium on Osteoporosis. Copenhagen: Osteoporosis, 1990:575–7.
Pocock NA, Sambrook PN, Nguyen T, Kelly P, Freund J, Eisman JA. Assessment of spinal and femoral bone density by dual x-ray absorptiometry: comparison of Lunar and Hologic instruments. J Bone Miner Res 1992;7:1081–4.
Lai KC, Goodsitt MM, Murano R, Chesnut CH III. A comparison of two dual-energy x-ray absorptiometry systems for spinal bone mineral measurement. Calcif Tissue Int 1992;50:203–8.
Genant HK, Grampp S, Glueer CC, Faulkner KG, Jergas M, Engelke K, et al. Universal standardization for dual x-ray absorptiometry: patient and phantom cross-calibration results. J Bone Miner Res 1994;9:1503–14.
Westgard JO, Barry PL, Hung MR, Groth T. A multirule Shewart chart for quality control in clinical chemistry. Clin Chem 1981;27:493–501.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Faulkner, K.G., McClung, M.R. Quality control of DXA instruments in multicenter trials. Osteoporosis Int 5, 218–227 (1995). https://doi.org/10.1007/BF01774010
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF01774010