Skip to main content
Log in

Transcranial Dopplersonography of the vertebro-basilar system

  • Published:
Acta Neurochirurgica Aims and scope Submit manuscript

Summary

This is the first investigation of distances, angles and locations of the vascular system in the posterior fossa.

The distances from the skin surface of the neck, where a Doppler probe is positioned for transforaminal insonation, to the brainsystem have been measured in sagittal MRI pictures. The mean distance from the insonation point to the beginning of the basilar artery (BA) is 66.6 mm in males, 58.8 in femals. The distance to the end of the BA is 90.0 and 80.4, respectively. These distances are relevant for locating the vertebral and basilar arteries. The insonation angles to the VA and BA range from 20° to 30°. Correlations with Doppler findings are discussed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Aaslid R, Markwalder T-H, Nomes H (1982) Noninvasive transcranial Doppler ultrasound recordings of flow velocity in basal cerebral arteries. J Neurosurg 57: 769–774

    PubMed  Google Scholar 

  2. Krayenbühl H, Yaşargil MG: In: Huber P (1979) Zerebrale Angiographie in Klinik und Praxis. G Thieme, Stuttgart, p 158

    Google Scholar 

  3. Schnitzlein HN, Murtagh FR (1985) Imaging anatomy of the head and spine. Urban & Schwarzenberg, Baltimore München

    Google Scholar 

  4. Scialfa G, Ruggiero G, Salamon G, Michotey P (1975) Post mortem investigation of the vertebrobasilar system. Acta Radiol [Suppl] 374: 259–269

    Google Scholar 

  5. Volc D, Possnigg G (1987) Dreidimensionale transcranielle Dopplersonographie-Normalwerte und pathologische Veränderungen. Neuropsychiatrie 2, 2

    Google Scholar 

  6. Busch W (1966) Beitrag zur Morphologie und Pathologie der A. basilaris. Arch Psychiat Z Neurol 208: 326–344

    Google Scholar 

  7. Arnolds BJ, von Reuthern G-M (1986) Transcranial Doppler sonography. Examination technique and normal reference values. Ultrasound Med Biol 12: 115–123

    PubMed  Google Scholar 

  8. Zeumer H, Hacke W, Kolmann H-L, Poeck K (1982) Lokale Fibrinolysetherapie bei Basilaris-Thrombose. Dtsch med Wschr 107: 728

    PubMed  Google Scholar 

  9. Ringelstein EB (1985) Ultraschalldiagnostik am vertebrobasilären Kreislauf. Ultraschall 6: 60–67

    Google Scholar 

  10. Vogel H (1986) Maße und Distanzen in der Sonographie und Computertomographie. Ecomed Landsky-Lech

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Volc, D., Possnigg, G., Grisold, W. et al. Transcranial Dopplersonography of the vertebro-basilar system. Acta neurochir 90, 136–138 (1988). https://doi.org/10.1007/BF01560568

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01560568

Keywords

Navigation