Abstract
The performance indicators for a quantitative analysis (random and systematic uncertainties) are defined, and their origin in SIMS (secondary ion mass spectrometry) is discussed. The different methods for quantitative SIMS analysis: calibration curve approach, implanted standard method, relative sensitivity factor (RSF) method, are discussed. Examples are given for successful quantitative SIMS analyses of epilayers, implanted depth profiles and interface (IF) impurity distribution. In conclusion, a comparison is made between SIMS and other advanced techniques for thin film analysis.
Similar content being viewed by others
References
A. Benninghoven, F. G. Ruedenauer, H. W. Werner,Secondary Ion Mass Spectrometry, Wiley, New York, 1987.
A. Benninghoven, F. G. Ruedenauer, H. W. Werner,Secondary Ion Mass Spectrometry, Wiley, New York, 1987, p. 784.
A. Benninghoven, F. G. Ruedenauer, H. W. Werner,Secondary Ion Mass Spectrometry, Wiley, New York, 1987, p. 35.
E. Bruninx, L. C. Bastings,Philips Technical Review,1974,34, 350.
A. Benninghoven, F. G. Ruedenauer, H. W. Werner,Secondary Ion Mass Spectrometry, Wiley, New York, 1987, p. 2.
A. Benninghoven, F. G. Ruedenauer, H. W. Werner,Secondary Ion Mass Spectrometry, Wiley, New York, 1987, p. 3.
A. Benninghoven, F. G. Ruedenauer, H. W. Werner,Secondary Ion Mass Spectrometry, Wiley, New York, 1987, p. 30.
A. Benninghoven, F. G. Ruedenauer, H. W. Werner,Secondary Ion Mass Spectrometry, Wiley, New York, 1987, p. 296–326.
Z. Sroubek, in:Proceedings of Secondary Ion Mass Spectrometry VI (A. Benninghoven, et al., eds.), Wiley, 1987, p. 17.
R. Kelly, in:Proceedings of Secondary Ion Mass Spectrometry II (A. Benninghoven, et al., eds.), Springer, Berlin Heidelberg New York, 1979, p. 21.
M. Yu. Yu, in:Proceedings of Secondary Ion Mass Spectrometry VI (A. Benninghoven, et al., eds.), Wiley, New York, 1987, p. 41.
P. Zalm, Vacuum,1994, in press.
H. D. Hagstrum, in:Inelastic Ion Surface Collisions, Academic Press, New York, 1977, p. 1.
A. E. Morgan et al., in:Proceedings 4th Int. Conf. Solid Surf. (D. A. Degras et al., eds.), 1980, p. 1238.
K. Wittmaack,Rad. Eff. 1982,63.
M. L. Yu,Nucl. Inst. Meth. 1986,B15, 151.
R. Canteri, L. Moro, M. Anderle, in:Proceedings of Secondary Ion Mass Spectrometry VII (A. Benninghoven, et al., eds.), Wiley, New York, 1989, p. 135.
G. Stingeder, M. Grundner, M. Grasserbauer,Surf. Interf. Anal. 1988,11, 407.
R. Canteri, L. Moro, M. Anderle, in:Proceedings of Secondary Ion Mass Spectrometry VIII (A. Benninghoven, et al., eds.), Wiley, New York, 1991, p. 135.
N. Warmoltz,Private communication, 1993.
H. W. Werner, in:Developments in Applied Spectroscopy, Vol. 7A, Plenum, New York, 1969, p. 252.
G. Slodzian,Surf. Sci. 1975,48, 161.
H. W. Werner,Surf. Interf. Anal. 1980,2, 56.
G. J. Scilla, G. H. Morrison,Anal. Chem. 1977,49, 1529.
M. Grasserbauer, G. Stingeder, H. Poetzl, E. Guerrero,Fresenius Z. Anal. Chem. 1986,323, 429.
G. Stingeder, M. Grasserbauer, E. Guerrero, H. Pötzl, R. Tidert,Fresenius Z. Anal. Chem. 1983,314, 304.
H. W. Werner, in:Special Technical Publication 699, ASTM, 1919 Race Street, Philadelphia, PA-19103, 1980, p. 81. Courtesy of F. Degreve, F. Figaret, P. Laty, International Conference on Secondary Ion Mass Spectrometry I, Muenster, 1976, unpublished.
H. W. Werner et al.J. Vac. Sci. Tech. 1984,A2, 726.
H. W. Werner et al.J. Appl Phys. 1976,47, 1232.
G. Stingeder,Fresenius Z. Anal. Chem. 1987,327, 225.
A. Benninghoven, F. G. Ruedenauer, H. W. Werner,Secondary Ion Mass Spectrometry, Wiley, New York, 1987, p. 813.
H. W. Werner,Acta Electronica,1976,19, 53 andSurf. Interf. Anal. 1980,2, 61.
C. J. Vriezema, P. Zalm,Surf. Interf. Anal. 1991,17, 875; see also [26], p. 92.
H. W. Werner,Surf. Sci. 1973,35, 458.
A. Benninghoven, F. G. Ruedenauer, H. W. Werner,Secondary Ion Mass Spectrometry, Wiley, New York, 1987, p. 765.
A. Wittmaack,Nucl. Instrum. Method. 1980,168, 343.
H. W. Werner,Vakuum Technik 1967,17, 37.
H. W. Werner, in:Microelectronic Materials and Processes, Kluwer, Dordrecht, 1980, pp. 845–979.
A. Benninghoven, F. G. Ruedenauer, H. W. Werner,Secondary Ion Mass Spectrometry, Wiley, New York, 1987, p. 281.
V. Leroy, J. P. Servais, L. Habraken,CRM Report 1973,35, 69; Centre Recherche Metallurgique, Liege (B).
R. Shimizu, T. Ishitani, T. Kondo, H. Tamura,Anal. Chem. 1975,47, 1020.
R. G. Wilson,J. Appl. Phys. 1988,63, 5121.
R. G. Wilson, F. A. Stevie, Ch. W. Magee,Secondary Ion Mass Spectrometry VII, Wiley, New York, 1989.
H. W. Werner,Acta Electronica,1976,19, 53.
A. Benhinghoven, F. G. Ruedenauer, H. W. Werner,Secondary Ion Mass Spectrometry, Wiley, New York, 1987, 779.
D. P. Leta, G. H. Morrison,Anal. Chem. 1980,52, 277.
R. G. Wilson, F. A. Stevie, G. E. Lux, C. L. Kirschbaum, F. Frank, J. Pallix,Surf. Coatings Techn. 1992,51, 358.
R. G. Wilson, F. A. Stevie, Ch. W. Magee,Secondary Ion Mass Spectrometry, Wiley, New York, 1989, p. 3.1.1.
R. G. Wilson, F. A. Stevie, Ch. W. Magee,Secondary Ion Mass Spectrometry, Wiley, New York, 1989, p. 3.1.3.
R. G. Wilson, F. A. Stevie, Ch. W. Magee,Secondary Ion Mass Spectrometry, Wiley, New York, 1989, App. 20.
R. G. Wilson, F. A. Stevie, Ch. W. Magee,Secondary Ion Mass Spectrometry, Wiley, New York, 1989, p. 4.1.4.
P. Zalm, in:Proceedings of Secondary Ion Mass Spectrometry VIII (A. Benninghoven, et al., eds), Wiley, New York, 1991, p. 309.
R. S. Muller, Th. I. Kamins,Device Electronics for Integrated Circuits, 2nd. Ed., Wiley, New York, 1986, p. 112; see also [55].
A. E. Morgan, Y. Chen,J. Vac. Sci. Tech. 1984,A2, 1266.
A. E. Morgan, P. Maillot., in:Proceedings of Secondary Ion Mass Spectrometry VI (A. Benninghoven, et al., eds), Wiley, New York, 1987, p. 709.
P. Willich,Mikrochim. Acta [Suppl] 1992,12, 1.
H. W. Werner, in:Proceedings 40th Scottish Universities Summerschools on Physics (A. Fitzgerald, ed.), Dundee, 1992, pp. 399–417.
E. Niehuis, in:Proceedings of Secondary Ion Mass Spectrometry VIII (A. Benninghoven, et al., eds.), Wiley, New York, 1991, p. 269.
E. Stumpe, H. Oechsner, H. Schoof,Appl. Phys. 1979,20, 55; and H. Oechsner,Topics Current Phys. 1984,37, 63.
Y. Kikuta, H. Jennett.,Anal. Sci. 1992,8, 179.
International Standard ISO 5725,Precision of Test Methods, Determination of Repeatability and Reproducibility, 2nd Ed., 1986 (ref. nr. ISO 5725–1986 (E)), pp. 1–6.
IUPAC,Compendium of Analytical Nomenclature, Definitive Rules (H. Irving, ed.), 1977, Pergamon, New York, 1978, p. 9 and p. 116.
1992 Annual Book of ASTM Standards, Section 3: Metal Test Methods and Analytical Procedures, Vol. 03.06, ASTM, 1919 Race Street, PA-19103 Philadelphia, U.S.A., 1992, p. 249.
I. Kolthoff (ed.),Treatise on Analytical Chemistry, Part I: Theory and Practice, Vol. 1, Section B4: Sources of Error and the Approach to Accuracy in Analytical Chemistry, Wiley, New York, 1978, p. 270.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Werner, H. Quantitative analysis of films by ion microbeam methods. II: SIMS. Mikrochim Acta 114, 107–127 (1994). https://doi.org/10.1007/BF01244536
Issue Date:
DOI: https://doi.org/10.1007/BF01244536