Abstract
This paper examines the viability of using X-ray diffraction to monitor the loss of lithium from the surface of aluminium-lithium alloys during heat treatment in air at 530° C. It has been found that the amount of Li2CO3, a major constituent of the surface film, can be related to the extent of lithium depletion as determined by microhardness measurements. The technique is very sensitive to the amount of lithium depletion, readily detecting the carbonate after only five minutes exposure at 530° C. Cooling rate, initial surface removal, surface finish and alloy composition were all found to influence results, but, provided these parameters are controlled, it is concluded that X-ray diffraction is a rapid and non-destructive method of monitoring lithium depletion in aluminium-lithium alloys.
Similar content being viewed by others
References
S. Fox, H. M. Flower andD. S. McDarmaid,Scripta Metall. 20 (1986) 71.
Idem, in “Aluminium-Lithium III”, edited by C. Baker, P. J. Gregson, S. J. Harris and C. J. Peel, (Institute of Metals, London, 1986) pp. 263–272.
A. F. Smith, in “Aluminium-Lithium III”, edited by C. Baker, P. J. Gregson, S. J. Harris and C. J. Peel, (Institute of Metals, London, 1986) pp. 164–172.
M. Burke andJ. M. Papazian, in “Aluminium-Lithium III”, edited by C. Baker, P. J. Gregson, S. J. Harris and C. J. Peel, (Institute of Metals, London, 1986) pp. 287–293.
J. A. Wert andA. B. Ward,Scripta Metall. 19 (1985) 367.
H. Ueda, A. Matsui, M. Furukawa, Y. Miura andN. Nemoto,J. Jpn. Inst. Met. 49 (1985) 562.
J. M. Papazian, R. L. Schulte andP. N. Adler,Met. Trans. 17A (1986) 635.
R. L. Schulte, J. M. Papazian andP. N. Adler,Nucl. Instrum. Meth. Phys. Res. B15 (1986) 550.
F. Abd El-Salam, A. I. Eatah andA. Tawfik,Phys. Status Solidi a 75 (1983) 375.
J. M. Papazian, G. G. Bott andP. Shaw,Mater. Sci. Eng. 94 (1987) 219.
D. S. McDarmaid, S. Fox andH. M. Flower, in European materials research society conference “Advanced materials research and development for transport” 26–28 Nov 1985, (Council of Europe, Strasbourg, 1985).
R. F. Ashton, D. S. Thompson, E. A. Starke Jr. andF. S. Lin, in “Aluminium-Lithium III”, edited by C. Baker, P. J. Gregson, S. J. Harris and C. J. Peel, (Institute of Metals, London, 1986) pp. 66–77.
M. Ahmad,Metall. Trans. 18A (1987) 681.
P. G. Partridge, A. W. Bowen andD. S. McDarmaid, in “Superplasticity in Aerospace — Aluminium”, edited by R. Pearce and L. Kelly (Cranfield Institute of Technology, Cranfield, UK, 1986) pp. 215–56.
D. J. Field, E. P. Butler andG. M. Scamans, in “Aluminium-Lithium Alloys”, edited by T. H. Sanders Jr and E. A. Starke Jr, (AIME, New York, 1981) pp. 325–346.
D. J. Field, G. M. Scamans andE. P. Butler, in “Aluminium'Lithium II”, edited by T. H. Saunders Jr and E. A. Starke Jr, (AIME, New York, 1983) pp. 657–666.
A. Csanady andJ. Kurthy,J. Mater. Sci. Lett. 16 (1981) 2919.
A. Csanady, D. Marton, I. Geleji-N Eubauer, S. Hofmann andJ. M. Sanz,Corros. Sci. 22 (1982) 689.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Holdway, P., Bowen, A.W. The measurement of lithium depletion in aluminium-lithium alloys using X-ray diffraction. J Mater Sci 24, 3841–3849 (1989). https://doi.org/10.1007/BF01168945
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF01168945