Skip to main content
Log in

Exercise gated planar myocardial perfusion imaging using technetium-99m sestamibi for the diagnosis of coronary artery disease: an alternative to exercise tomographic imaging

  • Original Article
  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract

Single-photon emission tomography (SPET) using technetium-99m labelled myocardial tracers (e.g.99mTc-sestamibi) has become one of the most popular myocardial imaging methods for the diagnosis of coronary artery disease (CAD). This prospective study was designed to evaluate the diagnostic performance of99mTc-sestamibi exercise gated planar myocardial imaging by comparison with both visual and quantitative analyses of SPET. The study was conducted in 115 consecutive patients with known or suspected CAD, including 54 patients with a previous myocardial infarction (MI), referred for exercise testing prior to coronary angiography. Multi-gated planar imaging and SPET were performed after bicycle exercise. The end-diastolic (ED) and SPET images were visually scored (SVi). Myocardial uptake was quantitated on SPET slices using maximum count circumferential profiles (SQu) and defect extent was measured by comparison with gender-matched data sets obtained from 27 controls (<5% likelihood of CAD). CAD was defined as coronary artery stenosis >50% and/or regional wall motion abnormality. The cut-off criteria for positivity of the three procedures were determined from receiver operating characteristic (ROC) curves derived from the data of patients without previous MI. The area under the ROC curves was similar for ED, SVi and SQu. This was confirmed by the analysis of sensitivity performed using the ROC curve-derived cut-off criteria, in patients with or without previous MI. SVi was more sensitive than ED in identifying the diseased vessel(s) (ED: 41% vs SVi: 80%;P<0.0005) but ED was more specific in this respect (ED: 79% vs SVi: 61%;P<0.0005). We conclude that visual analysis of ED images obtained from gated99mTc-sestamibi stress planar imaging is a valuable alternative to SPET imaging for the diagnosis of CAD. SPET is, however, more accurate for the evaluation of the disease extent and localization and therefore remains the method of choice for the assessment of myocardial perfusion.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Kiat H, Maddahi J, Roy LT, Van Train K, Friedman J, Resser K, Berman DS. Comparison of technetium 99m methoxy isobutyl isonitrile and thallium 201 for evaluation of coronary artery disease by planar and tomographic methods.Am Heart J 1989; 117: 1–11.

    PubMed  Google Scholar 

  2. Taillefer R, Lambert R, Dupras G, Gregoire J, Léveillé J, Essiambre R, Phaneuf D-C. Clinical comparison between thallium-201 and Tc-99m-methoxy isobutyl isonitrile (hexamibi) myocardial perfusion imaging for detection of coronary artery disease.Eur J Nucl Med 1989; 15: 280–286.

    PubMed  Google Scholar 

  3. Wackers FJT, Berman DS, Maddahi J Watson DD, Beller GA, Strauss HW, Boucher CA, Picard M, Holman BL, Fridrich R, Inglese E, Delaloye B, Bischof-Delaloye A, Camin L, McKusick K. Technetium-99m hexakis 2-methoxyisobutyl isonitrile: human biodistribution, dosimetry, safety, and preliminary comparison to thallium-201 for myocardial perfusion imaging.J Nucl Med 1989; 30: 301–311.

    PubMed  Google Scholar 

  4. Maisey MN, Lowry A, Bischof-Delaloye A, Fridrich R, Inglese E, Khalil MN, van der Schoot JB. European multi-centre comparison of thallium-201 and technetium-99m methoxyisobutylisonitrile in ischaemic heart disease.Eur J Nucl Med 1990;16:869–872.

    PubMed  Google Scholar 

  5. Verzijlbergen JF, Cramer MJ, Niemeyer MG, Ascoop CAPL, Van der Wall EE, Pauwels EKJ.99Tcm-Sestamibi for planar myocardial perfusion imaging; not as ideal as the physical properties.Nucl Med Commun 1991; 12: 381–391.

    PubMed  Google Scholar 

  6. Fintel DJ, Links JM, Brinker JA, Frank TL, Parker M, Becker LC. Improved diagnostic performance of exercise thallium201 single photon emission computerized tomography over planar imaging in the diagnosis of coronary artery disease: a receiver operating characteristic analysis.J Am Coll Cardiol 1989;13:600–612.

    PubMed  Google Scholar 

  7. Garcia EV, Van Train K, Maddahi J, Prigent F, Friedman J, Areeda J, Waxman A, Berman D. Quantification of rotational thallium-201 myocardial tomography.J Nucl Med 1985; 26: 17–26.

    PubMed  Google Scholar 

  8. Kahn JK, McGhie I, Akers MS, Sills MN, Faber TL, Kulkarni PV, Willerson JT, Corbett JR. Quantitative rotational tomography with 201T1 and 99'nTc 2-methoxy-isobutyl-isonitrile. A direct comparison in normal individuals and patients with coronary artery disease.Circulation 1989; 79: 1282–1293.

    PubMed  Google Scholar 

  9. Maddahi J, Kiat H, Van Train KF, Prigent F, Friedman J, Garcia EV, Alazraki N, DePuey EG, Nichols K, Berman DS. Myocardial perfusion imaging with technetium-99m sestamibi SPECT in the evaluation of coronary artery disease.Am J Cardiol 1990; 66: 55E-62E.

    PubMed  Google Scholar 

  10. Mahmarian JJ, Boyce TM, Goldberg RK, Cocanougher MK, Roberts R, Verani MS. Quantitative exercise thallium-201 single photon emission computed tomography for the enhanced diagnosis of ischemic heart disease.J Am Coll Cardiol 1990; 15:318–329.

    PubMed  Google Scholar 

  11. Kiat H, Van Train KF, Maddahi J, Corbett JR, Nichols K, McGhie Al, Akers MS, Friedman JD, Roy L, Berman DS. Development and prospective application of quantitative 2-day stress-rest Tc-99m methoxyisobutyl isonitrile SPECT for the diagnosis of coronary artery disease.Am Heart J 1990: 120: 1255–1266.

    PubMed  Google Scholar 

  12. Merz R, Maddahi J, Roy L, Berman DS. Gated RP-30 perfusion study after stress predicts myocardial viability.J Am Coll Cardiol 1987; 9: 27A.

    Google Scholar 

  13. Kahn JK, McGhie I, Faber TL, Sills MN, Akers MS, Willerson JT, Corbett JR. Assessment of myocardial viability with technetium-99m 2-methoxy isobutyl isonitrile (MIBI) and gated tomography in patients with coronary artery disease.J Am Coll Cardiol 1989; 13: 31A.

    Google Scholar 

  14. Avery PG, Hudson NM, Hubner PJB. Gated technetium-99m methoxyisobutylisonitrile perfusion imaging.Int J Cardiol 1992;35:227–234.

    PubMed  Google Scholar 

  15. Smith WH, Watson DD. Technical aspects of myocardial planar imaging with technetium-99m sestamibi.Am J Cardiol 1990;66:16E-22E.

    PubMed  Google Scholar 

  16. Maisey MN, Mistry R, Sowton E. Planar imaging techniques used with technetium-99m sestamibi to evaluate chronic myocardial ischemia.Am J Cardiol 1990; 66: 47E-54E.

    PubMed  Google Scholar 

  17. DePuey EG, Garcia EV. Optimal specificity of thallium-201 SPECT through recognition of imaging artifacts.J Nucl Med 1989;30:441–449.

    PubMed  Google Scholar 

  18. Diamond GA, Forrester JS. Analysis of probability as an aid in the clinical diagnosis of coronary artery disease.N Engl J Med 1979; 300: 1350–1358.

    PubMed  Google Scholar 

  19. Melin JA, Piret LP, Vanbutsele RJM, Rousseau MF, Cosyns J, Brasseur LA, Beckers C, Detry J-MR. Diagnostic value of exercise electrocardiography and thallium myocardial scintigraphy in patients without previous myocardial infarction: a Bayesian approach.Circulation 1981; 63: 1019–1024.

    PubMed  Google Scholar 

  20. Melin JA, De Coster PM, Renkin J, Detry J-MR, Beckers C, Col J. Effect of intracoronary thrombolytic therapy on exercise-induced ischemia after acute myocardial infarction.Am J Cardiol 1985; 56: 705–711.

    PubMed  Google Scholar 

  21. Garcia E, Maddahi J, Berman D, Waxman A. Space/time quantitation of thallium-201 myocardial scintigraphy.J Nucl Med 1981; 22: 309–317.

    PubMed  Google Scholar 

  22. Metz CE. Basic principles of ROC curves analysis.Semin Nucl Med 1978; 8: 283–298.

    PubMed  Google Scholar 

  23. Hanley JA, McNeil BJ. A method comparing the areas under receiver operating characteristic curves derived from the same cases.Radiology 1983; 148: 839–843.

    PubMed  Google Scholar 

  24. Iskandrian AS, Heo J, Kong B, Lyons E. Effect of exercise level on the ability of thallium-201 tomographic imaging in detecting coronary artery disease: analysis of 461 patients.J Am Coll Cardiol 1989; 14: 1477–1486.

    PubMed  Google Scholar 

  25. McKillop JH, Fawcett HD, Baumert JE, McDougall IR, DeBuslc RF, Harrison DC, Goris ML. ECG gating of thallium-201 myocardial images: effect of detection of ischaemic heart disease.J Nucl Med 1981; 22: 219–225.

    PubMed  Google Scholar 

  26. Valette H, Bourguignon MH, Le Guludec D, Merlet P, Dove PJ, Kiger J-P, Slama M, Motté G, Raynaud C, Syrota A. ECG gated thallium 201 myocardial images: value in detecting multivessel disease in patients on anti-anginal therapy 1–3 months after myocardial infarction.Eur J Nucl Med 1988; 13: 551–556.

    PubMed  Google Scholar 

  27. Hurwitz GA, Schwab ME, MacDonald AC, Driedger AA. Quantitative analysis of myocardial ischaemia on end-diastolic thallium-201 perfusion images.Eur J Nucl Med 1990; 17: 257–263.

    PubMed  Google Scholar 

  28. Alderson PO, Wagner HN Jr, Gomez-Moeiras JJ, Rehn TG, Becker LC, Douglas KH, Manspeaker HF, Schindledecker GR. Simultaneous detection of myocardial perfusion and wall motion abnormalities by cinematic T1201 imaging.Radiology 1978;127:531–533.

    PubMed  Google Scholar 

  29. Hamilton GW, Narahara KA, Trobaugh GB, Ritchie JL, Williams DL. Thallium-201 myocardial imaging: characterization of the ECG-synchronized images.J Nucl Med 1978; 19: 1103–1110.

    PubMed  Google Scholar 

  30. Gewirtz H, Grötte GJ, Strauss HW, O'Keefe DD, Akins CW, Daggett WM, Pohost GM. The influence of left ventricular volume and wall motion on myocardial images. Circulation 1979;6:1172–1177.

    Google Scholar 

  31. Sinusas AJ, Vitols PJ, Fetterman RC, Allam AH, Maniawski PJ, Zaret BL, Wackers FJT. Ischemic myocardial dysfunction creates artifactual perfusion defects with technetium-99m sestamibi.J Nucl Med 1991; 32: 909.

    PubMed  Google Scholar 

  32. Majeed Q, Najm YC, Maisey MN. Improving diagnostic quality with end-diastolic 99Tcm hexakis 2-methoxyisobutylisonitrile images.Nucl Med Commun 1989; 10: 210–211.

    Google Scholar 

  33. Li QS, Frank TL, Franceschi D, Wagner HN Jr, Becker LC. Technetium-99m methoxyisobutyl isonitrile (RP30) for quantification of myocardial ischemia and reperfusion in dogs.J Nucl Med 1988; 29: 1539–1548.

    PubMed  Google Scholar 

  34. Maddahi J, Rozanski A, Becerra A, Murphy F, Diamond G, Swan HJC, Berman D. Patients with a calculated very low likelihood of coronary artery disease: an alternative population of cardiac normals.Circulation 1982; 66(Suppl II]: 62.

    Google Scholar 

  35. Baillet GY, Mena IG, Kuperus JH, Robertson JM, French WJ. Simultaneous technetium-99m MIBI angiography and myocardial perfusion imaging.J Nucl Med 1989; 30: 38–44.

    PubMed  Google Scholar 

  36. Marcassa C, Marzullo P, Parodi O, Sambuceti G, L'Abatte A. A new method for noninvasive quantitation of segmental myocardial wall thickening using technetium-99m 2-methoxy-isobutyl-isonitrile scintigraphy: results in normal subjects.J Nucl Med 1990; 31: 173–177.

    PubMed  Google Scholar 

  37. Sinusas AJ, Allam AH, Maniawski PJ, Wackers FIT, Vitols PJ, Harnish G, Zaret BL. ECG-gated imaging with Tc99msestamibi provides an accurate quantitative assessment of regional myocardial thickening: experimental validation in an intact animal model.J Nucl Med 1991; 32: 957.

    Google Scholar 

  38. Mannting F, Morgan-Mannting MG. Gated SPELT with technetium-99m-sestamibi for assessment of myocardial perfusion abnormalities.J Nucl Med 1993; 34: 601–608.

    PubMed  Google Scholar 

  39. Berman DS, Kiat HS, Van Train KF, Germano G, Maddahi J, Friedman JD. Myocardial perfusion imaging with technetium99m-sestamibi: comparative analysis of available protocols.J Nucl Med 1994; 35: 681–688.

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Jamar, F., Topcuoglu, R., Cauwe, F. et al. Exercise gated planar myocardial perfusion imaging using technetium-99m sestamibi for the diagnosis of coronary artery disease: an alternative to exercise tomographic imaging. Eur J Nucl Med 22, 40–48 (1995). https://doi.org/10.1007/BF00997246

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00997246

Key words

Navigation