Abstract

A contour detection algorithm for cerebral studies, using the method of Tomitani, has been implemented on a single-photon emission tomographic (SPET) system. It is based on the detetion by threshold of the brain edge in the sinogram and does not depend on the reconstruction algorithm. Thirteen normal subjects underwent an examination on both computed tomography (CT) and SPET using a head holder to ensure the reproducibility of the positioning. The CT scan contour of the brain was drawn manually according to the brain parenchyma limits. The SPET brain contour was obtained by use of the Tomitani algorithm after the threshold had been determined on an active cylindrical phantom. Using a threshold of 37% of the maximum uptake, the length of the contour as well as the area obtained with SPET and CT were not found to be statistically different. The method of Tomitani, which is simpler and faster then previous methods, provides contours which superimpose very well with CT scan images. Application to patients with unilateral pathological defects is possible by requiring that the contour is symmetrical.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. De Roo M, Mortelmans L, Devos P, et al. Clinical experience with Tc-99m HM-PAO high resolution SPECT of the brain in patients with cerebrovascular accidents.Eur J Nucl Med 1989: 15:9–15.

    Google Scholar 

  2. Smith FW, Donald RT, Morris AJ, Sharp PF, Gemmell HG. The study of regional cerebral flood flow in stroke patients using technetium 99m HMPAO.Br J Radiol 1988: 61:26–29.

    Google Scholar 

  3. Holman BL, Johnson KA, Gerarda B, Carvalho PA, Saltim A. The scintigraphic appearance of Alzheimer's disease: a prospective study using technetium-99m-HMPAO Spect.J Nucl Med 1992: 33:181–185.

    Google Scholar 

  4. Neary D, Snowden JS, Shield RA, et al. Single photon emission tomography using99mTc-HM-PAO in the investigation of dementia.J Neurol Neurosurg Psychiatry 1987: 50:1101–1109.

    Google Scholar 

  5. Waldemar G, Hasselbach SG, Andersen AR, et al.99mTc-d,l-,HMPAO and SPECT of the brain in normal aging.J Cereb Blood Flow Metab 1991: 11:508–521.

    Google Scholar 

  6. Andersen AR, Friberg H, Knudsen KBM, et al. Extraction of (Tc99m)-d-l-HM-PAO across the blood-brain barrier.J. Cereb Blood Flow Metab 1988: 8:544–551.

    Google Scholar 

  7. Jaszczak RJ, Coleman RE, Whitehead FR. Physical factors affecting quantitative measurements using camera-based single photon emission computed tomography (SPECT).IEEE Trans Nucl Sci 1981: NS-28:69–80.

    Google Scholar 

  8. Tomitani T. An edge detection algorithm for attenuation correction in emission CT.IEEE Trans Nucl Sci 1987: NS-34:309–312.

    Google Scholar 

  9. Bergström M, Litton J, Eriksson L, Bohm C, Blomqvist G. Determination of object contour from projections for attenuation correction in cranial positron emission tomography.J Comput Assist Tomogr 1982: 6:365–372.

    Google Scholar 

  10. Hosoba M, Wani H, Toyama H, Murata H, Tanaka E. Automated body contour detection in SPECT: effects on quantitative studies.J Nucl Med 1986: 27:1184–1191.

    Google Scholar 

  11. Evans AC, Beil C, Marrett S, Thompson CJ, Hakim A. Anatomical-functional correlation using an adjustable MRI-based region of interest atlas with positron emission tomography.J Cereb Blood Flow Metab 1988: 8:513–530.

    Google Scholar 

  12. Friedman J. Data analysis for high energy particle physics.CERN Report 74-23. Proceedings of the CERN School of Computing, Godoysund, Norway, 1974.

  13. Scheid F.Theory and problems of numerical analysis. Schaum's Outline Series. New York: McGraw-Hill, 1968.

    Google Scholar 

  14. Michel C, Bol A, De Volder AG, Goffinet AM. Online brain attenuation correction in PET: towards a fully automated data handling in a clinical environment.Eur J Nucl Med 1989: 15:712–718.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

van Elmbt, L.R., Keyeux, A. & Demeure, R. Validation of automated brain contour determination in normal and abnormal cerebral single-photon emission tomography. Eur J Nucl Med 22, 537–542 (1995). https://doi.org/10.1007/BF00817278

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00817278

Key words

Navigation