Conclusions
-
1.
Hydrogenation of commerical titanium VT1-0 was not observed in hydrogen at 150 MPa pressure and 25°C under the conditions of uniform compression, or tensile stress up to 0.9-σ0.2 produced by internal pressure of the gas.
-
2.
At 100°C, under a hydrogen pressure of 109 MPa, hydrogenation of titanium occurred under the conditions of both uniform compression and, in the case of tubular speciments, under internal pressure. The rate of hydrogenation of the tubular specimens was appreciably higher.
-
3.
Titanium hydride forms in the subsurface layers of the tubular specimens after testing at 100°C.
Similar content being viewed by others
Literature cited
P. V. Gel'd, R. A. Ryabov, and E. S. Kodes, Hydrogen and Imperfections in the Structure of Metals [in Russian], Metallurgiya, Moscow (1979).
J. L. Waisman, G. Sines, and L. B. Robinson, Met. Trans.,4, No. 1, 291–302 (1973).
D. N. Williams, B. G. Koehl, and E. S. Bartlett, J. Less Common Metals,19, No. 4, 385–398 (1969).
Yu. I. Archakov, T. D. Aleferenko, and Yu. V. Telegin, "Resistance of titanium VT1-0 to hydrogenation at room temperature under a pressure of 150 MPa," Fiz.-Khim. Mekh. Mater., No. 5, 118–119 (1984).
Additional information
Scientific-Production Organization "Lenneftekhim." Translated from Metallovedenien i termicheskaya Obrabotka Metallov, No. 2, pp. 35–36, February, 1991.
Rights and permissions
About this article
Cite this article
Aleferenko, T.D., Archakov, Y.I. Effect of stresses on the absorption of hydrogen by titanium. Met Sci Heat Treat 33, 141–144 (1991). https://doi.org/10.1007/BF00773892