Skip to main content
Log in

Die Korrektur der Sekundärfluorescenz in der Röntgenspektrometrie

The correction of secondary fluorescence in X-ray spectrometry

  • Originalarbeiten
  • Published:
Fresenius' Zeitschrift für analytische Chemie Aims and scope Submit manuscript

Summary

The Eq. (3) \(C_i = a + bI_i + I_i \Sigma k_{ij} C_j \) was directly derived from the theory and does not contain the correction of secondary fluorescence proposed by the authors of [3] with their semi-empirical Eq. (4) \(C_i = p + qI_i + I_i \Sigma A_{ij} C_j + I_i \Sigma \frac{{B_{ik} C_k }}{{100 + C_i }}\) Therefore, it was of interest to test the efficiency of Eq. (4) in comparison with Eq. (3), the average analysis error serving as test criterion.

The application to theoretically calculated and empirically measured Fe-Cr-Ni-systems and to mixtures of metal oxides resulted in a very small superiority of Eq. (4) to Eq. (3). Since Eq. (4) is mathematically more complicated than Eq. (3) the latter seems to be more suitable for practice.

Zusammenfassung

Die unmittelbar aus der Theorie abgeleitete Gl. (3) \(C_i = a + bI_i + I_i \Sigma k_{ij} C_j \) enthält keine explizite Korrektur der Sekundärfluorescenz, wie sie mit Gl. (4) \(C_i = p + qI_i + I_i \Sigma A_{ij} C_j + I_i \Sigma \frac{{B_{ik} C_k }}{{100 + C_i }}\) in [3] vorgeschlagen wurde. Es war daher von Interesse, die Wirksamkeit der Gl. (4) im Vergleich mit Gl. (3) zu überprüfen, wobei der durchschnittliche Analysenfehler unbekannter Proben als Prüfkriterium diente.

Die Anwendung auf theoretisch berechnete und praktisch gemessene Fe-Cr-Ni-Proben und auf Gemische von Metalloxiden ergab eine sehr geringe Überlegenheit von Gl. (4) über Gl. (3). Da erstere jedoch rechentechnisch komplexer aufgebaut ist, erscheint Gl. (3) als für die Praxis geeigneter.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  1. Bertin EP (1970) Principles and practice of X-ray spectrometric analysis. Plenum Press, New York London

    Google Scholar 

  2. Plesch R (1982) Auswerten und Prüfen in der Röntgenspektrometrie. G-I-T Verlag Ernst Giebeler, Darmstadt

    Google Scholar 

  3. Rasberry SD, Heinrich KFJ (1974) Anal. Chem 46:81

    Google Scholar 

  4. Plesch R (1979) X-Ray Spectrom 8:114

    Google Scholar 

  5. Plesch R (1981) X-Ray Spectrom 10:193

    Google Scholar 

  6. Plesch R (1981) Fresenius Z Anal Chem 305:358

    Google Scholar 

  7. Plesch R (1977) Fresenius Z Anal Chem 284:107

    Google Scholar 

  8. Shiraiwa T, Fujino N (1967) Bull Chem Soc Jpn 40:2289

    Google Scholar 

  9. Stephenson DA (1971) Anal Chem 43:310

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Plesch, R. Die Korrektur der Sekundärfluorescenz in der Röntgenspektrometrie. Z. Anal. Chem. 321, 748–752 (1982). https://doi.org/10.1007/BF00466945

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00466945

Navigation